ترغب بنشر مسار تعليمي؟ اضغط هنا

Time and position distributions in large volume spherical scintillation detectors

55   0   0.0 ( 0 )
 نشر من قبل Gioacchino Ranucci
 تاريخ النشر 2006
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Large spherical scintillation detectors are playing an increasingly important role in experimental neutrino physics studies. From the instrumental point of view the primary signal response of these set-ups is constituted by the time and amplitude of the anode pulses delivered by each individual phototube following a particle interaction in the scintillator. In this work, under some approximate assumptions, we derive a number of analytical formulas able to give a fairly accurate description of the most important timing features of these detectors, intended to complement the more complete Monte Carlo studies normally used for a full modelling approach. The paper is completed with a mathematical description of the event position distributions which can be inferred, through some inference algorithm, starting from the primary time measures of the photomultiplier tubes.

قيم البحث

اقرأ أيضاً

59 - L. Pereira 2015
Position sensitive detectors based on gaseous scintillation proportional counters with Anger-type readout are being used in several research areas such as neutron detection, search for dark matter and neutrinoless double beta decay. Design and optimi zation of such detectors are complex and time consuming tasks. Simulations, while being a powerful tool, strongly depend on the light transport models and demand accurate knowledge of many parameters, which are often not available. Here we describe an alternative approach based on the experimental evaluation of a detector using an isotropic point-like light source with precisely controllable light emission properties, installed on a 3D positioning system. The results obtained with the developed setup at validation conditions, when the scattered light is strongly suppressed, show good agreement with simulations.
392 - P. Juyal , K. L. Giboni , X. Ji 2019
The charge read out of a LXe detector via Proportional Scintillation in the liquid phase was first realized by the Waseda group 40 years ago, but at that time the technical challenges were overwhelming. Although the tests were successful, this method was finally discarded and eventually nearly forgotten. For present day large LXe Dark Matter detectors, this approach was not even considered. Instead the Dual Phase technology was selected despite many limitations and challenges. In two independent studies the groups from Columbia University and Shanghai Jiao Tong University reevaluated Proportional Scintillation in the liquid phase. Both established the merits for very large LXe detectors, but the Columbia group also encountered apparent limitations, namely the shadowing of the light by the anode wires and a dependence of the pulse shape on the drift path of the electrons in the anode region. The discrepancies between the two studies, however, are not intrinsic to the technique, but a direct consequence of the chosen geometry. Taking the geometrical differences into account the results match without ambiguity. They also agree with the original results from the Waseda group. With the technical problems solved, the path is now open to use this method in future large LXe TPCs.
Large volume Liquid Argon Time Projection Chambers (LAr-TPC) are used and proposed for neutrino physics and rare event search. Most of these detectors make use of the scintillation light of liquid argon for trigger purposes. Two different approaches can be adopted to provide these detectors with an effective trigger system, relying upon analog or digital processing of signal coming from photodetectors, like photomultiplier tubes or silicon photomultipliers. Each method presents advantages and drawbacks, so the implementation of a hybrid solution can benefit from both approaches. To this purpose, an innovative electronic board prototype has been designed and proposed for the use in large volume LAr-TPC detectors.
115 - Bjorn S. Wonsak 2018
Unsegmented, large-volume liquid scintillator (LS) neutrino detectors have proven to be a key technology for low-energy neutrino physics. The efficient rejection of radionuclide background induced by cosmic muon interactions is of paramount importanc e for their success in high-precision MeV neutrino measurements. We present a novel technique to reconstruct GeV particle tracks in LS, whose main property, the resolution of topological features and changes in the differential energy loss $mathrm{d}E/mathrm{d}x$, allows for improved rejection strategies. Different to common track reconstruction approaches, our method does not rely on concrete track / topology hypotheses. Instead, based on a reference point in space and time, the observed distribution of photon arrival times at the photosensors and the detectors characteristics in terms of photon production, propagation and detection (optical model), it reconstructs the voxelized distribution of optical photon emissions. Techniques from three-dimensional data analysis can then be applied to extract parameters describing the topology, e.g., the direction of a track. We performed a first performance evaluation of our method using single muon events with up to $10,mathrm{GeV}$ from a Geant4 simulation of the LENA detector. The current results indicate that our approach is competitive with existing reconstruction methods -- although its full potential has not yet been exploited. We also remark on other detector technologies in astroparticle physics as well as applications in medical imaging that could benefit from the fundamental ideas of our method.
A new type of radiation detector based on a spherical geometry is presented. The detector consists of a large spherical gas volume with a central electrode forming a radial electric field. Charges deposited in the conversion volume drift to the centr al sensor where they are amplified and collected. We introduce a small spherical sensor located at the center acting as a proportional amplification structure. It allows high gas gains to be reached and operates in a wide range of gas pressures. Signal development and the absolute amplitude of the response are consistent with predictions. Sub-keV energy threshold with good energy resolution is achieved. This new concept has been proven to operate in a simple and robust way and allows reading large volumes with a single read-out channel. The detector performance presently achieved is already close to fulfill the demands of many challenging projects from low energy neutrino physics to dark matter detection with applications in neutron, alpha and gamma spectroscopy.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا