ترغب بنشر مسار تعليمي؟ اضغط هنا

Broadband model-based inversion enables optoacoustic microscopy beyond the acoustic diffraction limit

74   0   0.0 ( 0 )
 نشر من قبل Xose Luis Dean-Ben
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Acoustic-resolution optoacoustic microscopy (AR-OAM) retrieves anatomical and functional contrast from living tissues at depths not reachable with optical microscopy. The imaging performance of AR-OAM has been advanced with image reconstruction algorithms providing high lateral resolution ultimately limited by acoustic diffraction. In this work, we suggest a new model-based framework efficiently exploiting scanning symmetries for high-resolution reconstruction of AR-OAM images. The model accurately accounts for the spatial impulse response and large detection bandwidth of a spherical polyvinylidene difluoride sensor, which facilitates significantly outperforming synthetic aperture focusing technique commonly employed in AR-OAM image reconstruction in terms of image contrast and resolution. Furthermore, reconstructions based on L1-norm regularization enabled resolving structures indistinguishable with other methods, which was confirmed by numerical simulations as well as phantom and in vivo experiments. The achieved performance demonstrates the applicability of AR-OAM as a super-resolution imaging method capable of breaking through the limits imposed by acoustic diffraction, thus opening unprecedented capabilities for the microscopic interrogation of optically opaque tissues in preclinical and clinical studies.

قيم البحث

اقرأ أيضاً

Acoustic impedance mismatches between soft tissues and bones are known to result in strong aberrations in optoacoustic and ultrasound images. Of particular importance are the severe distortions introduced by the human skull, impeding transcranial bra in imaging with these modalities. While modelling of ultrasound propagation through the skull may in principle help correcting for some of the skull-induced aberrations, these approaches are commonly challenged by the highly heterogeneous and dispersive acoustic properties of the skull and lack of exact knowledge on its geometry and internal structure. Here we demonstrate that the spatio-temporal properties of the acoustic distortions induced by the skull are preserved for signal sources generated at neighboring intracranial locations by means of optoacoustic excitation. This optoacoustic memory effect is exploited for building a three-dimensional model accurately describing the generation, propagation and detection of time-resolved broadband optoacoustic waveforms traversing the skull. The memory-based model-based inversion is then shown to accurately recover the optical absorption distribution inside the skull with spatial resolution and image quality comparable to those attained in skull-free medium.
Quantum noise places a fundamental limit on the per photon sensitivity attainable in optical measurements. This limit is of particular importance in biological measurements, where the optical power must be constrained to avoid damage to the specimen. By using non-classically correlated light, we demonstrated that the quantum limit can be surpassed in biological measurements. Quantum enhanced microrheology was performed within yeast cells by tracking naturally occurring lipid granules with sensitivity 2.4 dB beyond the quantum noise limit. The viscoelastic properties of the cytoplasm could thereby be determined with a 64% improved measurement rate. This demonstration paves the way to apply quantum resources broadly in a biological context.
Optical tomographic imaging of biological specimen bases its reliability on the combination of both accurate experimental measures and advanced computational techniques. In general, due to high scattering and absorption in most of the tissues, multi view geometries are required to reduce diffuse halo and blurring in the reconstructions. Scanning processes are used to acquire the data but they inevitably introduces perturbation, negating the assumption of aligned measures. Here we propose an innovative, registration free, imaging protocol implemented to image a human tumor spheroid at mesoscopic regime. The technique relies on the calculation of autocorrelation sinogram and object autocorrelation, finalizing the tomographic reconstruction via a three dimensional Gerchberg Saxton algorithm that retrieves the missing phase information. Our method is conceptually simple and focuses on single image acquisition, regardless of the specimen position in the camera plane. We demonstrate increased deep resolution abilities, not achievable with the current approaches, rendering the data alignment process obsolete.
Localization-based imaging has revolutionized fluorescence optical microscopy and has also enabled unprecedented ultrasound images of microvascular structures in deep tissues. Herein, we introduce a new concept of localization optoacoustic tomography (LOAT) that employs rapid sequential acquisition of three-dimensional optoacoustic images from flowing absorbing particles. We show that the new method enables breaking through the spatial resolution barrier of acoustic diffraction while further enhancing the visibility of structures under limited-view tomographic conditions. Given the intrinsic sensitivity of optoacoustics to multiple hemodynamic and oxygenation parameters, LOAT may enable new level of performance in studying functional and anatomical alterations of microcirculation.
A theoretical model of the influence of detection bandwidth properties on observed line shapes in laser absorption spectroscopy is described. The model predicts artificial frequency shifts, extra broadenings and line asymmetries which must be taken i nto account in order to obtain accurate central frequencies and other spectroscopic parameters. This reveals sources of systematic effects most probably underestimated so far potentially affecting spectroscopic measurements. This may impact many fields of research, from atmospheric and interstellar physics to precision spectroscopic measurements devoted to metrological applications, tests of quantum electrodynamics or other fundamental laws of nature. Our theoretical model is validated by linear absorption experiments performed on H2O and NH3 molecular lines recorded by precision laser spectroscopy in two distinct spectral regions, near- and mid-infrared. Possible means of recovering original line shape parameters or experimental conditions under which the detection bandwidth has a negligible impact, given a targeted accuracy, are proposed. Particular emphasis is put on the detection bandwidth adjustments required to use such high-quality molecular spectra for a spectroscopic determination of the Boltzmann constant at the 1 ppm level of accuracy.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا