ترغب بنشر مسار تعليمي؟ اضغط هنا

Performance of the MICE diagnostic system

262   0   0.0 ( 0 )
 نشر من قبل Paolo Franchini
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams of a neutrino factory and for multi-TeV lepton-antilepton collisions at a muon collider. The international Muon Ionization Cooling Experiment (MICE) has demonstrated the principle of ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. This paper documents the performance of the detectors used in MICE to measure the muon-beam parameters, and the physical properties of the liquid hydrogen energy absorber during running.

قيم البحث

اقرأ أيضاً

Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at a neutrino factory and to provide lepton-antilepton collisions at energies of up to several TeV at a muo n collider. The international Muon Ionization Cooling Experiment (MICE) aims to demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization-cooling channel, the muon beam passes through a material in which it loses energy. The energy lost is then replaced using RF cavities. The combined effect of energy loss and re-acceleration is to reduce the transverse emittance of the beam (transverse cooling). A major revision of the scope of the project was carried out over the summer of 2014. The revised experiment can deliver a demonstration of ionization cooling. The design of the cooling demonstration experiment will be described together with its predicted cooling performance.
Muon accelerators offer an attractive option for a range of future particle physics experiments. They can enable high energy (TeV+) high energy lepton colliders whilst mitigating the difficulty of synchrotron losses, and can provide intense beams of neutrinos for fundamental physics experiments investigating the physics of flavor. The method of production of muon beams results in high beam emittance which must be reduced for efficient acceleration. Conventional emittance control schemes take too long, given the very short (2.2 microsecond) rest lifetime of the muon. Ionisation cooling offers a much faster approach to reducing particle emittance, and the international MICE collaboration aims to demonstrate this technique for the first time. This paper will present the MICE RF system and its role in the context of the overall experiment.
76 - M. Bonesini 2015
The international Muon Ionization Cooling Experiment (MICE) will perform a systematic investigation of ionization cooling of a muon beam. The demonstration is based on a simplified version of a neutrino factory cooling channel. As the emittance measu rement will be done on a particle-by-particle basis, sophisticated beam instrumentation has been developed to measure particle coordinates and timing vs RF. The muon beamline has been characterized and a preliminary measure of the beam emittance, using a particle-by-particle method with only the TOF detector system, has been performed (MICE STEP I). Data taking for the study of the properties that determine the cooling performance (MICE Step IV) has just started in 2015, while the demonstration of ionization cooling with re-acceleration is foreseen for 2017.
The Muon Ionization Cooling Experiment (MICE) has been built at the STFC Rutherford Appleton Laboratory to demonstrate the principle of muon beam phase-space reduction via ionization cooling. Muon beam cooling will be required at a future proton-deri ved neutrino factory or muon collider. Ionization cooling is achieved by passing the beam through an energy-absorbing material, such as liquid hydrogen, and then re-accelerating the beam using RF cavities. This paper describes the hydrogen system constructed for MICE including: the liquid-hydrogen absorber, its associated cryogenic and gas systems, the control and monitoring system, and the necessary safety engineering. The performance of the system in cool-down, liquefaction, and stable operation is also presented.
Wedge absorbers are needed to obtain longitudinal cooling in ionization cooling. They also can be used to obtain emittance exchanges between longitudinal and transverse phase space. There can be large exchanges in emittance, even with single wedges. In the present note we explore the use of wedge absorbers in the MICE experiment to obtain transverse-longitudinal emittance exchanges within present and future operational conditions. The same wedge can be used to explore direct and reverse emittance exchange dynamics, where direct indicates a configuration that reduces momentum spread and reverse is a configuration that increases momentum spread. Analytical estimated and ICOOL and G4BeamLine simulations of the exchanges at MICE parameters are presented. Large exchanges can be obtained in both reverse and direct configurations.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا