ترغب بنشر مسار تعليمي؟ اضغط هنا

Measurement of $^{216}$Po half-life with the CUPID-0 experiment

247   0   0.0 ( 0 )
 نشر من قبل Mattia Beretta
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited exposure. In this paper, we present a further application. Exploiting the analysis of delayed coincidence, we can identify the signals caused by the $^{220}$Rn-$^{216}$Po decay sequence on an event-by-event basis. The analysis of these events allows us to extract the time differences between the two decays, leading to a new evaluation of $^{216}$ half-life, estimated as (143.3 $pm$ 2.8) ms.

قيم البحث

اقرأ أيضاً

CUPID-0 is the first large mass array of enriched Zn$^{82}$Se scintillating low temperature calorimeters, operated at LNGS since 2017. During its first scientific runs, CUPID-0 collected an exposure of 9.95 kg yr. Thanks to the excellent rejection of $alpha$ particles, we attained the lowest background ever measured with thermal detectors in the energy region where we search for the signature of $^{82}$Se neutrinoless double beta decay. In this work we develop a model to reconstruct the CUPID-0 background over the whole energy range of experimental data. We identify the background sources exploiting their distinctive signatures and we assess their extremely low contribution (down to $sim10^{-4}$ counts/(keV kg yr)) in the region of interest for $^{82}$Se neutrinoless double beta decay search. This result represents a crucial step towards the comprehension of the background in experiments based on scintillating calorimeters and in next generation projects such as CUPID.
The half-life of $^{212}$Po was measured with the highest up-to-date accuracy as $T_{1/2}=295.1(4)$ ns by using thorium-loaded liquid scintillator.
The half-life of $^{19}$Ne has been measured using a real-time digital multiparametric acquisition system providing an accurate time-stamp and relevant information on the detectors signals for each decay event. An exhaustive offline analysis of the d ata gave unique access to experimental effects potentially biasing the measurement. After establishing the influence factors impacting the measurement such as after-pulses, pile-up, gain and base line fluctuations, their effects were accurately estimated and the event selection optimized. The resulting half-life, $17.2569pm0.0019_{(stat)}pm0.0009_{(syst)}$~s, is the most precise up to now for $^{19}$Ne. It is found in agreement with two recent precise measurements and not consistent with the most recent one [L.J. Broussard {it et al.}, Phys. Rev. Lett. {bf112}, 212301 (2014)] by 3.0 standard deviations. The full potential of the technique for nuclei with half-lives of a few seconds is discussed.
Results of a comparative analysis of the $^{214}$Po ($T_{1/2}= 163.47pm0.03$ $mu$s), $^{213}$Po ($T_{1/2}=3.705 pm 0.001$ $mu$s) and $^{212}$Po ($T_{1/2}=294.09pm0.07$ ns) half-life annular variation parameters are presented. It is shown that two ind ependent sequential sets of the $^{214}$Po $tau$-values $(tauequiv T_{1/2})$ obtained in the spaced laboratories can be described by sinusoidal functions. The sinusoid curve with amplitude $A=(5.0 pm1.5) cdot 10^{-4}$, period $omega=(365pm 8)$ days, and phase $phi=(170 pm 7)$ days approximates the set of $^{214}$Po $tau$ values obtained at BNO INR RAS during the $sim$973 days starting on January 4, 2012. The function approximates a set of $tau$-values with a time duration of $sim1460$ days obtained at the KhNU has an amplitude $A=(4.9pm1.8)cdot10^{-4}$, a period $omega= (377pm13)$ days and a phase $phi=(77pm10)$ days. The $^{213}$Po $tau$-value set with a time duration of $sim1700$ days can be described by a sinusoidal function with an amplitude $A=(3.9pm1.2)cdot10^{-4}$, a period $omega= (370pm13)$ days and a phase $phi=(130pm9)$ days. The $^{212}$Po $tau$-value set with a time duration of $sim670$ days can be described by a sinusoidal function with an amplitude $A=(7.5pm1.6)cdot10^{-4}$, a period $omega= (375pm13)$ days and a phase $phi=(40pm10)$ days.
We report the result of the search for neutrinoless double beta decay of $^{82}$Se obtained with CUPID-0, the first large array of scintillating Zn$^{82}$Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 k g yr $^{82}$Se exposure and we set the most stringent lower limit on the onu $^{82}$Se half-life T$^{0 u}_{1/2}>$ 2.4$times mathrm{10}^{24}$ yr (90% credible interval), which corresponds to an effective Majorana neutrino mass m$_{betabeta} <$ (376-770) meV depending on the nuclear matrix element calculations. The heat-light readout provides a powerful tool for the rejection of al particles and allows to suppress the background in the region of interest down to (3.6$^{+1.9}_{-1.4}$)$times$10$^{-3}$ckky, an unprecedented level for this technique.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا