ترغب بنشر مسار تعليمي؟ اضغط هنا

Ancillary services in Great Britain during the COVID-19 lockdown: a glimpse of the carbon-free future

68   0   0.0 ( 0 )
 نشر من قبل Luis Badesa
 تاريخ النشر 2021
والبحث باللغة English




اسأل ChatGPT حول البحث

The COVID-19 pandemic led to partial or total lockdowns in several countries during the first half of 2020, which in turn caused a depressed electricity demand. In Great Britain (GB), this low demand combined with large renewable output at times, created conditions that were not expected until renewable capacity increases to meet emissions targets in coming years. The GB system experienced periods of very high instantaneous penetration of non-synchronous renewables, compromising system stability due to the lack of inertia in the grid. In this paper, a detailed analysis of the consequences of the lockdown on the GB electricity system is provided, focusing on the ancillary services procured to guarantee stability. Ancillary-services costs increased by {pounds}200m in the months of May to July 2020 compared to the same period in 2019 (a threefold increase), highlighting the importance of ancillary services in low-carbon systems. Furthermore, a frequency-secured scheduling model is used in the present paper to showcase the future trends that GB is expected to experience, as penetration of renewables increases on the road to net-zero emissions by 2050. Several sensitivities are considered, demonstrating that the share of total operating costs represented by ancillary services could reach 35%.

قيم البحث

اقرأ أيضاً

Many of the control policies that were put into place during the Covid-19 pandemic had a common goal: to flatten the curve of the number of infected people so that its peak remains under a critical threshold. This letter considers the challenge of en gineering a strategy that enforces such a goal using control theory. We introduce a simple formulation of the optimal flattening problem, and provide a closed form solution.This is augmented through nonlinear closed loop tracking of the nominal solution, with the aim of ensuring close-to-optimal performance under uncertain conditions. A key contribution ofthis paper is to provide validation of the method with extensive and realistic simulations in a Covid-19 scenario, with particular focus on the case of Codogno - a small city in Northern Italy that has been among the most harshly hit by the pandemic.
The paper addresses the question of lives versus livelihood in an SIRD model augmented with a macroeconomic structure. The constraints on the availability of health facilities - both infrastructure and health workers determine the probability of rece iving treatment which is found to be higher for the patients with severe infection than the patients with mild infection for the specific parametric configuration of the paper. Distinguishing between two types of direct intervention policy - hard lockdown and soft lockdown, the study derives alternative policy options available to the government. The study further indicates that the soft lockdown policy is optimal from a public policy perspective under the specific parametric configuration considered in this paper.
In response to the COVID-19 pandemic, National governments have applied lockdown restrictions to reduce the infection rate. We perform a massive analysis on near real-time Italian data provided by Facebook to investigate how lockdown strategies affec t economic conditions of individuals and local governments. We model the change in mobility as an exogenous shock similar to a natural disaster. We identify two ways through which mobility restrictions affect Italian citizens. First, we find that the impact of lockdown is stronger in municipalities with higher fiscal capacity. Second, we find a segregation effect, since mobility restrictions are stronger in municipalities for which inequality is higher and where individuals have lower income per capita.
Frequency response and voltage support are vital ancillary services for power grids. In this paper, we design and experimentally validate a real-time control framework for battery energy storage systems (BESSs) to provide ancillary services to power grids. The objective of the control system is to utilize the full capability of the BESSs to provide ancillary services. We take the voltage-dependent capability curve of the DC-AC converter and the security requirements of BESSs as constraints of the control system. The initial power set-points are obtained based on the droop control approach. To guarantee the feasibility of the power set-points with respect to both the converter capability and BESS security constraints, the final power set-points calculation is formulated as a nonconvex optimization problem. A convex and computationally efficient reformulation of the original control problem is then proposed. We prove that the proposed convex optimization gives the global optimal solution to the original nonconvex problem. We improve the computational performance of this algorithm by discretizing the feasible region of the optimization model. We achieve a 100 ms update time of the controller setpoint computation in the experimental validation of the utility-scale 720 kVA / 560 kWh BESS on the EPFL campus.
The electric power grid is a complex cyberphysical energy system (CPES) in which information and communication technologies (ICT) are integrated into the operations and services of the power grid infrastructure. The growing number of Internet-of-thin gs (IoT) high-wattage appliances, such as air conditioners and electric vehicles, being connected to the power grid, together with the high dependence of ICT and control interfaces, make CPES vulnerable to high-impact, low-probability load-changing cyberattacks. Moreover, the side-effects of the COVID-19 pandemic demonstrate a modification of electricity consumption patterns with utilities experiencing significant net-load and peak reductions. These unusual sustained low load demand conditions could be leveraged by adversaries to cause frequency instabilities in CPES by compromising hundreds of thousands of IoT-connected high-wattage loads. This paper presents a feasibility study of the impacts of load-changing attacks on CPES during the low loading conditions caused by the lockdown measures implemented during the COVID-19 pandemic. The load demand reductions caused by the lockdown measures are analyzed using dynamic mode decomposition (DMD), focusing on the March-to-July 2020 period and the New York region as the most impacted time period and location in terms of load reduction due to the lockdowns being in full execution. Our feasibility study evaluates load-changing attack scenarios using real load consumption data from the New York Independent System Operator (NYISO) and shows that an attacker with sufficient knowledge and resources could be capable of producing frequency stability problems, with frequency excursions going up to 60.5 Hz and 63.4 Hz, when no mitigation measures are taken.