ترغب بنشر مسار تعليمي؟ اضغط هنا

Method to Determine the Closed-Loop Precision of Resonant Sensors from Open-Loop Measurements

55   0   0.0 ( 0 )
 نشر من قبل Tomas Manzaneque
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Resonant sensors determine a sensed parameter by measuring the resonance frequency of a resonator. For fast continuous sensing, it is desirable to operate resonant sensors in a closed-loop configuration, where a feedback loop ensures that the resonator is always actuated near its resonance frequency, so that the precision is maximized even in the presence of drifts or fluctuations of the resonance frequency. However, in a closed-loop configuration, the precision is not only determined by the resonator itself, but also by the feedback loop, even if the feedback circuit is noiseless. Therefore, to characterize the intrinsic precision of resonant sensors, the open-loop configuration is often employed. To link these measurements to the actual closed-loop performance of the resonator, it is desirable to have a relation that determines the closed-loop precision of the resonator from open-loop characterisation data. In this work, we present a methodology to estimate the closed-loop resonant sensor precision by relying only on an open-loop characterization of the resonator. The procedure is beneficial for fast performance estimation and benchmarking of resonant sensors, because it does not require actual closed-loop sensor operation, thus being independent on the particular implementation of the feedback loop. We validate the methodology experimentally by determining the closed-loop precision of a mechanical resonator from an open-loop measurement and comparing this to an actual closed-loop measurement.



قيم البحث

اقرأ أيضاً

64 - Weiwei Hu , Jun Liu , Zhu Wang 2021
This paper is concerned with a bilinear control problem for enhancing convection-cooling via an incompressible velocity field. Both optimal open-loop control and closed-loop feedback control designs are addressed. First and second order optimality co nditions for characterizing the optimal solution are discussed. In particular, the method of instantaneous control is applied to establish the feedback laws. Moreover, the construction of feedback laws is also investigated by directly utilizing the optimality system with appropriate numerical discretization schemes. Computationally, it is much easier to implement the closed-loop feedback control than the optimal open-loop control, as the latter requires to solve the state equations forward in time, coupled with the adjoint equations backward in time together with a nonlinear optimality condition. Rigorous analysis and numerical experiments are presented to demonstrate our ideas and validate the efficacy of the control designs.
We present the closed loop approach to linear nonequilibrium thermodynamics considering a generic heat engine dissipatively connected to two temperature baths. The system is usually quite generally characterized by two parameters: the output power $P $ and the conversion efficiency $eta$, to which we add a third one, the working frequency $omega$. We establish that a detailed understanding of the effects of the dissipative coupling on the energy conversion process, necessitates the knowledge of only two quantities: the systems feedback factor $beta$ and its open-loop gain $A_{0}$, the product of which, $A_{0}beta$, characterizes the interplay between the efficiency, the output power and the operating rate of the system. By placing thermodynamics analysis on a higher level of abstraction, the feedback loop approach provides a versatile and economical, hence a very efficient, tool for the study of emph{any} conversion engine operation for which a feedback factor may be defined.
Future electron-position colliders, such as CEPC and FCC-ee, have the capability to dramatically improve the experimental precision for W and Z-boson masses and couplings. This would enable indirect probes of physics beyond the Standard Model at mult i-TeV scales. For this purpose, one must complement the experimental measurements with equally precise calculations for the theoretical predictions of these quantities within the Standard Model, including three-loop electroweak corrections. This article reports on the calculation of a subset of these corrections, stemming from diagrams with three closed fermion loops to the following quantities: the prediction of the W-boson mass from the Fermi constant, the effective weak mixing angle, and partial and total widths of the Z boson. The numerical size of these corrections is relatively modest, but non-negligible compared to the precision targets of future colliders. In passing, an error is identified in previous results for the two-loop corrections to the Z width, with a small yet non-zero numerical impact.
Superconducting qubits are a promising platform for building a larger-scale quantum processor capable of solving otherwise intractable problems. In order for the processor to reach practical viability, the gate errors need to be further suppressed an d remain stable for extended periods of time. With recent advances in qubit control, both single- and two-qubit gate fidelities are now in many cases limited by the coherence times of the qubits. Here we experimentally employ closed-loop feedback to stabilize the frequency fluctuations of a superconducting transmon qubit, thereby increasing its coherence time by 26% and reducing the single-qubit error rate from $(8.5 pm 2.1)times 10^{-4}$ to $(5.9 pm 0.7)times 10^{-4}$. Importantly, the resulting high-fidelity operation remains effective even away from the qubit flux-noise insensitive point, significantly increasing the frequency bandwidth over which the qubit can be operated with high fidelity. This approach is helpful in large qubit grids, where frequency crowding and parasitic interactions between the qubits limit their performance.
121 - W. Langbein 2018
Recently, sensors with resonances at exceptional points (EPs) have been suggested to have a vastly improved sensitivity due to the extraordinary scaling of the complex frequency splitting of the $n$ initially degenerate modes with the $n$-th root of the perturbation. We show here that the resulting quantum-limited signal to noise at EPs is proportional to the perturbation, and comparable to other sensors, thus providing the same precision. The complex frequency splitting close to EPs is therefore not suited to estimate the precision of EP sensors. The underlying reason of this counter-intuitive result is that the mode fields, described by the eigenvectors, are equal for all modes at the EP, and are strongly changing with the perturbation.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا