ترغب بنشر مسار تعليمي؟ اضغط هنا

High Precision Measurement of the $^{19}$Ne Half-life using real-time digital acquisition

305   0   0.0 ( 0 )
 نشر من قبل Xavier Fl\\'echard
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The half-life of $^{19}$Ne has been measured using a real-time digital multiparametric acquisition system providing an accurate time-stamp and relevant information on the detectors signals for each decay event. An exhaustive offline analysis of the data gave unique access to experimental effects potentially biasing the measurement. After establishing the influence factors impacting the measurement such as after-pulses, pile-up, gain and base line fluctuations, their effects were accurately estimated and the event selection optimized. The resulting half-life, $17.2569pm0.0019_{(stat)}pm0.0009_{(syst)}$~s, is the most precise up to now for $^{19}$Ne. It is found in agreement with two recent precise measurements and not consistent with the most recent one [L.J. Broussard {it et al.}, Phys. Rev. Lett. {bf112}, 212301 (2014)] by 3.0 standard deviations. The full potential of the technique for nuclei with half-lives of a few seconds is discussed.

قيم البحث

اقرأ أيضاً

273 - B. Blank , G. Savard , J. Doring 2003
The beta-decay half-life of 62Ga has been studied with high precision using on-line mass separated samples. The decay of 62Ga which is dominated by a 0+ to 0+ transition to the ground state of 62Zn yields a half-life of T_{1/2} = 116.19(4) ms. This r esult is more precise than any previous measurement by about a factor of four or more. The present value is in agreement with older literature values, but slightly disagrees with a recent measurement. We determine an error weighted average value of all experimental half-lives of 116.18(4) ms.
Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experime nts. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited exposure. In this paper, we present a further application. Exploiting the analysis of delayed coincidence, we can identify the signals caused by the $^{220}$Rn-$^{216}$Po decay sequence on an event-by-event basis. The analysis of these events allows us to extract the time differences between the two decays, leading to a new evaluation of $^{216}$ half-life, estimated as (143.3 $pm$ 2.8) ms.
A high-precision half-life measurement for the superallowed Fermi $beta^+$ emitter $^{22}$Mg was performed at the TRIUMF-ISAC facility using a 4$pi$ proportional gas counter. The result of $T_{1/2} = 3.87400 pm 0.00079$ s is a factor of 3 more precis e than the previously adopted world average and resolves a discrepancy between the two previously published $^{22}$Mg half-life measurements.
We report a precise determination of the 19Ne half-life to be $T_{1/2} = 17.262 pm 0.007$ s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current Standard Model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measurements. Our findings prompt a reassessment of results from previous high-precision lifetime measurements that used similar equipment and methods.
The half-life of tsups{37}K has been measured to be $1.23651(94)~mathrm{s}$, a value nearly an order of magnitude more precise than the best previously reported. The $beta^+$ decay of tsups{37}K occurs mainly via a superallowed branch to the ground-s tate of its $T=1/2$ mirror, tsups{37}Ar. This transition has been used recently, together with similar transitions from four other nuclei, as an alternative test of CVC and method for determining $V_{ud}$, but the precision of its $ft$ value was limited by the relatively large half-life uncertainty. Our result corrects that situation. Another motivation for improving the $ft$ value was to determine the standard-model prediction for the $beta$-decay correlation parameters, which will be compared to those currently being measured by the trinat{} collaboration at triumf. The new $ft$ value, $4605(8)~mathrm{s}$, is now limited in precision by the $97.99(14)%$ ground-state branching ratio.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا