ترغب بنشر مسار تعليمي؟ اضغط هنا

Bulk Etch Rate Measurements and Calibrations of Plastic Nuclear Track Detectors

148   0   0.0 ( 0 )
 نشر من قبل Miriam Giorgini
 تاريخ النشر 2006
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

New calibrations of CR39 and Makrofol nuclear track detectors have been obtained using 158 A GeV Pb (82+) and In (49+) ions; a new method for the bulk etch rate determination, using both cone height and base diameter measurements was developed. The CR39 charge resolution based on the etch-pit base area measurement is adequate to identify nuclear fragments in the interval 7 <= Z/beta <= 49. For CR39 the detection threshold is at REL~50 MeV cm^2/g, corresponding to a nuclear fragment with Z/beta~7. Base cone area distributions for Makrofol foils exposed to Pb (82+) ions have shown for the first time all peaks due to nuclear fragments with Z > 50; the distribution of the etched cone heights shows well separated individual peaks for Z/beta = 78 - 83 (charge pickup). The Makrofol detection threshold is at REL 2700 MeV cm^2/g, corresponding to a nuclear fragment with Z/beta~50.

قيم البحث

اقرأ أيضاً

We report on the measurements of the total charge changing fragmentation cross sections in high-energy nucleus-nucleus collisions using Fe, Si and Pb incident ions. Several stacks of CR39 nuclear track detectors with different target combinations wer e exposed at normal incidence to high energy accelerator beams to integrated densities of about 2000 ions/cm^2. The nuclear track detector foils were chemically etched, and ion tracks were measured using an automatic image analyzer system. The cross section determination is based on the charge identification of beam ions and their fragments and on the reconstruction of their path through the stacks.
Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $times$ 50 $times$ 3$^{t}$ mm$^3 $ and 80 $times$ 100 $times$ 3$^{t}$ mm$^3$ have been set up at the external target facility (ETF), Institute of Modern Physics. Their time, energy and position responses are measured with $^{18}$O primary beam at 400 MeV/nucleon. After the off-line walk-effect and position corrections, the time resolution of the two detectors are determined to be 27 ps ($sigma$) and 36 ps ($sigma$), respectively. Both detectors have nearly the same energy resolution of 3$%$ ($sigma$) and position resolution of 2 mm ($sigma$). The detectors have been used successfully in nuclear reaction cross section measurements, and will be be employed for upgrading RIBLL2 beam line at IMP as well as for the high energy branch at HIAF.
In this work we propose the application of a radiation damage model based on the introduction of deep level traps/recombination centers suitable for device level numerical simulation of radiation detectors at very high fluences (e.g. 1{div}2 10^16 1- MeV equivalent neutrons per square centimeter) combined with a surface damage model developed by using experimental parameters extracted from measurements from gamma irradiated p-type dedicated test structures.
The effects induced by muons with very low energies are usually neglected. In fact, they could represent a source of radioactive background due to capture processes in different materials, which in most of cases produce radioactive isotopes, and thus they must be taken into account. Plastic track detectors have been used in the present paper to measure the ratio between the vertical and horizontal components of the flux of very low energy terrestrial muons at ground level. The data have been collected during 160 days.
Horizon-T, a modern Extensive Air Showers (EAS) detector system, is constructed at Tien Shan high-altitude Science Station of Lebedev Physical Institute of the Russian Academy of Sciences at approximately 3340 meters above the sea level in order to s tudy in the energy range above 10^16 eV coming from a wide range of zenith angles (0 - 85 degrees). The detector includes eight charged particle detection points and a Vavilov-Cherenkov radiation detector. Each charged particle detector response is calibrated using single MIP (minimally ionizing particle) signal. The details of this calibration are provided in this article. This note is valid for data before March 2017 and will not be updated following any detector calibration and configuration changes as a large upgrade has been implemented.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا