ترغب بنشر مسار تعليمي؟ اضغط هنا

O VI and H_2 Lines in Sunspots

80   0   0.0 ( 0 )
 نشر من قبل Nicolas Labrosse
 تاريخ النشر 2006
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Nicolas Labrosse




اسأل ChatGPT حول البحث

Sunspots are locations on the Sun where unique atmospheric conditions prevail. In particular, the very low temperatures found above sunspots allow the emission of H_2 lines. In this study we are interested in the radiation emitted by sunspots in the O VI lines at 1031.96 A and 1037.60 A. We use SOHO/SUMER observations of a sunspot performed in March 1999 and investigate the interaction between the O VI lines and a H_2 line at 1031.87 A found in the Werner band. The unique features of sunspots atmospheres may very well have important implications regarding the illumination of coronal O+5 ions in the low corona, affecting our interpretation of Doppler dimming diagnostics.

قيم البحث

اقرأ أيضاً

We critically examine the recent claimed detection of Raman scattered O VI at around 6830AA in the iron curtain stage spectra of the classical CO nova V339 Del. The observed line variations are compatible in profile and timing of emission line streng th with an excited state transition of neutral carbon. Line formation in classical nova ejecta is physically very different from that in symbiotic binaries, in which the O VI emission line is formed within the wind of the companion red giant at low differential velocity. The ejecta velocity and density structure prevent the scattering from producing analogous features. There might , however, be a broadband spectropolarimetric signature of the Raman process and also Rayleigh scattering at some stage in the expansion. We show that the neutral carbon spectrum, hitherto under-exploited for novae, is especially useful as a probe of the structure of the ejecta during the early, optically thick stages of the expansion
Using the Texas Echelon Cross Echelle Spectrograph (TEXES) we mapped emission in the H_2 v = 0-0 S(1) and S(2) lines toward the Orion Bar PDR at 2 resolution. We also observed H_2 v = 0-0 S(4) at selected points toward the front of the PDR. Our maps cover a 12 by 40 region of the bar where H_2 ro-vibrational lines are bright. The distributions of H_2 0-0 S(1), 0-0 S(2), and 1-0 S(1) line emission agree in remarkable detail. The high spatial resolution (0.002 pc) of our observations allows us to probe the distribution of warm gas in the Orion Bar to a distance approaching the scale length for FUV photon absorption. We use these new observational results to set parameters for the PDR models described in a companion paper (Draine et al. 2005, in prep). The best-fit model can account for the separation of the H_2 emission from the ionization front and the intensities of the ground state rotational lines as well as the 1-0 S(1) and 2-1 S(1) lines. This model requires significant adjustments to the commonly used values for the dust UV attenuation cross section and the photoelectric heating rate.
Opacity is a property of many plasmas, and it is normally expected that if an emission line in a plasma becomes optically thick, its intensity ratio to that of another transition that remains optically thin should decrease. However, radiative transfe r calculations undertaken both by ourselves and others predict that under certain conditions the intensity ratio of an optically thick to thin line can show an increase over the optically thin value, indicating an enhancement in the former. These conditions include the geometry of the emitting plasma and its orientation to the observer. A similar effect can take place between lines of differing optical depth. Previous observational studies have focused on stellar point sources, and here we investigate the spatially-resolved solar atmosphere using measurements of the I(1032 A)/I(1038 A) intensity ratio of O VI in several regions obtained with the Solar Ultraviolet Measurements of Emitted Radiation (SUMER) instrument on board the Solar and Heliospheric Observatory (SoHO) satellite. We find several I(1032 A)/I(1038 A) ratios observed on the disk to be significantly larger than the optically thin value of 2.0, providing the first detection (to our knowledge) of intensity enhancement in the ratio arising from opacity effects in the solar atmosphere. Agreement between observation and theory is excellent, and confirms that the O VI emission originates from a slab-like geometry in the solar atmosphere, rather than from cylindrical structures.
Using $HST$/COS observations of the twin quasar lines of sight Q$0107-025$A $&$ Q$0107-025$B, we report on the physical properties, chemical abundances and transverse sizes of gas in a multiple galaxy environment at $z = 0.399$ across a transverse se paration of $520$ kpc. The absorber towards Q$0107-025$B has $log N(H I)/cm^{-2} approx 16.8$ (partial Lyman limit) while the absorber towards the other sightline has $N(H I) approx 2$ dex lower. The O VI along both sightlines have comparable column densities and broad $b$-values, whereas the low ionization lines are considerably narrower. The low ionization gas is inconsistent with the O VI when modelled assuming photoionization in a single phase. Along both the lines-of-sight, O VI and coinciding broad H I are best explained through collisional ionization in a cooling plasma with solar metallicity. Ionization models infer $1/10$-th solar metallicity for the pLLS and solar metallicity for the lower column density absorber along the other sightline. Within $pm~250~km~s^{-1}$ and $2$ Mpc of projected distance from the sightlines 12 galaxies are identified, of which 3 are within $300$ kpc. One of them is a dwarf galaxy while the other two are intermediate mass systems at impact parameters of $rho sim (1-4)R_{vir}$. The O VI along both lines-of-sight could be either tracing narrow transition temperature zones at the interface of low ionization gas and the hot halo of nearest galaxy, or a more spread-out warm gas bound to the circumgalactic halo/intragroup medium. This latter scenario leads to a warm gas mass limit of $M gtrsim 4.5 times 10^{9}$ M$_odot$.
101 - Todd M. Tripp 2008
Using high-resolution UV spectra of 16 low-z QSOs, we study the physical conditions and statistics of O VI absorption in the IGM at z < 0.5. We identify 51 intervening (z_{abs} << z_{QSO}) O VI systems comprised of 77 individual components, and we fi nd 14 proximate systems (z_{abs} ~ z_{QSO}) containing 34 components. For intervening systems [components] with rest-frame equivalent width W_{r} > 30 mA, the number of O VI absorbers per unit redshift dN/dz = 15.6(+2.9/-2.4) [21.0(+3.2/-2.8)], and this decreases to dN/dz = 0.9(+1.0/-0.5) [0.3(+0.7/-0.3)] for W_{r} > 300 mA. The number per redshift increases steeply as z_{abs} approaches z_{QSO}, and some proximate absorbers have substantially lower H I/O VI ratios. The lower proximate ratios could be partially due to ionization effects but also require higher metallicities. We find that 37% of the intervening O VI absorbers have velocity centroids that are well-aligned with corresponding H I absorption. If the O VI and the H I trace the same gas, the relatively small differences in line widths imply the absorbers are cool with T < 10^{5} K. Most of these well-aligned absorbers have the characteristics of metal-enriched photoionized gas. However, the O VI in the apparently simple and cold systems could be associated with a hot phase with T ~ 10^{5.5} K if the metallicity is high enough to cause the associated broad Ly alpha absorption to be too weak to detect. We show that 53% of the intervening O VI systems are complex multiphase absorbers that can accommodate both lower metallicity collisionally-ionized gas with T > 10^{5} K and cold photoionzed gas.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا