ترغب بنشر مسار تعليمي؟ اضغط هنا

A robust floating nanoammeter

54   0   0.0 ( 0 )
 نشر من قبل Jony Hudson
 تاريخ النشر 2008
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A circuit capable of measuring nanoampere currents while floating at voltages up to at least 25kV is described. The circuit relays its output to ground potential via an optical fiber. We particularly emphasize the design and construction techniques which allow robust operation in the presence of high voltage spikes and discharges.


قيم البحث

اقرأ أيضاً

FASPAX (Fermi-Argonne Semiconducting Pixel Array X-ray detector) is being developed as a fast integrating area detector with wide dynamic range for time resolved applications at the upgraded Advanced Photon Source (APS.) A burst mode detector with in tended $mbox{13 $MHz$}$ image rate, FASPAX will also incorporate a novel integration circuit to achieve wide dynamic range, from single photon sensitivity to $10^{text{5}}$ x-rays/pixel/pulse. To achieve these ambitious goals, a novel silicon sensor design is required. This paper will detail early design of the FASPAX sensor. Results from TCAD optimization studies, and characterization of prototype sensors will be presented.
135 - Xiang Zhang , Liang Hu , Xue Deng 2021
Optical fibers have been recognized as one of the most promising host material for high phase coherence optical frequency transfer over thousands of kilometers. In the pioneering work, the active phase noise cancellation (ANC) technique has been wide ly used for suppressing the fiber phase noise introduced by the environmental perturbations, in which an ideal phase detector with high resolution and unlimited detection range is needed to extract the fiber phase noise, in particular for noisy fiber links. We demonstrate the passive phase noise cancellation (PNC) technique without the need of phase detector could be preferable for noisy fiber links. To avoid the effect of the radio frequency (RF) from the time base at the local site in the conventional active or passive phase noise cancellation techniques, here we introduce a fiber-pigtailed acousto-optic modulator (AOM) with two diffraction order outputs (0 and +1 order) with properly allocating the AOM-driving frequencies allowing to cancel the time base effect. Using this technique, we demonstrate transfer of coherent light through a 260 km noisy urban fiber link. The results show the effect of the RF reference can be successfully removed. After being passively compensated, {we demonstrate a fractional frequency instability of $4.9times10^{-14}$ at the integration time of 1 s and scales down to $10^{-20}$ level at 10,000 s in terms of modified Allan deviation over the 260 km noisy urban fiber link}. The frequency uncertainty of the retrieved light after transferring through this noise-compensated fiber link relative to that of the input light achieves $(0.41pm4.7)times10^{-18}$. The proposed technique opens a way to a broad distribution of an ultrastable frequency reference with high coherence without any effects coming from the RF reference and enables a wide range of applications beyond metrology over fiber networks.
105 - L. Moleri , F.D. Amaro , L. Arazi 2016
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. De tection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9${Omega}cm resistive plate resulted in a completely discharge-free operation also in intense pion beams. The efficiency remained essentially constant at 98-99% up to fluxes of $sim$10$^4$Hz/cm$^2$, dropping by a few % when approaching 10$^5$ Hz/cm$^2$. These results pave the way towards cost-effective, robust, efficient, large-scale detectors for a variety of applications in future particle, astro-particle and applied fields. A potential target application is digital hadron calorimetry.
100 - G. Blaj , G. Haller , C. J. Kenney 2019
Pixel detectors typically display pixel-to-pixel gain variation of a few percent which result in reduced spectroscopic performance. We have developed a calibration method which relies on cross-correlating histograms of many pixel pairs and obtaining large sets of relative shifts. These were subsequently used to calculate absolute pixel shifts and corresponding pixel gains. We demonstrate that this method yields stable gain calibration maps with an order of magnitude less statistics than required by typical approaches. Finally, we demonstrate the accuracy of the method by comparing with gain maps obtained with good statistics and monochromatic radiation at a synchrotron beamline.
465 - J.C. Zamora , G.F. Fortino 2020
A tracking algorithm based on consensus-robust estimators was implemented for the analysis of experiments with time-projection chambers. In this work, few algorithms beyond RANSAC were successfully tested using experimental data taken with the AT-TPC , ACTAR and TexAT detectors. The present tracking algorithm has a better inlier-outlier detection than the simple sequential RANSAC routine. Modifications in the random sampling and clustering were included to improve the tracking efficiency. Very good results were obtained in all the test cases, in particular for fitting short tracks in the detection limit.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا