ترغب بنشر مسار تعليمي؟ اضغط هنا

Calibrating Iodine Cells for Precise Radial Velocities

80   0   0.0 ( 0 )
 نشر من قبل Sharon Xuesong Wang
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

High fidelity iodine spectra provide the wavelength and instrument calibration needed to extract precise radial velocities (RVs) from stellar spectral observations taken through iodine cells. Such iodine spectra are usually taken by a Fourier Transform Spectrometer (FTS). In this work, we investigated the reason behind the discrepancy between two FTS spectra of the iodine cell used for precise RV work with the High Resolution Spectrograph (HRS) at the Hobby-Eberly Telescope. We concluded that the discrepancy between the two HRS FTS spectra was due to temperature changes of the iodine cell. Our work demonstrated that the ultra-high resolution spectra taken by the TS12 arm of the Tull Spectrograph One at McDonald Observatory are of similar quality to the FTS spectra and thus can be used to validate the FTS spectra. Using the software IodineSpec5, which computes the iodine absorption lines at different temperatures, we concluded that the HET/HRS cell was most likely not at its nominal operating temperature of 70 degree Celsius during its FTS scan at NIST or at the TS12 measurement. We found that extremely high resolution echelle spectra (R>200,000) can validate and diagnose deficiencies in FTS spectra. We also recommend best practices for temperature control and nightly calibration of iodine cells.

قيم البحث

اقرأ أيضاً

We characterized the effects of telluric absorption lines on the radial velocity (RV) precision of stellar spectra taken through an iodine cell. To isolate the effects induced by telluric contamination from other stellar, instrumental, or numerical s ystematic RV noise, we extracted RVs from simulated iodine calibrated spectra of three RV standard stars regularly observed by Keck/HIRES. We add in water absorption lines according to measured precipitable water vapor (PWV) contents over a one-year period. We concluded that telluric contamination introduces additional RV noise and spurious periodic signals on the level of 10-20 cm/s, consistent with similar previous studies. Our findings show that forward modeling the telluric lines effectively recovers the RV precision and accuracy, with no prior knowledge of the PWV needed. Such a recovery is less effective when the water absorption lines are relatively deep in the stellar template used in the forward modeling. Overall, telluric contamination plays an insignificant role for typical iodine-calibrated RV programs aiming at ~1-2 m/s, but we recommend adding modeling of telluric lines and taking stellar template observations on nights with low humidity for programs aiming to achieve sub-m/s precision.
The EXtreme PREcision Spectrograph (EXPRES) is an environmentally stabilized, fiber-fed, $R=137,500$, optical spectrograph. It was recently commissioned at the 4.3-m Lowell Discovery Telescope (LDT) near Flagstaff, Arizona. The spectrograph was desig ned with a target radial-velocity (RV) precision of 30$mathrm{~cm~s^{-1}}$. In addition to instrumental innovations, the EXPRES pipeline, presented here, is the first for an on-sky, optical, fiber-fed spectrograph to employ many novel techniques---including an extended flat fiber used for wavelength-dependent quantum efficiency characterization of the CCD, a flat-relative optimal extraction algorithm, chromatic barycentric corrections, chromatic calibration offsets, and an ultra-precise laser frequency comb for wavelength calibration. We describe the reduction, calibration, and radial-velocity analysis pipeline used for EXPRES and present an example of our current sub-meter-per-second RV measurement precision, which reaches a formal, single-measurement error of 0.3$mathrm{~m~s^{-1}}$ for an observation with a per-pixel signal-to-noise ratio of 250. These velocities yield an orbital solution on the known exoplanet host 51 Peg that matches literature values with a residual RMS of 0.895$mathrm{~m~s^{-1}}$.
120 - M. J. Hobson 2021
SPIRou is a near-infrared (nIR) spectropolarimeter at the CFHT, covering the YJHK nIR spectral bands ($980-2350,mathrm{nm}$). We describe the development and current status of the SPIRou wavelength calibration in order to obtain precise radial veloci ties (RVs) in the nIR. We make use of a UNe hollow-cathode lamp and a Fabry-Perot etalon to calibrate the pixel-wavelength correspondence for SPIRou. Different methods are developed for identifying the hollow-cathode lines, for calibrating the wavelength dependence of the Fabry-Perot cavity width, and for combining the two calibrators. The hollow-cathode spectra alone do not provide a sufficiently accurate wavelength solution to meet the design requirements of an internal error of $mathrm{<0.45,m,s^{-1}}$, for an overall RV precision of $mathrm{1,m,s^{-1}}$. However, the combination with the Fabry-Perot spectra allows for significant improvements, leading to an internal error of $mathrm{sim 0.15,m,s^{-1}}$. We examine the inter-night stability, intra-night stability, and impact on the stellar RVs of the wavelength solution.
Context: The CARMENES survey is a high-precision radial velocity (RV) programme that aims to detect Earth-like planets orbiting low-mass stars. Aims: We develop least-squares fitting algorithms to derive the RVs and additional spectral diagnostics implemented in the SpEctrum Radial Velocity Analyser (SERVAL), a publicly available python code. Methods: We measured the RVs using high signal-to-noise templates created by coadding all available spectra of each star.We define the chromatic index as the RV gradient as a function of wavelength with the RVs measured in the echelle orders. Additionally, we computed the differential line width by correlating the fit residuals with the second derivative of the template to track variations in the stellar line width. Results: Using HARPS data, our SERVAL code achieves a RV precision at the level of 1m/s. Applying the chromatic index to CARMENES data of the active star YZ CMi, we identify apparent RV variations induced by stellar activity. The differential line width is found to be an alternative indicator to the commonly used full width half maximum. Conclusions: We find that at the red optical wavelengths (700--900 nm) obtained by the visual channel of CARMENES, the chromatic index is an excellent tool to investigate stellar active regions and to identify and perhaps even correct for activity-induced RV variations.
We present a method to optimize absorption cells for precise wavelength calibration in the near-infrared. We apply it to design and optimize methane isotopologue cells for precision radial velocity measurements in the K band. We also describe the con struction and installation of two such cells for the CSHELL spectrograph at NASAs IRTF. We have obtained their high-resolution laboratory spectra, which we can then use in precision radial velocity measurements and which can also have other applications. In terms of obtainable RV precision methane should out-perform other proposed cells, such as the ammonia cell ($^{14}$NH$_{3}$) recently demonstrated on CRIRES/VLT. The laboratory spectra of Ammonia and the Methane cells show strong absorption features in the H band that could also be exploited for precision Doppler measurements. We present spectra and preliminary radial velocity measurements obtained during our first-light run. These initial results show that a precision down to 20-30 m s$^{-1}$ can be obtained using a wavelength interval of only 5 nm in the K band and S/N$sim$150. This supports the prediction that a precision down to a few m s$^{-1}$ can be achieved on late M dwarfs using the new generation of NIR spectrographs, thus enabling the detection of terrestrial planets in their habitable zones. Doppler measurements in the NIR can also be used to mitigate the radial velocity jitter due to stellar activity enabling more efficient surveys on young active stars.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا