ترغب بنشر مسار تعليمي؟ اضغط هنا

Quantitative Bioluminescence Tomography-guided System for Conformal Irradiation In Vivo

96   0   0.0 ( 0 )
 نشر من قبل Xiangkun Xu
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Although cone-beam CT (CBCT) has been used to guide irradiation for pre-clinical radiotherapy(RT) research, it is limited to localize soft tissue target especially in a low imaging contrast environment. Knowledge of target shape is a fundamental need for RT. Without such information to guide radiation, normal tissue can be irradiated unnecessarily, leading to experimental uncertainties. Recognition of this need led us to develop quantitative bioluminescence tomography (QBLT), which provides strong imaging contrast to localize optical targets. We demonstrated its capability of guiding conformal RT using an orthotopic bioluminescent glioblastoma (GBM) model. With multi-projection and multi-spectral bioluminescence imaging and a novel spectral derivative method, our QBLT system is able to reconstruct GBM with localization accuracy <1mm. An optimal threshold was determined to delineate QBLT reconstructed gross target volume (GTV_{QBLT}), which provides the best overlap between the GTV_{QBLT} and CBCT contrast labeled GBM (GTV), used as the ground truth for the GBM volume. To account for the uncertainty of QBLT in target localization and volume delineation, we also innovated a margin design; a 0.5mm margin was determined and added to GTV_{QBLT} to form a planning target volume (PTV_{QBLT}), which largely improved tumor coverage from 75% (0mm margin) to 98% and the corresponding variation (n=10) of the tumor coverage was significantly reduced. Moreover, with prescribed dose 5Gy covering 95% of PTV_{QBLT}, QBLT-guided 7-field conformal RT can irradiate 99.4 pm 1.0% of GTV vs. 65.5 pm 18.5% with conventional single field irradiation (n=10). Our QBLT-guided system provides a unique opportunity for researchers to guide irradiation for soft tissue targets and increase rigorous and reproducibility of scientific discovery.



قيم البحث

اقرأ أيضاً

Optical coherence tomography (OCT) is a widely used imaging technique in the micrometer regime, which gained accelerating interest in medical imaging %and material testing in the last twenty years. In up-to-date OCT literature [5,6] certain simplifyi ng assumptions are made for the reconstructions, but for many applications a more realistic description of the OCT imaging process is of interest. In mathematical models, for example, the incident angle of light onto the sample is usually neglected or %although having a huge impact on the laser power inside the sample is usually neglected or a plane wave description for the light-sample interaction in OCT is used, which ignores almost completely the occurring effects within an OCT measurement process. In this article, we make a first step to a quantitative model by considering the measured intensity as a combination of back-scattered Gaussian beams affected by the system. In contrast to the standard plane wave simplification, the presented model includes system relevant parameters such as the position of the focus and the spot size of the incident laser beam, which allow a precise prediction of the OCT data and therefore ultimately serves as a forward model. The accuracy of the proposed model - after calibration of all necessary system parameters - is illustrated by simulations and validated by a comparison with experimental data obtained from a 1300nm swept-source OCT system.
We have developed a multimodal photoacoustic remote sensing (PARS) microscope combined with swept source optical coherence tomography for in vivo, non-contact retinal imaging. Building on the proven strength of multiwavelength PARS imaging, the syste m is applied for estimating retinal oxygen saturation in the rat retina. The capability of the technology is demonstrated by imaging both microanatomy and the microvasculature of the retina in vivo. To our knowledge this is the first time a non-contact photoacoustic imaging technique is employed for in vivo oxygen saturation measurement in the retina.
139 - Hui Li , Boxiao Liu , Yongfu Li 2018
A high accuracy and high sensitivity system architecture is proposed for the read-out circuit of electrical impedance tomography system-on-chip. The switched ratiometric technique is applied in the proposed architecture. The proposed system architect ure minimizes the device noise by processing signals from both read-out electrodes and the stimulus. The quantized signals are post-processed in the digital processing unit for proper signal demodulation and impedance ratio calculation. Our proposed architecture improves the sensitivity of the read-out circuit, cancels out the gain fluctuations in the system, and overcomes the effects of motion artifacts on measurements.
A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 Italian project. One of the main goals of this projec t is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic modules of our lung-CAD system, a dot-enhancement filter for nodule candidate selection and a neural classifier for false-positive finding reduction, are described. The system was designed and tested for both internal and sub-pleural nodules. The results obtained on the collected database of low-dose thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.
Early diagnosis of ocular diseases improves the understanding of pathophysiology and helps with accurate monitoring and effective treatment. Advanced multimodal ocular imaging platforms play a crucial role in the visualization of the ocular component s and provide clinicians with a valuable tool for evaluating different eye diseases. Here, for the first time, we present a non-contact, multimodal photoacoustic remote sensing (PARS) microscopy and swept-source optical coherence tomography (SS-OCT) for in-vivo functional and structural imaging of the eye. The system provides complementary imaging contrasts of optical absorption and optical scattering and is used for non-contact, in-vivo imaging of the murine eye. Results of vasculature and structural imaging as well as melanin content in the retinal pigment epithelium (RPE) layer are presented. Multiwavelength PARS microscopy using Stimulated Raman Scattering (SRS) is applied for the first time, to provide non-contact oxygen saturation estimation in the ocular tissue. The reported work may be a major step toward clinical translation of ophthalmic technologies and has the potential to advance the diagnosis and treatment of ocular diseases.