ترغب بنشر مسار تعليمي؟ اضغط هنا

Test Beam Study of SiPM-on-Tile Configurations

79   0   0.0 ( 0 )
 نشر من قبل Michael Krohn
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Light yield and spatial uniformity for a large variety of configurations of scintillator tiles was studied. The light from each scintillator was collected by a Silicon Photomultiplier (SiPM) directly viewing the produced scintillation light (SiPM-on-tile technique). The varied parameters included tile transverse size, tile thickness, tile wrapping material, scintillator composition, and SiPM model. These studies were performed using 120 GeV protons at the Fermilab Test Beam Facility. External tracking allowed the position of each proton penetrating a tile to be measured. The results were compared to a GEANT4 simulation of each configuration of scinitillator, wrapping, and SiPM.

قيم البحث

اقرأ أيضاً

The Analogue Hadron Calorimeter (AHCAL) developed by the CALICE collaboration is a scalable engineering prototype for a Linear Collider detector. It is a sampling calorimeter of steel absorber plates and plastic scintillator tiles read out by silicon photomultipliers (SiPMs) as active material (SiPM-on-tile). The front-end chips are integrated into the active layers of the calorimeter and are designed for minimizing power consumption by rapidly cycling the power according to the beam structure of a linear accelerator. 38 layers of the sampling structure are equipped with cassettes containing 576 single channels each, arranged on readout boards and grouped according to the 36 channel readout chips. The prototype has been assembled using techniques suitable for mass production, such as injection-moulding and semi-automatic wrapping of scintillator tiles, assembly of scintillators on electronics using pick-and-place machines and mass testing of detector elements. The calorimeter was commissioned at DESY and was taking data at the CERN SPS at the time of the conference. The contribution discusses the construction, commissioning and first test beam results of the CALICE AHCAL engineering prototype.
728 - M.Danilov 2007
The CALICE collaboration is presently constructing a test hadron calorimeter (HCAL) with 7620 scintillator tiles read out by novel photo-detectors - Silicon Photomultipliers (SiPMs). This prototype is the first device which uses SiPMs on a large scal e. We present the design of the HCAL and report on measured properties of more than 10 thousand SiPMs. We discuss the SiPM efficiency, gain, cross-talk, and noise rate dependence on bias voltage and temperature, including the spread in these parameters. We analyze the reasons for SiPM rejection and present the results of the long term stability studies. The first measurements of the SiPM radiation hardness are presented. We compare properties of SiPM with the properties of similar devices, MRS APD and MPPC. A possibility to make the tiles thinner and to read them out without WLS fibers has been studied.
In recent years, SiPM photoelectric devices have drawn much attention in the domain of time-of-flight-based positron emission tomography (TOF-PET). Using them to construct PET detectors with excellent coincidence time resolution (CTR) is always one o f research focus. In this paper, a SiPM readout pre-amplifier based on common-base current amplifier structure followed by a Pole-Zero (PZ) compensation network is constructed, and the main factors that affect the timing performance of the PET detector are investigated. By experimental measurement, we found that the CTR is heavily related to the bandwidth of the amplifier, bias voltage of SiPM, comparator threshold, and PZ network parameter. The test setup has two detectors, one with LYSO crystal (3 mm 3 mm 10 mm) coupled with a Hamamatsu SiPM (S12642-0404), and the other with LaBr3 coupled to a PMT-R9800. After the optimization of the readout circuit with related factors, the CTR between the two detectors is measured as 266ps FWHM. The test result is a helpful guideline for the readout ASIC chip design in our next step.
855 - D.L. Zhang , M. Gao , X.L. Sun 2021
The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) satellite consists of two small satellites. Each GECAM payload contains 25 gamma ray detectors (GRD) and 8 charged particle detectors (CPD). GRD is the main detect or which can detect gamma-rays and particles and localize the Gamma-Ray Bursts (GRB),while CPD is used to help GRD to discriminate gamma-ray bursts and charged particle bursts. The GRD makes use of lanthanum bromide (LaBr3) crystal readout by SiPM. As the all available SiPM devices belong to commercial grade, quality assurance tests need to be performed in accordance with the aerospace specifications. In this paper, we present the results of quality assurance tests, especially a detailed mechanism analysis of failed devices during the development of GECAM. This paper also summarizes the application experience of commercial-grade SiPM devices in aerospace payloads, and provides suggestions for forthcoming SiPM space applications.
121 - Satoru Uozumi 2010
In Japan, China and Russia, there are several test beam lines available or will become available in near future. Those are open for users who need electron, muon and charged pion beams with energies of 1-50 GeV for any tests of small-size detectors. In this manuscript I present a current status of those test beam facilities in the Asian region.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا