ترغب بنشر مسار تعليمي؟ اضغط هنا

Design and evaluation of a FPGA-ADC prototype for the PET detector based on LYSO Crystals and SiPM arrays

191   0   0.0 ( 0 )
 نشر من قبل Cong Ma
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The aim of this study is to design and evaluate a simple free running Analog-Digital Converter (ADC) based on the Field Programmable Gate Array (FPGA) device to accomplish the energy and position readout of the silicon photomultiplier (SiPM) array for application as PET scanners. This simple FPGA-ADC based on a carry chain Time-Digital Converter (TDC) implemented on a Kintex-7 FPGA consists of only one off-chip resistor so it has greater advantages in improving system integration and reducing cost than commercial chips. In this paper, a FPGA-ADC based front-end electronics prototype is presented, and both the design principle and implementation considerations are discussed. Experiments were performed using an 8 x 8 (crystal size: 4 x 4 x 15 mm3 ) and a 12 x 12 (crystal size: 2.65 x2.65 x 15 mm3 ) segmented LYSO crystals coupled with an 8 x 8 SiPM (Jseries, from ON Semiconductor) array which is under 22Na point source excitation. Initial test results indicate that the energy resolution of the two detectors after correction is around 13.2% and 13.5 % at 511 keV, and the profiles of the flood histograms show a clear visualization of the discrete scintillator element. All measurements were carried out at room temperature (~25 degree), without additional cooling

قيم البحث

اقرأ أيضاً

274 - F. Barbosa , H. Dong , B. Kross 2011
A mini-PET style detector system is being developed for a plant imaging application with a compact array of silicon photomultipliers (SiPM) replacing position sensitive photomultipliers (PSPMT). In addition to compactness, the use of SiPMs will allow imaging setups involving high strength MRI-type magnetic fields. The latter will allow for better position resolution of the initial positron annihilations in the plant tissue. In the present work, prototype arrays are tested for the uniformity of their response as it is known that PSPMTs require significant gain compensation on the individual channels to achieve an improved uniformity in response. The initial tests indicate a high likelihood that the SiPM arrays can be used without any gain compensation.
Position Emission Tomography (PET) is an advanced clinical diagnostic imaging technique for nuclear medicine. Small animal PET is increasingly uesd for studying the animal model of disease, new drugs and new therapies. A prototype of Singles Processi ng Unit (SPU) for a small animal PET system was designed to obtain the time, energy, and position information. The energy and position is actually calculated through high precison charge measurement, which is based on amplification, shaping, A/D conversion and area calculation in digital signal processing domian. Analysis and simulations were also conducted to optimize the key parameters in system design. Initial tests indicate that the charge and time precision is better than 0.3% FWHM and 350 ps FWHM respectively, while the position resolution is better than 0.35% FWHM. Commination tests of the SPU prototype with the PET detector indicate that the system time precision is better than 2.5 ns, while the flood map and energy spectra concored well with the expected.
Small animal Positron Emission Tomography (PET) is dedicated to small animal imaging, which requires high position and energy precision, as well as good flexibility and efficiency of the electronics. This paper presents the design of a digital signal processing logic for a marmoset brain PET system based on LYSO crystal arrays, SiPMs, and the resistive network readout method. We implement 32-channel signal processing in a single Xilinx Artix-7 Field-Programmable Gate Array (FPGA). The logic is designed to support four online modes which are regular data processing mode, flood map construction mode, energy spectrum construction mode, and raw data mode. Several functions are integrated, including two-dimensional (2D) raw position calculation, crystal locating, events filtering, and synchronization detection. Furthermore, a series of online corrections is also integrated, such as photon peak correction to 511 keV and time measurement result correction with crystal granularity. A Gigabit Ethernet interface is utilized for data transfer, Look-Up Tables (LUTs) configuration, and command issuing. The pipeline logic works at 125 MHz with a signal processing capability beyond the required data rate of 1,000,000 events/s/channel. A series of initial tests are conducted. The results indicate that the logic design meets the application requirement.
This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration aims to i ntegrate Time-Of-Flight PET with ultrasound endoscopy in a novel multimodal device, capable to support the development of new biomarkers for prostate and pancreatic tumors. The detector consists in two parts: a PET head mounted on an ultrasound probe and an external PET plate. The challenging goal of 1 mm spatial resolution for the PET image requires a detector with small crystal size, and therefore high channel density: 4096 LYSO crystals individually readout by Silicon Photomultipliers (SiPM) make up the external plate. The quality and properties of these components must be assessed before the assembly. The dark count rate, gain, breakdown voltage and correlated noise of the SiPMs are measured, while the LYSO crystals are evaluated in terms of light yield and energy resolution. In order to effectively reduce the noise in the PET image, high time resolution for the gamma detection is mandatory. The Coincidence Time Resolution (CTR) of all the SiPMs assembled with crystals is measured, and results show a value close to the demanding goal of 200 ps FWHM. The light output is evaluated for every channel for a preliminary detector calibration, showing an average of about 1800 pixels fired on the SiPM for a 511 keV interaction. Finally, the average energy resolution at 511 keV is about 13 %, enough for effective Compton rejection.
The Analogue Hadron Calorimeter (AHCAL) developed by the CALICE collaboration is a scalable engineering prototype for a Linear Collider detector. It is a sampling calorimeter of steel absorber plates and plastic scintillator tiles read out by silicon photomultipliers (SiPMs) as active material (SiPM-on-tile). The front-end chips are integrated into the active layers of the calorimeter and are designed for minimizing power consumption by rapidly cycling the power according to the beam structure of a linear accelerator. 38 layers of the sampling structure are equipped with cassettes containing 576 single channels each, arranged on readout boards and grouped according to the 36 channel readout chips. The prototype has been assembled using techniques suitable for mass production, such as injection-moulding and semi-automatic wrapping of scintillator tiles, assembly of scintillators on electronics using pick-and-place machines and mass testing of detector elements. The calorimeter was commissioned at DESY and was taking data at the CERN SPS at the time of the conference. The contribution discusses the construction, commissioning and first test beam results of the CALICE AHCAL engineering prototype.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا