ترغب بنشر مسار تعليمي؟ اضغط هنا

Enhancement of the X-Arapuca photon detection device for the DUNE experiment

360   0   0.0 ( 0 )
 نشر من قبل Carla Maria Cattadori
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

In the Deep Underground Neutrino Experiment (DUNE), the VUV LAr luminescence is collected by light trap devices named X-Arapuca, sizing (480x93) mm2. Six thousand of these units will be deployed in the first DUNE ten kiloton far detector module. In this work we present the first characterization of the photon detection efficiency of an X-Arapuca device sizing (200x75) mm2 via a complete and accurate set of measurements along the cell longitudinal axis with a movable 241-Am source. The MPPCs photosensors are readout by a cryogenic transimpedance amplifier to enhance the single photoelectron sensitivity and improve the signal-to-noise while ganging 8 MPPC for a total surface of 288 mm2. Moreover we developed a new photon downshifting polymeric material, by which the X-Arapuca photon detection efficiency was enhanced of about +50% with respect to the baseline off-shell product deployed in the standard device configuration. The achieved results are compared to previous measurements on a half size X-Arapuca device, with a fixed source facing the center, with no cold amplification stage, and discussed in view of the DUNE full size optical cell construction for both the horizontal and the vertical drift configurations of the DUNE TPC design and in view of liquid Argon doping by ppms of Xe. Other particle physics projects adopting Liquid Argon as target or active veto, as Dark Side and LEGEND or the DUNE Near Detector will take advantage of this novel wavelength shifting material.



قيم البحث

اقرأ أيضاً

The ARAPUCA is a novel concept for liquid argon scintillation light detection which has been proposed for the photon detection system of the Deep Underground Neutrino Experiment. The test in liquid argon of one of the first ARAPUCA prototypes is pres ented in this work, where the working principle is experimentally demonstrated. The prototype has an acceptance window of 9 cm$^2$ and is read-out by a single SiPM with active area of 0.36 cm$^2$. Its global detection efficiency was estimated by exposing it to a $^{238}U$ $alpha$ source and to cosmic rays and was found to be 1.15% $pm$ 0.15%, in good agreement with the prediction of a detailed Monte Carlo simulation of the device. Several other ARAPUCA prototypes of bigger dimensions and read-out by arrays of SiPMs have been built and are actually under test. In particular 32 ARAPUCA cells have been installed inside the protoDUNE detector, which is being assembled at CERN and will be operated in the second half of 2018.
In this paper we report on the characterization of SiPM tiles developed for the R & D on the DUNE Photon Detection System. The tiles were produced by Fondazione Bruno Kessler (FBK) employing NUV-HD-SF SiPMs. Special emphasis is given on cryo-reliabil ity of the sensors, i.e. the stability of electric and mechanical properties after thermal cycles at room and 77K temperature. The characterization includes the determination of the I-V curve, a high sensitivity measurement of Dark Count Rate at different overvoltages, and correlated noise. The single p.e. sensitivity is measured as a function of the number of sensors connected to a single electronic channel, after amplification at 77K using a dedicated cold amplifier.
The Liquid Argon Time Projection Chambers (LArTPCs) are a choice for the next generation of large neutrino detectors due to their optimal performance in particle tracking and calorimetry. The detection of Argon scintillation light plays a crucial rol e in the event reconstruction as well as the time reference for non-beam physics such as supernovae neutrino detection and baryon number violation studies. In this contribution, we present the current R&D work on the ARAPUCA (Argon R&D Advanced Program at UNICAMP), a light trap device to enhance Ar scintillation light collection and thus the overall performance of LArTPCs. The ARAPUCA working principle is based on a suitable combination of dichroic filters and wavelength shifters to achieve a high efficiency in light collection. We discuss the operational principles, the last results of laboratory tests and the application of the ARAPUCA as the alternative photon detection system in the protoDUNE detector.
219 - T. Alion , J.J. Back , A. Bashyal 2016
The LBNF/DUNE CDR describes the proposed physics program and experimental design at the conceptual design phase. Volume 2, entitled The Physics Program for DUNE at LBNF, outlines the scientific objectives and describes the physics studies that the DU NE collaboration will perform to address these objectives. The long-baseline physics sensitivity calculations presented in the DUNE CDR rely upon simulation of the neutrino beam line, simulation of neutrino interactions in the far detector, and a parameterized analysis of detector performance and systematic uncertainty. The purpose of this posting is to provide the results of these simulations to the community to facilitate phenomenological studies of long-baseline oscillation at LBNF/DUNE. Additionally, this posting includes GDML of the DUNE single-phase far detector for use in simulations. DUNE welcomes those interested in performing this work as members of the collaboration, but also recognizes the benefit of making these configurations readily available to the wider community.
The X-ARAPUCA device is the baseline choice for the photon detection system of the first far detector module of the DUNE experiment. We present the results of the first complete characterization of a small scale X-ARAPUCA prototype, which is a slice of a full DUNE module. Its total detection efficiency in liquid argon was measured with three different ionizing radiations: $alpha$ particles, $gamma$s and muons and resulted to be $sim$3.0%. This value comfortably satisfies the requirements of the first DUNE far detector module (detection efficiency $>$2.0%) and allows to achieve an energy resolution comparable to the one achievable with the Time Projection Chambers for energies below 10 MeV, which is the region relevant for Supernova neutrino detection.