ترغب بنشر مسار تعليمي؟ اضغط هنا

Large-Area SiPM Pixels (LASiPs): a cost-effective solution towards compact large SPECT cameras

85   0   0.0 ( 0 )
 نشر من قبل Daniel Guberman
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Single Photon Emission Computed Tomography (SPECT) scanners based on photomultiplier tubes (PMTs) are still largely employed in the clinical environment. A standard camera for full-body SPECT employs $sim50$-100 PMTs of 4-8~cm diameter and is shielded by a thick layer of lead, becoming a heavy and bulky system that can weight a few hundred kilograms. The volume, weight and cost of a camera can be significantly reduced if the PMTs are replaced by silicon photomultipliers (SiPMs). The main obstacle to use SiPMs in full-body SPECT is the limited size of their sensitive area. A few thousand channels would be needed to fill a camera if using the largest commercially-available SiPMs of 6$times$6~mm$^2$. As a solution, we propose to use Large-Area SiPM Pixels (LASiPs), built by summing individual currents of several SiPMs into a single output. We developed a LASiP prototype that has a sensitive area 8 times larger than a 6$times$6~mm$^2$ SiPM. We built a proof-of-concept micro-camera consisting of a 40$times$40$times$8~mm$^3$ NaI(Tl) crystal coupled to 4 LASiPs. We evaluated its performance in a central region of $15times15$~mm$^2$, where we were able to reconstruct images of a $^{99m}$Tc capillary with an intrinsic spatial resolution of $sim2$~mm and an energy resolution of $sim11.6$% at 140 keV. We used these measurements to validate Geant4 simulations of the system. This can be extended to simulate a larger camera with more and larger pixels, which could be used to optimize the implementation of LASiPs in large SPECT cameras. We provide some guidelines towards this implementation.

قيم البحث

اقرأ أيضاً

Superconducting nanowire single photon detectors (SNSPDs) are typically used as single-mode-fiber-coupled single-pixel detectors, but large area detectors are increasingly critical for applications ranging from microscopy to free-space quantum commun ications. Here, we explore changes in the rising edge of the readout pulse for large-area SNSPDs as a function of the bias current, optical spot size on the detector, and number of photons per pulse. We observe a bimodal distribution of rise times and show that the probability of a slow rise time increases in the limit of large spot sizes and small photon number. In the limit of low bias currents, the dark-count readout pulse is most similar to the combined large spot size and small-photon-number bright-count readout pulse. These results are consistent with a simple model of traveling microwave modes excited by single photons incident at varying positions along the length of the nanowire.
104 - Giacomo Mauri 2019
Neutron scattering techniques offer a unique combination of structural and the dynamic information of atomic and molecular systems over a wide range of distances and times. The increasing complexity in science investigations driven by technological a dvances is reflected in the studies of neutron scattering science, which enforces a diversification and an improvement of experimental tools, from the instrument design to the detector performance. It calls as well for more advanced data analysis and modelling. The improvements in resolution, count rate and signal-to-background ratio, achievable with the new instrumentations, also drive the research of alternative technologies to replace the 3He-based detector technology unable to fulfil the requirement of increasing performance. Two solution have been studied: a boron-10-based gaseous detector, the Multi-Blade and a solid-state Si-Gd detector. Both solution are suitable alternatives for neutron detection, able to meet the demands of high performance. It has been shown not only the technical characteristic of the devices, but how the science can profit from the better performance of these new detector technologies in real experimental condition.
This work illustrates and compares some methods to measure the most relevant parameters of silicon photo-multipliers (sipm{}s), such as photon detection efficiency as a function of over-voltage and wavelength, dark count rate, optical cross-talk, aft erpulse probability. For the measurement of the breakdown voltage, $V_{BD}$, several methods using the current-voltage $IV$ curve are compared, such as the IV Model, the relative logarithmic derivative, the inverse logarithmic derivative, the second logarithmic derivative, and the third derivative models. We also show how some of these characteristics can be quite well described by few parameters and allow, for example, to build a function of the wavelength and over-voltage describing the photodetection efficiency. This is fundamental to determine the working point of SiPMs in applications where external factors can affect it. These methods are applied to the large area monolithic hexagonal SiPM S10943-2832(X), developed in collaboration with Hamamatsu and adopted for a camera for a gamma-ray telescope, called the SST-1M. We describe the measurements of the performance at room temperature of this device. The methods used here can be applied to any other device and the physics background discussed here are quite general and valid for a large phase-space of the parameters.
Large-area PhotoMultiplier Tubes (PMT) allow to efficiently instrument Liquid Scintillator (LS) neutrino detectors, where large target masses are pivotal to compensate for neutrinos extremely elusive nature. Depending on the detector light yield, sev eral scintillation photons stemming from the same neutrino interaction are likely to hit a single PMT in a few tens/hundreds of nanoseconds, resulting in several photoelectrons (PEs) to pile-up at the PMT anode. In such scenario, the signal generated by each PE is entangled to the others, and an accurate PMT charge reconstruction becomes challenging. This manuscript describes an experimental method able to address the PMT charge reconstruction in the case of large PE pile-up, providing an unbiased charge estimator at the permille level up to 15 detected PEs. The method is based on a signal filtering technique (Wiener filter) which suppresses the noise due to both PMT and readout electronics, and on a Fourier-based deconvolution able to minimize the influence of signal distortions ---such as an overshoot. The analysis of simulated PMT waveforms shows that the slope of a linear regression modeling the relation between reconstructed and true charge values improves from $0.769 pm 0.001$ (without deconvolution) to $0.989 pm 0.001$ (with deconvolution), where unitary slope implies perfect reconstruction. A C++ implementation of the charge reconstruction algorithm is available online at http://www.fe.infn.it/CRA .
427 - W.B.Atwood , S.Ritz , P.Anthony 1999
A beam test of GLAST (Gamma-ray Large Area Space Telescope) components was performed at the Stanford Linear Accelerator Center in October, 1997. These beam test components were simp
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا