ترغب بنشر مسار تعليمي؟ اضغط هنا

Demonstration of a Cold Atom Fountain Electron Electric Dipole Moment Experiment

95   0   0.0 ( 0 )
 نشر من قبل Harvey Gould
 تاريخ النشر 2006
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A Cs fountain electron electric dipole moment (EDM) experiment using electric-field quantization is demonstrated. With magnetic fields reduced to 200 pT or less, the electric field lifts the degeneracy between hyperfine levels of different|mF| and, along with the slow beam and fountain geometry, suppresses systematics from motional magnetic fields. Transitions are induced and the atoms polarized and analyzed in field-free regions. The feasibility of reaching a sensitivity to an electron EDM of 2 x 10 exp(-50) C-m [1.3 x 10 exp(-29) e-cm] in a cesium fountain experiment is discussed.

قيم البحث

اقرأ أيضاً

123 - C. Abel , S. Afach , N. J. Ayres 2019
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiments magneti c field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser drives all magnetometers that are located in a high-vacuum chamber, with a selection of the sensors mounted on a high-voltage electrode. We describe details of the Cs sensors construction and modes of operation, emphasizing the accuracy and sensitivity of the magnetic field readout. We present two applications of the magnetometer array directly beneficial to the nEDM experiment: (i) the implementation of a strategy to correct for the drift of the vertical magnetic field gradient and (ii) a procedure to homogenize the magnetic field. The first reduces the uncertainty of the new nEDM result. The second enables transverse neutron spin relaxation times exceeding 1500 s, improving the statistical sensitivity of the nEDM experiment by about 35% and effectively increasing the rate of nEDM data taking by a factor of 1.8.
The Standard Model (SM) of particle physics fails to explain dark matter and why matter survived annihilation with antimatter following the Big Bang. Extensions to the SM, such as weak-scale Supersymmetry, may explain one or both of these phenomena b y positing the existence of new particles and interactions that are asymmetric under time-reversal (T). These theories nearly always predict a small, yet potentially measurable ($10^{-27}$-$10^{-30}$ $e$ cm) electron electric dipole moment (EDM, $d_e$), which is an asymmetric charge distribution along the spin ($vec{S}$). The EDM is also asymmetric under T. Using the polar molecule thorium monoxide (ThO), we measure $d_e = (-2.1 pm 3.7_mathrm{stat} pm 2.5_mathrm{syst})times 10^{-29}$ $e$ cm. This corresponds to an upper limit of $|d_e| < 8.7times 10^{-29}$ $e$ cm with 90 percent confidence, an order of magnitude improvement in sensitivity compared to the previous best limits. Our result constrains T-violating physics at the TeV energy scale.
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}ecdot$cm by using polarized magic momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the scale of 3000~TeV.
313 - C. Abel , N. J. Ayres , G. Ban 2021
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-ma gnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the largest systematic effect of this measurement. To evaluate and correct that effect, offline measurements of the field non-uniformity were performed during mapping campaigns in 2013, 2014 and 2017. We present the results of these campaigns, and the improvement the correction of this effect brings to the neutron electric dipole moment measurement.
Experimental searches for the electron electric dipole moment, $d_e$, probe new physics beyond the Standard Model. Recently, the ACME Collaboration set a new limit of $|d_e| <1.1times 10^{-29}$ $ecdot textrm{cm}$ [Nature $textbf{562}$, 355 (2018)], c onstraining time reversal symmetry (T) violating physics in the 3-100 TeV energy scale. ACME extracts $d_e$ from the measurement of electron spin precession due to the thorium monoxide (ThO) molecules internal electric field. This recent ACME II measurement achieved an order of magnitude increased sensitivity over ACME I by reducing both statistical and systematic uncertainties in the measurement of the electric dipole precession frequency. The ACME II statistical uncertainty was a factor of 1.7 above the ideal shot-noise limit. We have since traced this excess noise to timing imperfections. When the experimental imperfections are eliminated, we show that shot noise limit is attained by acquiring noise-free data in the same configuration as ACME II.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا