The design and implementation of astronomical cameras based on the large-format CCD and CMOS detectors is described in this paper. The Dinacon-5 controller is used for work with the CCDs and to achieve high performance and low noise. A new controller is designed for CMOS sensors. The main characteristics of the provided systems are estimated on the basis of experimental data. The spatial autocorrelation analysis is applied for PSF estimation. The obtained test results are presented.

قيم البحث

اقرأ أيضاً

Silicon photomultipliers (SiPMs) have become the baseline choice for cameras of the small-sized telescopes (SSTs) of the Cherenkov Telescope Array (CTA). On the other hand, SiPMs are relatively new to the field and covering large surfaces and operati ng at high data rates still are challenges to outperform photomultipliers (PMTs). The higher sensitivity in the near infra-red and longer signals compared to PMTs result in higher night sky background rate for SiPMs. However, the robustness of the SiPMs represents a unique opportunity to ensure long-term operation with low maintenance and better duty cycle than PMTs. The proposed camera for large size telescopes will feature $0.05 degree pixels, low power and fast front-end electronics and a fully digital readout. In this work, we present the status of dedicated simulations and data analysis for the performance estimation. The design features and the different strategies identified, so far, to tackle the demanding requirements and the improved performance are described.
96 - K. Kohno , R. Kawabe , Y. Tamura 2021
We present a conceptual study of a large format imaging spectrograph for the Large Submillimeter Telescope (LST) and the Atacama Large Aperture Submillimeter Telescope (AtLAST). Recent observations of high-redshift galaxies indicate the onset of earl iest star formation just a few 100 million years after the Big Bang (i.e., z = 12--15), and LST/AtLAST will provide a unique pathway to uncover spectroscopically-identified first forming galaxies in the pre-reionization era, once it will be equipped with a large format imaging spectrograph. We propose a 3-band (200, 255, and 350 GHz), medium resolution (R = 2,000) imaging spectrograph with 1.5 M detectors in total based on the KATANA concept (Karatsu et al. 2019), which exploits technologies of the integrated superconducting spectrometer (ISS) and a large-format imaging array. A 1-deg2 drilling survey (3,500 hr) will capture a large number of [O III] 88 um (and [C II] 158 um) emitters at z = 8--9, and constrain [O III] luminosity functions at z > 12.
Millimeter-wave continuum astronomy is today an indispensable tool for both general Astrophysics studies and Cosmology. General purpose, large field-of-view instruments are needed to map the sky at intermediate angular scales not accessible by the hi gh-resolution interferometers and by the coarse angular resolution space-borne or ground-based surveys. These instruments have to be installed at the focal plane of the largest single-dish telescopes. In this context, we have constructed and deployed a multi-thousands pixels dual-band (150 and 260 GHz, respectively 2mm and 1.15mm wavelengths) camera to image an instantaneous field-of-view of 6.5arc-min and configurable to map the linear polarization at 260GHz. We are providing a detailed description of this instrument, named NIKA2 (New IRAM KID Arrays 2), in particular focusing on the cryogenics, the optics, the focal plane arrays based on Kinetic Inductance Detectors (KID) and the readout electronics. We are presenting the performance measured on the sky during the commissioning runs that took place between October 2015 and April 2017 at the 30-meter IRAM (Institut of Millimetric Radio Astronomy) telescope at Pico Veleta. NIKA2 has been successfully deployed and commissioned, performing in-line with the ambitious expectations. In particular, NIKA2 exhibits FWHM angular resolutions of around 11 and 17.5 arc-seconds at respectively 260 and 150GHz. The NEFD (Noise Equivalent Flux Densities) demonstrated on the maps are, at these two respective frequencies, 33 and 8 mJy*sqrt(s). A first successful science verification run has been achieved in April 2017. The instrument is currently offered to the astronomical community during the coming winter and will remain available for at least the next ten years.
In October 2019, the central 28 m telescope of the H.E.S.S. experiment has been upgraded with a new camera. The camera is based on the FlashCam design which has been developed in view of a possible future implementation in the Medium-Sized Telescopes of the Cherenkov Telescope Array (CTA), with emphasis on cost and performance optimization and on reliability. The fully digital design of the trigger and readout system makes it possible to operate the camera at high event rates and to precisely adjust and understand the trigger system. The novel design of the front-end electronics achieves a dynamic range of over 3,000 photoelectrons with only one electronics readout circuit per pixel. Here we report on the performance parameters of the camera obtained during the first year of operation in the field, including operational stability and optimization of calibration algorithms.
A Silicon Photomultiplier (SiPM)-based photodetector is being built to demonstrate its feasibility for an alternative silicon-based camera design for the Large Size Telescope (LST) of the Cherenkov Telescope Array. It has been designed to match the s ize of the standard Photomultiplier Tube (PMT) cluster unit and to be compatible with mechanics, electronics and focal plane optics of the first LST camera. Here, we describe the overall SiPM cluster design along with the main differences with respect to the currently used PMT cluster unit. The fast electronics of the SiPM pixel and its layout are also presented. In order to derive the best working condition for the final unit, we measured the SiPM performances in terms of gain, photo-detection efficiency and cross-talk. One pixel, a unit of 14 SiPMs, has been built. We will discuss also some preliminary results regarding this device and we will highlight the future steps of this project.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا