ترغب بنشر مسار تعليمي؟ اضغط هنا

Correction Method for the Readout Saturation of the DAMPE Calorimeter

435   0   0.0 ( 0 )
 نشر من قبل Chuan Yue
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The DArk Matter Particle Explorer (DAMPE) is a space-borne high energy cosmic-ray and $gamma$-ray detector which operates smoothly since the launch on December 17, 2015. The bismuth germanium oxide (BGO) calorimeter is one of the key sub-detectors of DAMPE used for energy measurement and electron proton identification. For events with total energy deposit higher than decades of TeV, the readouts of PMTs coupled on the BGO crystals would become saturated, which results in an underestimation of the energy measurement. Based on detailed simulations, we develop a correction method for the saturation effect according to the shower development topologies and energies measured by neighbouring BGO crystals. The verification with simulated and on-orbit events shows that this method can well reconstruct the energy deposit in the saturated BGO crystal.

قيم البحث

اقرأ أيضاً

A BGO electromagnetic calorimeter (ECAL) is built for the DArk Matter Particle Explorer (DAMPE) mission. The effect of temperature on the BGO ECAL was investigated with a thermal vacuum experiment. The light output of a BGO crystal depends on tempera ture significantly. The temperature coefficient of each BGO crystal bar has been calibrated, and a correction method is also presented in this paper.
The BGO calorimeter, which provides a wide measurement range of the primary cosmic ray spectrum, is a key sub-detector of Dark Matter Particle Explorer (DAMPE). The readout electronics of calorimeter consists of 16 pieces of Actel ProASIC Plus FLASH- based FPGA, of which the design-level flip-flops and embedded block RAMs are single event upset (SEU) sensitive in the harsh space environment. Therefore to comply with radiation hardness assurance (RHA), SEU mitigation methods, including partial triple modular redundancy (TMR), CRC checksum, and multi-domain reset are analyzed and tested by the heavy-ion beam test. Composed of multi-level redundancy, a FPGA design with the characteristics of SEU tolerance and low resource consumption is implemented for the readout electronics.
DAMPE is a space-based mission designed as a high energy particle detector measuring cosmic-rays and $gamma-$rays which was successfully launched on Dec.17, 2015. The BGO electromagnetic calorimeter is one of the key sub-detectors of DAMPE for energy measurement of electromagnetic showers produced by $e^{pm}/{gamma}$. Due to energy loss in dead material and energy leakage outside the calorimeter, the deposited energy in BGO underestimates the primary energy of incident $e^{pm}/{gamma}$. In this paper, based on detailed MC simulations, a parameterized energy correction method using the lateral and longitudinal information of electromagnetic showers has been studied and verified with data of electron beam test at CERN. The measurements of energy linearity and resolution are significantly improved by applying this correction method for electromagnetic showers.
360 - N.Atanov , V.Baranov , L.Baldini 2019
The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two type s of modules: 1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; 2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of $200 text{M}text{Hz}$ with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of $20 text{krads}$, neutron flux of $10^{12} mathrm{n}(1 text{MeVeq})/text{cm}^2$, magnetic field of $1 text{T}$ and in vacuum level of $10^{-4} text{Torr}$. A description of the readout system and qualification tests is reported.
The SiD collaboration is developing a Si-W sampling electromagnetic calorimeter, with anticipated application for the International Linear Collider. Assembling the modules for such a detector will involve special bonding technologies for the intercon nections, especially for attaching a silicon detector wafer to a flex cable readout bus. We review the interconnect technologies involved, including oxidation removal processes, pad surface preparation, solder ball selection and placement, and bond quality assurance. Our results show that solder ball bonding is a promising technique for the Si-W ECAL, and unresolved issues are being addressed.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا