The new Oslo Scintillator Array (OSCAR) has been commissioned at the Oslo Cyclotron Laboratory (OCL). It consists of 30 large volume (diameter 3.5 x 8 inches) LaBr$_3$(Ce) detectors that are used for $gamma$-ray spectroscopy. The response functions for incident $gamma$-rays up to 20 MeV are simulated with $texttt{Geant4}$. In addition, the resolution, and the total and full-energy peak efficiencies are extracted. The results are in very good agreement with measurements from calibration sources and experimentally obtained mono-energetic in-beam $gamma$-ray spectra.



قيم البحث

اقرأ أيضاً

It is challenging to achieve high precision energy resolution for large liquid scintillator detectors. Energy non-uniformity is one of the main obstacles. To surmount it, a calibration-data driven method was developed previously to reconstruct event energy in the JUNO experiment. In this paper, we investigated the choice of calibration sources thoroughly, optimized the calibration positions and corrected the residual detector azimuthal asymmetry. All these efforts lead to a reduction of the energy non-uniformity near the detector boundary, from about 0.64% to 0.38%. And within the fiducial volume of the detector it is improved from 0.3% to 0.17%. As a result the energy resolution could be further improved.
In this paper we report studies of the Fermi potential and loss per bounce of ultracold neutron (UCN) on a deuterated scintillator (Eljen-299-02D). These UCN properties of the scintillator enables a wide variety of applications in fundamental neutron research.
The Lanthanum Halide scintillator detectors have been widely used for nuclear spectroscopy experiments because of their excellent energy and time resolutions. Despite having these advantages, the intrinsic alpha and beta contaminations in these scint illators pose a severe limitation in their usage in rare-event detections. In the present work, pulse shape discrimination (PSD) with a fast digitizer has been shown to be an efficient method to separate the effect of alpha contamination from the spectrum. The shape of the beta spectrum has been generated with the help of Monte Carlo based simulation code, and its contribution has been eliminated from the spectrum. The reduction in the background events generated by both intrinsic beta and alpha activities has been demonstrated. The present study will encourage the application of these detectors in low cross-section measurement experiments relevant to nuclear astrophysics.
The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) , composed of two small satellites, is a new mission to monitor the Gamma-Ray Bursts (GRBs) coincident with gravitational wave events with a FOV of 100% all-sky. G ECAM detects and localizes 6 keV-5 MeV GRBs via 25 compact and novel Gamma-Ray Detectors (GRDs). Each GRD module is comprised of a LaBr3:Ce scintillator, SiPM array and preamplifier. A large dynamic range is achieved by the high gain and low gain channels of the preamplifier. This article discusses the performance of a GRD prototype which includes a set of radioactive sources in the range of 5.9-1332.5 keV. The energy resolution and energy to ADC channel conversion of the GRD module are also discussed. The typical energy resolution is 5.3% at 662 keV (FWHM) which meets the relevant requirements (< 8% at 662 keV). The energy calibration capability is evaluated by the measured intrinsic activity of LaBr3:Ce and Geant4 simulation results. The test results demonstrate the feasibility of the GECAM GRD design.
119 - T. Masuda , T. Hiraki , H. Kaino 2018
This paper reports on the demonstration of a high-rate energy measurement technique using a thin depletion layer silicon avalanche photodiode (Si-APD). A dedicated amplitude-to-time converter is developed to realize simultaneous energy and timing mea surement in a high rate condition. The energy response of the system is systematically studied by using monochromatic X-ray beam with an incident energy ranging from 6 to 33 keV. The obtained energy spectra contain clear peaks and tail distributions. The peak fraction monotonously decreases as the incident photon energy increases. This phenomenon can be explained by considering the distribution of the energy deposit in silicon, which is investigated by using a Monte Carlo simulation.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا