ترغب بنشر مسار تعليمي؟ اضغط هنا

Calibrating an interferometric laser frequency stabilization to MHz precision

269   0   0.0 ( 0 )
 نشر من قبل Johannes Felix Simon Brachmann
 تاريخ النشر 2012
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We report on a calibration procedure that enhances the precision of an interferometer based frequency stabilization by several orders of magnitude. For this purpose the frequency deviations of the stabilization are measured precisely by means of a frequency comb. This allows to implement several calibration steps that compensate different systematic errors. The resulting frequency deviation is shown to be less than $5.7 $MHz (rms $1.6 $MHz) in the whole wavelength interval $750 - 795 $nm. Wide tuning of a stabilized laser at this exceptional precision is demonstrated.


قيم البحث

اقرأ أيضاً

We present a laser frequency stabilization system that uses a transfer interferometer to stabilize slave lasers to a reference laser. Our implementation uses off-the-shelf optical components along with microcontroller-based digital feedback, and offe rs a simple, flexible and robust way to stabilize multiple laser frequencies to better than 1 MHz.
Demand for low-noise, continuous-wave, frequency-tunable lasers based on semiconductor integrated photonics has been advancing in support of numerous applications. In particular, an important goal is to achieve narrow spectral linewidth, commensurate with bulk-optic or fiber-optic laser platforms. Here, we report on laser-frequency-stabilization experiments with a heterogeneously integrated III/V-Si widely tunable laser and a high-finesse, thermal-noise-limited photonic resonator. This hybrid architecture offers a chip-scale optical-frequency reference with an integrated linewidth of 60 Hz and a fractional frequency stability of 2.5e-13 at 1-second integration time. We explore the potential for stabilization with respect to a resonator with lower thermal noise by characterizing laser-noise contributions such as residual amplitude modulation and photodetection noise. Widely tunable, compact and integrated, cost effective, stable and narrow linewidth lasers are envisioned for use in various fields, including communication, spectroscopy, and metrology.
Laser-frequency stabilization with on-chip photonic integrated circuits will provide compact, low cost solutions to realize spectrally pure laser sources. Developing high-performance and scalable lasers is critical for applications including quantum photonics, precision navigation and timing, spectroscopy, and high-capacity fiber communications. We demonstrate a significant advance in compact, stabilized lasers to achieve a record low integral emission linewidth and precision carrier stabilization by combining integrated waveguide nonlinear Brillouin and ultra-low loss waveguide reference resonators. Using a pair of 56.4 Million quality factor (Q) Si$_3$N$_4$ waveguide ring-resonators, we reduce the free running Brillouin laser linewidth by over an order of magnitude to 330 Hz integral linewidth and stabilize the carrier to 6.5$times$10$^{-13}$ fractional frequency at 8 ms, reaching the cavity-intrinsic thermorefractive noise limit for frequencies down to 80 Hz. This work demonstrates the lowest linewidth and highest carrier stability achieved to date using planar, CMOS compatible photonic integrated resonators, to the best of our knowledge. These results pave the way to transfer stabilized laser technology from the tabletop to the chip-scale. This advance makes possible scaling the number of stabilized lasers and complexity of atomic and molecular experiments as well as reduced sensitivity to environmental disturbances and portable precision atomic, molecular and optical (AMO) solutions.
Highly sensitive terahertz (THz) sensors for a myriad of applications are rapidly evolving. A widespread sensor concept is based on the detection of minute resonance frequency shifts due to a targeted specimen in the sensors environment. Therefore, c utting-edge high resolution continuous wave (CW) THz spectrometers provide very powerful tools to investigate the sensors performances. However, unpredictable yet non negligible frequency drifts common to state-of-the-art CW THz spectrometers limit the sensors accuracy for ultra-high precision sensing and metrology. Here, we overcome this deficiency by introducing an ultra-high quality (Q) THz microresonator frequency reference. Measuring the sensors frequency shift relative to a well-defined frequency reference eliminates the unwanted frequency drift, and fully exploits the capabilities of modern CW THz spectrometers as well as THz sensors. In a proof-of-concept experiment, we demonstrate the accurate and repeated detection of minute resonance frequency shifts of less than 5MHz at 0.6THz of a THz microresonator sensor.
Ultra-low frequency noise lasers have been widely used in laser-based experiments. Most narrow-linewidth lasers are implemented by actively suppressing their frequency noise through a frequency noise servo loop (FNSL). The loop bandwidths (LBW) of FN SLs are currently below megahertz, which is gradually tricky to meet application requirements, especially for wideband quantum sensing experiments. This article has experimentally implemented an FNSL with loop-delay-limited 3.5 MHz LBW, which is an order higher than the usual FNSLs. Using this FNSL, we achieved 70 dB laser frequency noise suppression over 100 kHz Fourier frequency range. This technology has broad applications in vast fields where wideband laser frequency noise suppression is inevitable.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا