ترغب بنشر مسار تعليمي؟ اضغط هنا

Optimal efficiency of high frequency chest wall oscillations and links with resistance and compliance in a model of the lung

89   0   0.0 ( 0 )
 نشر من قبل Benjamin Mauroy
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Chest physiotherapy is a set of techniques, mostly empirical, used to help the draining of the mucus from the lung in pathological situations. The choice of the techniques, and their adjustment to the patients or to the pathologies, remains as of today largely empirical. High Frequency Chest Wall Oscillation (HFCWO) is one of these techniques, performed with a device that applies oscillating pressures on the chest. However, there is no clear understanding of how HFCWO devices interact with the lung biomechanics. Hence, we study idealised HFCWO manipulations applied to a mathematical and numerical model of the biomechanics of the lung. The lung is represented by an airway tree connected to an homogeneous elastic medium. We highlight that the biophysics of the idealised HFCWO is driven by two dimensionless numbers. We show that the stress applied to the mucus plays the role of a buffer for the mucus yield stress, hence reducing the amount of stress needed to mobilize the mucus. The stress is the addition of two stresses with different physical origin and of the same order of magnitude: a stress due to the airway wall deformation and a stress due to the air-mucus interactions. Our model predicts the existence of an optimal range of HFCWO working frequencies that is in agreement with the frequencies actually used during HFCWO oscillations. Moreover, our model suggests that analyzing the mouth airflow during HFCWO could allow to estimate the compliance and the hydrodynamic resistance of the lung of a patient.

قيم البحث

اقرأ أيضاً

A novel radio guided surgery (RGS) technique for cerebral tumors using $beta^{-}$ radiation is being developed. Checking the availability of a radio-tracer that can deliver a $beta^{-}$ emitter to the tumor is a fundamental step in the deployment of such technique. This paper reports a study of the uptake of 90Y labeled (DOTATOC) in the meningioma and the high grade glioma (HGG) and a feasibility study of the RGS technique in these cases.
Over the past few decades, researchers have developed several approaches such as the Reference Phantom Method (RPM) to estimate ultrasound attenuation coefficient (AC) and backscatter coefficient (BSC). AC and BSC can help to discriminate pathology f rom normal tissue during in-vivo imaging. In this paper, we propose a new RPM model to simultaneously compute AC and BSC for harmonic imaging and a normalized score that combines the two parameters as a measure of disease progression. The model utilizes the spectral difference between two regions of interest, the first, a proximal, close to the probe and second, a distal, away from the probe. We have implemented an algorithm based on the model and shown that it provides accurate and stable estimates to within 5% of AC and BSC for simulated received echo from post-focal depths of a homogeneous liver-like medium. For practical applications with time gain and time frequency compensated in-phase and quadrature (IQ) data from ultrasound scanner, the method has been approximated and generalized to estimate AC and BSC for tissue layer underlying a more attenuative subcutaneous layer. The angular spectrum approach for ultrasound propagation in biological tissue is employed as a virtual Reference Phantom (VRP). The VRP is calibrated with a fixed probe and scanning protocol for application to liver tissue. In a feasibility study with 16 subjects, the method is able to separate 9/11 cases of progressive non-alcoholic fatty liver disease from 5 normal. In particular, it is able to separate 4/5 cases of non-alcoholic steato-hepatitis and early fibrosis (F<=2) from normal tissue. More extensive clinical studies are needed to assess the full capability of this model for screening and monitoring disease progression in liver and other tissues.
We develop a framework to uncover and analyze dynamical anomalies from massive, nonlinear and non-stationary time series data. The framework consists of three steps: preprocessing of massive data sets to eliminate erroneous data segments, application of the empirical mode decomposition and Hilbert transform paradigm to obtain the fundamental components embedded in the time series at distinct time scales, and statistical/scaling analysis of the components. As a case study, we apply our framework to detecting and characterizing high frequency oscillations (HFOs) from a big database of rat EEG recordings. We find a striking phenomenon: HFOs exhibit on-off intermittency that can be quantified by algebraic scaling laws. Our framework can be generalized to big data-related problems in other fields such as large-scale sensor data and seismic data analysis.
375 - Linli Shi , Ying Jiang , Yi Zhang 2019
Focused ultrasound has attracted great attention in minimally invasive therapy, gene delivery, brain stimulation, etc. Frequency below 1 MHz has been identified preferable for high-efficacy drug delivery, gene transfection and neurostimulation due to minimized tissue heating and cell fragmentation. However, the poor spatial resolution of several millimeters and the large device diameter of ~25 mm of current sub-MHz ultrasound technology severely hinders its further applications for effective, precise, safe and wearable biomedical studies and clinical use. To address this issue, we report the development of a novel fiber-based optoacoustic emitter (FOE). The FOE, a new miniaturized ultrasound source, is composed of an optical diffusion coating layer and an expansion coating layer at an optical fiber distal end with a diameter of approximately 500 microns. Taking advantage of the fiber size and diffusive nanoparticles introduced, the ultrasound generated by the FOEs showed a spatial confinement of sub-millimeter. The optoacoustic conversion efficiency was maximized through choosing absorbing nanomaterials and thermal expansion matrix. Controllable frequencies in the range of 0.083 MHz to 5.500 MHz were achieved through using the diffusion layer as a damping material or modifying the nano-composition in the expansion layer. This sub-MHz frequency controllability allows FOEs to be used as a localized ultrasound source for precise cell modulation. We demonstrated optoacoustic cell membrane sonoporation with a localization of sub-millimeter and negligible heat deposition, implicating its broad biomedical applications, including region-specific drug delivery, gene transfection as well as localized neuron stimulation.
SPECT systems using pinhole apertures permit radiolabeled molecular distributions to be imaged in vivo in small animals. Nevertheless studying cardiovascular diseases by means of small animal models is very challenging. Specifically, submillimeter sp atial resolution, good energy resolution and high sensitivity are required. We designed what we consider the optimal radionuclide detector system for this task. It should allow studying both detection of unstable atherosclerotic plaques and monitoring the effect of therapies. Using mice is particularly challenging in situations that require several intravenous injections of radiotracers, possibly for week or even months, in chronically ill animals. Thus, alternative routes of delivering the radiotracer in tail vein should be investigated. In this study we have performed preliminary measurements of detection of atherosclerotic plaques in genetically modified mice with high-resolution prototype detector. We have also evaluated the feasibility of assessing left ventricular perfusion by intraperitoneal delivering of MIBI-Tc in healthy mice.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا