ترغب بنشر مسار تعليمي؟ اضغط هنا

XMM-Newton EPIC Observation of SMC SNR 0102-72.3

381   0   0.0 ( 0 )
 نشر من قبل Manami Sasaki
 تاريخ النشر 2000
  مجال البحث فيزياء
والبحث باللغة English
 تأليف M. Sasaki




اسأل ChatGPT حول البحث

Results from observations of the young oxygen-rich supernova remnant SNR 0102-72.3 in the Small Magellanic Cloud during the calibration phase of the XMM-Newton Observatory are presented. Both EPIC-PN and MOS observations show a ringlike structure with a radius of ~15 already known from Einstein, ROSAT and Chandra observations. Spectra of the entire SNR as well as parts in the eastern half were analyzed confirming shocked hot plasma in non-uniform ionization stages as the origin of the X-ray emission. The spectra differ in the northeastern and the southeastern part of the X-ray ring, showing emission line features of different strength. The temperature in the northeastern part is significantly higher than in the southeast, reflected by the lines of higher ionization stages and the harder continuum. Comparison to radio data shows the forward shock of the blast wave dominating in the northern part of the SNR, while the southern emission is most likely produced by the recently formed reverse shock in the ejecta. In the case of the overall spectrum of SNR 0102-72.3, the two-temperature non-equilibrium ionization model is more consistent with the data in comparison to the single plane-parallel shock model. The structure of SNR 0102-72.3 is complex due to variations in shock propagation leading to spatially differing X-ray spectra.



قيم البحث

اقرأ أيضاً

We have analyzed the first XMM-Newton, Swift and archival ROSAT PSPC observations of the quasar LBQS 0102-2713.The object was selected from the ROSAT archive as being notable due to the steep soft X-ray photon index and due to the UV brightness based on HST and optical spectroscopic observations. The first XMM-Newton observations carried out in December 2009 and the first Swift observations from 2010 have confirmed the steepness of the soft X-ray photon index, which ranges between 3.35 and 4.41 for the different XMM-Newton and ROSAT detectors, the UV brightness of the source and the absence of significant absorption by neutral hydrogen. The new data allow a combined spectral fitting to the Swift UVOT and the XMM-Newton/ROSAT data which results in a huge luminosity of (6.2+-0.2)x10^47 erg s^(-1) and alpha_ox values ranging between (-1.87+-0.11) and (-2.11+-0.12). The nature of the soft X-ray emission can be explained as local Comptonized emission of the UV disc photons in the pseudo-Newtonian potential. The black hole mass is estimated from the Mg II line and translates into an Eddington ratio of L/L_edd = 18(+33)(-12). For the dimensionless electron temperature of the plasma cloud theta = kT_e/ (m_e c^2) we derive an upper limit of about 10 keV.
70 - G. Ramsay 2002
We present spin-resolved X-ray data of the neutron star binary Her X-1. We find evidence that the Iron line at 6.4 keV originates from the same location as the blackbody X-ray component. The line width and energy varies over both the spin period and the 35 day precession period. We also find that the correlation between the soft and hard X-ray light curves varies over the 35 day period.
67 - J. Nevalainen 2005
We use XMM-Newton blank-sky and closed-cover background data to explore the background subtraction methods for large extended sources filling the EPIC field of view, such as nearby galaxy clusters, for which local background estimation is difficult. We find that to keep the 0.8-7.0 keV band background modeling uncertainty tolerable, one has to use a much more restrictive filter than that commonly applied. In particular, because flares have highly variable spectra, not all of them are identified by filtering the E>10 keV light curve. We tried using the outer part of the EPIC FOV for monitoring the background in a softer band (1-5 keV). We find that one needs to discard the time periods when either the hard-band or the soft-band rate exceeds the nominal value by more than 20% in order to limit the 90% CL background uncertainty to between 5% at E=4-7 keV and 20% at E=0.8-1 keV, for both MOS and PN. This compares to a 10-30% respective PN uncertainty when only the hard-band light curve is used for filtering, and to a 15-45% PN uncertainty when applying the commonly used 2-3 sigma filtering method. We illustrate our method on a nearby cluster A1795. The above background uncertainties convert into the systematic temperature uncertainties between 1% at r=3-4 arcmin and 20--25% (~1 keV for A1795) at r=10-15 arcmin. For comparison, the commonly applied 2-3 sigma clipping of the hard-band light curve misses a significant amount of flares, rendering the temperatures beyond r=10 arcmin unconstrained. Thus, the background uncertainties do not prohibit the EPIC temperature profile analysis of low-brightness regions, like outer regions of galaxy clusters, provided a conservative flare filtering such as the double filtering method with 20% limits is used.
159 - Markus Kuster 2002
The EPIC pn CCD camera on board of XMM-Newton is designed to perform high throughput imaging and spectroscopy as well as high resolution timing observations in the energy range of 0.1-15 keV. A temporal resolution of milliseconds or microseconds, dep ending on the instrument mode and detector, is outstanding for CCD based X-ray cameras. In order to calibrate the different observing modes of the EPIC pn CCD, XMM-Newton observations of the pulsars PSR B1509-58, PSR B0540-69 and the Crab were performed during the calibration and performance verification phase. To determine the accuracy of the on board clock against Coordinated Universal Time (UTC), PSR B1509-58 was observed simultaneously with XMM-Newton and RXTE in addition. The paper summarizes the current status of the clock calibration.
We report the results of preliminary analysis of the XMM_Newton EPIC and RGS observations of the candidate black-hole binary LMC X-3 between February and June 2000. The observations covered both the soft and the hard X-ray spectral states. The hard-s tate spectra were dominated by a power-law component with a photon index Gamma = 1.9 +/- 0.1. The soft-state spectra consisted of a thermal component with a multi-colour disk temperature T_in = 0.9 keV and a power-law tail with Gamma ~ 2.5--2.7. The model in which the X-rays from LMC X-3 in the high-soft state are powered by a strong stellar wind from a massive companion is not supported by the small line-of-sight absorption (n_H <~ 10^{21} cm^{-2}) deduced from the RGS data. The transition from the soft to the hard state appears to be a continuous process associated with the changes in the mass-transfer rate.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا