ﻻ يوجد ملخص باللغة العربية
The energy measurement uncertainty of circular electron positron collider (CEPC) beam must be less than $10 mathrm{MeV}$ to accurately measure the mass of the Higgs/W/Z boson. A new microwave-beam Compton backscattering method is proposed to measure the beam energy by detecting the maximum energy of scattered photons. The uncertainty of the beam energy measurement is $6 mathrm{MeV}$. The detection accuracy of the maximum energy of scattered photons need to reach $10^{-4}$. The high-precision gamma detectors can only be a high-purity germanium (HPGe) detector. It is a semiconductor detector, the effective detection range of the gamma energy is 100$mathrm{keV}$-10$mathrm{MeV}$. The maximum energy of the scattered photons is chosen to be the higher the better to reduce the influence of the synchrotron radiation background. Therefore, the maximum energy of the scattered photons is selected to be 9$mathrm{MeV}$. Therefore, the initial photons should be microwave photons to collide with the electrons with the energy of 120GeV on CEPC. The cylindrical resonant cavity with ${TM_{010}}$ mode is selected to transmit microwaves. After Compton backscattering, the scattered photons emit from the vacuum tube of the synchrotron radiation and the energy is detected by the HPGe detector. The structure of shielding materials with polyethylene and lead is designed to minimize the background noise, such as the synchrotron radiation and the classical radiation from the electron beam in the cavity. The hole radius in the side wall of the cavity is about $1.5mathrm{mm}$ to allow the electron beam to pass through. The computer simulation technology (CST) software shows that the influence of the hole radius on the cavity field is negligible, and the influence of the hole radius on the resonance frequency can be corrected easily.
Double-polarization observables in the reaction $vec{e}p rightarrow evec{p}gamma{}$ have been measured at $Q^2=0.33 (GeV/c)^2$. The experiment was performed at the spectrometer setup of the A1 Collaboration using the 855 MeV polarized electron beam p
A search for neutral heavy leptons (NHLs) has been performed using an instrumented decay channel at the NuTeV (E-815) experiment at Fermilab. The decay channel was composed of helium bags interspersed with drift chambers, and was used in conjunction
The nuclear modification factors R_{AA} and R_{CP} have been used to measure medium-induced suppression in heavy-ion collisions at sqrt{s_{NN}} = 200GeV which was among the earliest evidence for the existence of a strongly interacting medium called a
We demonstrate the splitting of a low-energy electron beam by means of a microwave pseudopotential formed above a planar chip substrate. Beam splitting arises from smoothly transforming the transverse guiding potential for an electron beam from a sin
Based on the high sensitivity of Compton scattering off ultra relativistic electrons, the possibility of anisotropies in the speed of light is investigated. The result discussed in this contribution is based on the gamma-ray beam of the ESRFs GRAAL f