ترغب بنشر مسار تعليمي؟ اضغط هنا

Cavity-enhanced non-destructive detection of atoms for an optical lattice clock

109   0   0.0 ( 0 )
 نشر من قبل William Bowden Mr
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We demonstrate a new method of cavity-enhanced non-destructive detection of atoms for a strontium optical lattice clock. The detection scheme is shown to be linear in atom number up to at least 10,000 atoms, to reject technical noise sources, to achieve signal to noise ratio close to the photon shot noise limit, to provide spatially uniform atom-cavity coupling, and to minimize inhomogeneous ac Stark shifts. These features enable detection of atoms with minimal perturbation to the atomic state, a critical step towards realizing an ultra-high-stability, quantum-enhanced optical lattice clock.



قيم البحث

اقرأ أيضاً

We present and implement a non-destructive detection scheme for the transition probability readout of an optical lattice clock. The scheme relies on a differential heterodyne measurement of the dispersive properties of lattice-trapped atoms enhanced by a high finesse cavity. By design, this scheme offers a 1st order rejection of the technical noise sources, an enhanced signal-to-noise ratio, and an homogeneous atom-cavity coupling. We theoretically show that this scheme is optimal with respect to the photon shot noise limit. We experimentally realize this detection scheme in an operational strontium optical lattice clock. The resolution is on the order of a few atoms with a photon scattering rate low enough to keep the atoms trapped after detection. This scheme opens the door to various different interrogations protocols, which reduce the frequency instability, including atom recycling, zero-dead time clocks with a fast repetition rate, and sub quantum projection noise frequency stability.
We report a frequency measurement of the 1S0-3P0 transition of 87Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical clocks wi th neutral atoms in free fall. Two previous measurements of this transition were found to disagree by about 2x10^{-13}, i.e. almost four times the combined error bar, instilling doubt on the potential of optical lattice clocks to perform at a high accuracy level. In perfect agreement with one of these two values, our measurement essentially dissipates this doubt.
214 - Xavier Baillard 2007
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is comparable to t he frequency difference between the various primary standards throughout the world. This measurement is in excellent agreement with a previous one of similar accuracy.
188 - Xavier Baillard 2007
We report the first accuracy evaluation of an optical lattice clock based on the 1S0 - 3P0 transition of an alkaline earth boson, namely 88Sr atoms. This transition has been enabled using a static coupling magnetic field. The clock frequency is deter mined to be 429 228 066 418 009(32) Hz. The isotopic shift between 87Sr and 88Sr is 62 188 135 Hz with fractional uncertainty 5.10^{-7}. We discuss the conditions necessary to reach a clock accuracy of 10^{-17} or less using this scheme.
Experiments involving optical traps often require careful control of the ac Stark shifts induced by strong confining light fields. By carefully balancing light shifts between two atomic states of interest, optical traps at the magic wavelength have b een especially effective at suppressing deleterious effects stemming from such shifts. Highlighting the power of this technique, optical clocks today exploit Lamb-Dicke confinement in magic-wavelength optical traps, in some cases realizing shift cancellation at the ten parts per billion level. Theory and empirical measurements can be used at varying levels of precision to determine the magic wavelength where shift cancellation occurs. However, lasers exhibit background spectra from amplified spontaneous emission or other lasing modes which can easily contaminate measurement of the magic wavelength and its reproducibility in other experiments or conditions. Indeed, residual light shifts from laser background have plagued optical lattice clock measurements for years. In this work, we develop a simple theoretical model allowing prediction of light shifts from measured background spectra. We demonstrate good agreement between this model and measurements of the background light shift from an amplified diode laser in an Yb optical lattice clock. Additionally, we model and experimentally characterize the filtering effect of a volume Bragg grating bandpass filter, demonstrating that application of the filter can reduce background light shifts from amplified spontaneous emission well below the $10^{-18}$ fractional clock frequency level. This demonstration is corroborated by direct clock comparisons between a filtered amplified diode laser and a filtered titanium:sapphire laser.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا