Clinical decision support systems (CDSS) will play an in-creasing role in improving the quality of medical care for critically ill patients. However, due to limitations in current informatics infrastructure, CDSS do not always have com-plete information on state of supporting physiologic monitor-ing devices, which can limit the input data available to CDSS. This is especially true in the use case of mechanical ventilation (MV), where current CDSS have no knowledge of critical ventilation settings, such as ventilation mode. To enable MV CDSS to make accurate recommendations related to ventilator mode, we developed a highly performant ma-chine learning model that is able to perform per-breath clas-sification of 5 of the most widely used ventilation modes in the USA with an average F1-score of 97.52%. We also show how our approach makes methodologic improvements over previous work and that it is highly robust to missing data caused by software/sensor error.

قيم البحث

اقرأ أيضاً

161 - C. Galbiati , A. Abba , P. Agnes 2020
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many coun tries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.
Owe to the recent advancements in Artificial Intelligence especially deep learning, many data-driven decision support systems have been implemented to facilitate medical doctors in delivering personalized care. We focus on the deep reinforcement lear ning (DRL) models in this paper. DRL models have demonstrated human-level or even superior performance in the tasks of computer vision and game playings, such as Go and Atari game. However, the adoption of deep reinforcement learning techniques in clinical decision optimization is still rare. We present the first survey that summarizes reinforcement learning algorithms with Deep Neural Networks (DNN) on clinical decision support. We also discuss some case studies, where different DRL algorithms were applied to address various clinical challenges. We further compare and contrast the advantages and limitations of various DRL algorithms and present a preliminary guide on how to choose the appropriate DRL algorithm for particular clinical applications.
The pervasive application of algorithmic decision-making is raising concerns on the risk of unintended bias in AI systems deployed in critical settings such as healthcare. The detection and mitigation of biased models is a very delicate task which sh ould be tackled with care and involving domain experts in the loop. In this paper we introduce FairLens, a methodology for discovering and explaining biases. We show how our tool can be used to audit a fictional commercial black-box model acting as a clinical decision support system. In this scenario, the healthcare facility experts can use FairLens on their own historical data to discover the models biases before incorporating it into the clinical decision flow. FairLens first stratifies the available patient data according to attributes such as age, ethnicity, gender and insurance; it then assesses the model performance on such subgroups of patients identifying those in need of expert evaluation. Finally, building on recent state-of-the-art XAI (eXplainable Artificial Intelligence) techniques, FairLens explains which elements in patients clinical history drive the model error in the selected subgroup. Therefore, FairLens allows experts to investigate whether to trust the model and to spotlight group-specific biases that might constitute potential fairness issues.
HEV is a low-cost, versatile, high-quality ventilator, which has been designed in response to the COVID-19 pandemic. The ventilator is intended to be used both in and out of hospital intensive care units, and for both invasive and non-invasive ventil ation. The hardware can be complemented with an external turbine for use in regions where compressed air supplies are not reliably available. The standard modes provided include PC-A/C(Pressure Assist Control),PC-A/C-PRVC(Pressure Regulated Volume Control), PC-PSV (Pressure Support Ventilation) and CPAP (Continuous Positive airway pressure). HEV is designed to support remote training and post market surveillance via a web interface and data logging to complement the standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the quality of the pressure curves and the reactivity of the trigger, delivering a global performance which will be applicable to ventilator needs beyond theCOVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with their performance evaluation.
We propose the design of a ventilator which can be easily manufactured and integrated into the hospital environment to support COVID-19 patients. The unit is designed to support standard ventilator modes of operation, most importantly PRVC (Pressure Regulated Volume Control) and SIMV-PC (Synchronised Intermittent Mandatory Ventilation) modes. The unit is not yet an approved medical device and is in the concept and prototyping stage. It is presented here to invite fast feedback for development and deployment in the face of the COVID-19 pandemic.