ترغب بنشر مسار تعليمي؟ اضغط هنا

Practical Utility PV Multilevel Inverter Solutions

56   0   0.0 ( 0 )
 نشر من قبل John Buczek
 تاريخ النشر 2021
والبحث باللغة English




اسأل ChatGPT حول البحث

Multilevel inverters are used to improve powerquality and reduce component stresses. This paper describesand compares two multilevel cascaded three phase inverterimplementations with two different modulation techniques: PhaseShifted Pulse Width Modulation, and Nearest Level Control.Further analysis will show required number of inverter levelswith respect to modulation techniques to provide desired powerand power quality to resistive load or grid. Cascaded inverterwill be designed and simulated to draw power from PV cells.

قيم البحث

اقرأ أيضاً

This paper presents a trajectory tracking control strategy that modulates the active power injected by geographically distributed inverter-based resources to support transient stability. Each resource is independently controlled, and its response dri ves the local bus voltage angle toward a trajectory that tracks the angle of the center of inertia. The center-of-inertia angle is estimated in real time from wide-area measurements. The main objectives are to stabilize transient disturbances and increase the amount of power that can be safely transferred over key transmission paths without loss of synchronism. Here we envision the actuators as utility-scale energy storage systems; however, equivalent examples could be developed for partially-curtailed photovoltaic generation and/or Type 4 wind turbine generators. The strategy stems from a time-varying linearization of the equations of motion for a synchronous machine. The control action produces synchronizing torque in a special reference frame that accounts for the motion of the center of inertia. This drives the system states toward the desired trajectory and promotes rotor angle stability. For testing we employ a reduced-order dynamic model of the North American Western Interconnection. The results show that this approach improves system reliability and can increase capacity utilization on stability-limited transmission corridors.
Power system restoration is an important part of system planning. Power utilities are required to maintain black start capable generators that can energize the transmission system and provide cranking power to non-blackstart capable generators. Tradi tionally, hydro and diesel units are used as black start capable generators. With the increased penetration of bulk size solar farms, inverter based generation can play an important role in faster and parallel black start thus ensuring system can be brought back into service without the conventional delays that can be expected with limited black start generators. Inverter-based photovoltaic (PV) power plants have advantages that are suitable for black start. This paper proposes the modeling, control, and simulation of a grid-forming inverter-based PV-battery power plant that can be used as a black start unit. The inverter control includes both primary and secondary control loops to imitate the control of a conventional synchronous machine. The proposed approach is verified using a test system modified from the IEEE 9-bus system in the time-domain electromagnetic transient simulation tool PSCAD. The simulation results shows voltage and frequency stability during a multi-step black-start and network energization process.
Faults in photovoltaic (PV) systems can seriously affect the efficiency, energy yield as well as the security of the entire PV plant, if not detected and corrected quickly. Therefore, fault diagnosis of PV arrays is indispensable for improving the re liability, efficiency, productivity and safety of PV power stations. Instead of conventional thresholding methods and artificial intelligent (AI) machine learning approaches, an innovative Gaussian Mixture Model (GMM) based fault detection approach is proposed in this work. This approach combines the superiority of GMM in modeling stochastic power outputs of PV modules and the flexibility and simplicity of Sandia PV Array Performance Model (SPAM) to accurately detect under-performing modules. Firstly, GMM is proposed to represent the probabilistic distribution functions (PDF) of different PV modules power outputs, and the parameter sets of which are obtained by Expectation Maximization algorithm. Secondly, a simplified explicit expression for output power of PV modules, which highlights the influences of tilt and azimuth angles, is deduced based on the SPAM. Then, an orientation independent vector C is developed to eliminate the probability distribution differences of power outputs caused by varying azimuth angles and tilt angles. Jensen-Shannon (JS) divergence, which captures the differences between probability density of C of each PV module, are generated and used as fault indicators. Simulation data acquired from the original SPAM are used to assess the performance of the proposed approach. Results show that the proposed approach successfully detects faults in PV systems. This work is especially suitable for the PV modules that have different installation parameters such as azimuth angles and tilt angles, and it does not require the use of irradiance or temperature sensors.
The distributed cooperative controllers for inverter-based systems rely on communication networks that make them vulnerable to cyber anomalies. In addition, the distortion effects of such anomalies may also propagate throughout inverter-based cyber-p hysical systems due to the cooperative cyber layer. In this paper, an intelligent anomaly mitigation technique for such systems is presented utilizing data driven artificial intelligence tools that employ artificial neural networks. The proposed technique is implemented in secondary voltage control of distributed cooperative control-based microgrid, and results are validated by comparison with existing distributed secondary control and real-time simulations on real-time simulator OPAL-RT.
73 - Peter Lusis 2020
Autonomous droop control PV inverters have improved voltage regulation compared to the inverters without grid support functions, but more flexible control techniques will be required as the number of solar photovoltaic (PV) installations increases. T his paper studies three inverter future deployment scenarios with droop control inverters, non-exporting inverters, and coordinated inverter control (CIC). The network operation and the interaction between various inverter control methods are studied by simulating inverter operation on two low-voltage networks. Considering 30% PV penetration as the base case, we demonstrate that coordinated inverters can mitigate overvoltages and voltage fluctuations caused by the tripping of passive inverters in 85% of PV location cases when at least as many coordinated as passive inverters are deployed on the 114-node test feeder. However, this rate reduced to 37% with the IEEE 906-node network demonstrating that the deployment of coordinated inverter control may not be able to reverse passive inverter-related voltage disturbances when the build-up of passive inverters has reached a certain threshold. The aggregated PV output from coordinated inverters can be also used to provide grid support services. When the low-voltage networks operate close to the upper voltage limits, the change in the power output from coordinated inverters following a regulation request may be partially offset by passive inverters. Considering an equal number of passive and coordinated inverters, this paper shows that for each unit of the down-regulation request delivered by coordinated inverters, passive inverter output may increase by up to 0.2 units and decrease by up to 0.45 units during coordinated inverter up-regulation.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا