ترغب بنشر مسار تعليمي؟ اضغط هنا

Microresonator frequency reference for terahertz precision sensing and metrology

108   0   0.0 ( 0 )
 نشر من قبل Dominik Walter Vogt
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Highly sensitive terahertz (THz) sensors for a myriad of applications are rapidly evolving. A widespread sensor concept is based on the detection of minute resonance frequency shifts due to a targeted specimen in the sensors environment. Therefore, cutting-edge high resolution continuous wave (CW) THz spectrometers provide very powerful tools to investigate the sensors performances. However, unpredictable yet non negligible frequency drifts common to state-of-the-art CW THz spectrometers limit the sensors accuracy for ultra-high precision sensing and metrology. Here, we overcome this deficiency by introducing an ultra-high quality (Q) THz microresonator frequency reference. Measuring the sensors frequency shift relative to a well-defined frequency reference eliminates the unwanted frequency drift, and fully exploits the capabilities of modern CW THz spectrometers as well as THz sensors. In a proof-of-concept experiment, we demonstrate the accurate and repeated detection of minute resonance frequency shifts of less than 5MHz at 0.6THz of a THz microresonator sensor.

قيم البحث

اقرأ أيضاً

A quiet point, an operating point of pump-resonance detuning that minimizes frequency fluctuation due to nonlinear effects inside a resonator, has been employed for phase noise reduction of a soliton Kerr microresonator frequency comb (microcomb). Na turally, it is expected that the use of the point will also improve performances of a microcomb in terms of frequency stability and faithfulness in a phase locked loop. In this study, we experimentally investigate the effect in a microcomb with a repetition frequency of 300~GHz. We obtain a lowest fractional frequency instability at a quiet point of $1.5times 10^{-9}$ at 1 second, which is 44 times lower than free-running instability. Phase-locking of a microcomb to a stabilized fiber comb is demonstrated to evaluate performance in a feedback loop, where in-loop-limited relative fractional frequency instability between the microcomb and the fiber comb of $6.8 times 10^{-13}$ is obtained as an indicator of the stability limitation.
We report on a calibration procedure that enhances the precision of an interferometer based frequency stabilization by several orders of magnitude. For this purpose the frequency deviations of the stabilization are measured precisely by means of a fr equency comb. This allows to implement several calibration steps that compensate different systematic errors. The resulting frequency deviation is shown to be less than $5.7 $MHz (rms $1.6 $MHz) in the whole wavelength interval $750 - 795 $nm. Wide tuning of a stabilized laser at this exceptional precision is demonstrated.
Intense terahertz (THz) electromagnetic fields have been utilized to reveal a variety of extremely nonlinear optical effects in many materials through nonperturbative driving of elementary and collective excitations. However, such nonlinear photoresp onses have not yet been discovered in light-emitting diodes (LEDs), letting alone employing them as fast, cost effective,compact, and room-temperature-operating THz detectors and cameras. Here we report ubiquitously available LEDs exhibited gigantic and fast photovoltaic signals with excellent signal-to-noise ratios when being illuminated by THz field strengths >50 kV/cm. We also successfully demonstrated THz-LED detectors and camera prototypes. These unorthodox THz detectors exhibited high responsivities (>1 kV/W) with response time shorter than those of pyroelectric detectors by four orders of magnitude. The detection mechanism was attributed to THz-field-induced nonlinear impact ionization and Schottky contact. These findings not only help deepen our understanding of strong THz field-matter interactions but also greatly contribute to the applications of strong-field THz diagnosis.
We examine a range of effects arising from ac magnetic fields in high precision metrology. These results are directly relevant to high precision measurements, and accuracy assessments for state-of-the-art optical clocks. Strategies to characterize th ese effects are discussed and a simple technique to accurately determine trap-induced ac magnetic fields in a linear Paul trap is demonstrated using $^{171}mathrm{Yb}^+$
Ultrahigh-resolution optical strain sensors provide powerful tools in various scientific and engineering fields, ranging from long-baseline interferometers to civil and aerospace industries. Here we demonstrate an ultrahigh-resolution fibre strain se nsing method by directly detecting the time-of-flight (TOF) change of the optical pulse train generated from a free-running passively mode-locked laser (MLL) frequency comb. We achieved a local strain resolution of 18 p{epsilon}/Hz1/2 and 1.9 p{epsilon}/Hz1/2 at 1 Hz and 3 kHz, respectively, with largedynamic range of >154 dB at 3 kHz. For remote-point sensing at 1-km distance, 80 p{epsilon}/Hz1/2 (at 1 Hz) and 2.2 p{epsilon}/Hz1/2 (at 3 kHz) resolution is demonstrated. While attaining both ultrahigh resolution and large dynamic range, the demonstrated method can be readily extended for multiple-point sensing as well by taking advantage of the broad optical comb spectra. These advantages may allow various applications of this sensor in geophysical science, structural health monitoring, and underwater science.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا