ترغب بنشر مسار تعليمي؟ اضغط هنا

Paschen curve for a PCB trace in low vacuum

125   0   0.0 ( 0 )
 نشر من قبل Nikolay Atanov
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

For one PCB trace region, where bare high voltage trace goes near GND pad, we estimated an electrical breakdown voltage in low vacuum using simplified geometrical model under some assumptions. Experimental measurement of Paschen curve for the PCB board considered was proceed in pressure range from 2x10-3 mbar to 25 mbar.

قيم البحث

اقرأ أيضاً

The wide application of the modern resonant measurement techniques makes all the steps of the measuring process, including data acquisition more efficient and reliable. Here we investigate the multidimensional space of the parameters to determine the optimum span for resonant measurements. The study concentrated on experimental systems with standard performance and capabilities. We determine the range of the optimum span for the resonant frequency and quality factor by simulating and fitting resonant curves with different levels of asymmetry.
We studied noise properties of microwave signals transmitted through the cryogenic resonator. The experiments were performed with the 11.342 GHz sapphire loaded cavity resonator cooled to 6.2 K. Based on the measured transmission coefficient of the c ryogenic resonator we computed its noise suppression function. This was done via Monte-Carlo simulations some details of which are discussed in this Letter. Next, we measured technical fluctuations of a signal incident on the cryogenic resonator. Having processed these data with the previously computed noise filtering template we inferred noise spectra of the transmitted signal. We found that spectral densities of both phase and amplitude fluctuations of the transmitted signal were close to the thermal noise limit of -180 dB/Hz at Fourier frequencies F $ge$ 10 kHz. Such thermal noise limited microwaves allow more precise tests of special relativity and could be useful at some stages of quantum signal processing.
High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffusion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the scintillation region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.
Although quantum mechanics (QM) and quantum field theory (QFT) are highly successful, the seemingly simplest state -- vacuum -- remains mysterious. While the LHC experiments are expected to clarify basic questions on the structure of QFT vacuum, much can still be done at lower energies as well. For instance, experiments like PVLAS try to reach extremely high sensitivities, in their attempt to observe the effects of the interaction of visible or near-visible photons with intense magnetic fields -- a process which becomes possible in quantum electrodynamics (QED) thanks to the vacuum fluctuations of the electronic field, and which is akin to photon-photon scattering. PVLAS is now close to data-taking and if it reaches the required sensitivity, it could provide important information on QED vacuum. PVLAS and other similar experiments face great challenges as they try to measure an extremely minute effect. However, raising the photon energy greatly increases the photon-photon cross-section, and gamma rays could help extract much more information from the observed light-light scattering. Here we discuss an experimental design to measure photon-photon scattering close to the peak of the photon-photon cross-section, that could fit in the proposed construction of an FEL facility at the Cabibbo Lab near Frascati (Rome, Italy).
Upon inclusion of collisions, the speed-limited particle-in-cell (SLPIC) simulation method successfully computed the Paschen curve for argon. The simulations modelled an electron cascade across an argon-filled capacitor, including electron-neutral io nization, electron-neutral elastic collisions, electron-neutral excitation, and ion-induced secondary-electron emission. In electrical breakdown, the timescale difference between ion and electron motion makes traditional particle-in-cell (PIC) methods computationally slow. To decrease this timescale difference and speed up computation, we used SLPIC, a time-domain algorithm that limits the speed of the fastest electrons in the simulation. The SLPIC algorithm facilitates a straightforward, fully-kinetic treatment of dynamics, secondary emission, and collisions. SLPIC was as accurate as PIC, but ran up to 200 times faster. SLPIC accurately computed the Paschen curve for argon over three orders of magnitude in pressure.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا