ترغب بنشر مسار تعليمي؟ اضغط هنا

A highly granular SiPM-on-tile calorimeter prototype

161   0   0.0 ( 0 )
 نشر من قبل Felix Sefkow
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Analogue Hadron Calorimeter (AHCAL) developed by the CALICE collaboration is a scalable engineering prototype for a Linear Collider detector. It is a sampling calorimeter of steel absorber plates and plastic scintillator tiles read out by silicon photomultipliers (SiPMs) as active material (SiPM-on-tile). The front-end chips are integrated into the active layers of the calorimeter and are designed for minimizing power consumption by rapidly cycling the power according to the beam structure of a linear accelerator. 38 layers of the sampling structure are equipped with cassettes containing 576 single channels each, arranged on readout boards and grouped according to the 36 channel readout chips. The prototype has been assembled using techniques suitable for mass production, such as injection-moulding and semi-automatic wrapping of scintillator tiles, assembly of scintillators on electronics using pick-and-place machines and mass testing of detector elements. The calorimeter was commissioned at DESY and was taking data at the CERN SPS at the time of the conference. The contribution discusses the construction, commissioning and first test beam results of the CALICE AHCAL engineering prototype.

قيم البحث

اقرأ أيضاً

725 - M.Danilov 2007
The CALICE collaboration is presently constructing a test hadron calorimeter (HCAL) with 7620 scintillator tiles read out by novel photo-detectors - Silicon Photomultipliers (SiPMs). This prototype is the first device which uses SiPMs on a large scal e. We present the design of the HCAL and report on measured properties of more than 10 thousand SiPMs. We discuss the SiPM efficiency, gain, cross-talk, and noise rate dependence on bias voltage and temperature, including the spread in these parameters. We analyze the reasons for SiPM rejection and present the results of the long term stability studies. The first measurements of the SiPM radiation hardness are presented. We compare properties of SiPM with the properties of similar devices, MRS APD and MPPC. A possibility to make the tiles thinner and to read them out without WLS fibers has been studied.
We explore the fractal nature of particle showers using Monte-Carlo simulation. We define the fractal dimension of showers measured in a high granularity calorimeter designed for a future lepton collider. The shower fractal dimension reveals detailed information of the spatial configuration of the shower. %the information hidden in the details of shower spatial configuration, It is found to be characteristic of the type of interaction and highly sensitive to the nature of the incident particle. Using the shower fractal dimension, we demonstrate a particle identification algorithm that can efficiently separate electromagnetic showers, hadronic showers and non-showering tracks. We also find a logarithmic dependence of the shower fractal dimension on the particle energy.
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV ha ve been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.
The upgrade of the DA$Phi$NE machine layout requires a modification of the size and position of the inner focusing quadrupoles of KLOE-2 thus asking for the realization of two new calorimeters covering the quadrupoles area. To improve the reconstruct ion of $K_Lto 2pi^0$ events with photons hitting the quadrupoles a calorimeter with high efficiency to low energy photons (20-300 MeV), time resolution of less than 1 ns and space resolution of few cm, is needed. To match these requirements, we are designing a tile calorimeter, QCALT, where each single tile is readout by mean of SiPM for a total granularity of 2400 channels. We show first tests of the different calorimeter components.
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, pr oviding sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angular distribution of identified track segments are compared to GEANT4 simulations with several different shower models. Track segments also provide the possibility for in-situ calibration of highly granular calorimeters.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا