ترغب بنشر مسار تعليمي؟ اضغط هنا

Design and Operation of a Windowless Gas Target Internal to a Solenoidal Magnet for Use with a Megawatt Electron Beam

70   0   0.0 ( 0 )
 نشر من قبل Sangbaek Lee
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A windowless hydrogen gas target of nominal thickness $10^{19}$ cm$^{-2}$ is an essential component of the DarkLight experiment, which is designed to utilize the megawatt electron beam at an Energy Recovery Linac (ERL). The design of such a target is challenging because the pressure drops by many orders of magnitude between the central, high-density section of the target and the surrounding beamline, resulting in laminar, transitional, and finally molecular flow regimes. The target system was assembled and operated at Jefferson Labs Low Energy Recirculator Facility (LERF) in 2016, and subsequently underwent several revisions and calibration tests at MIT Bates in 2017. The system at dynamic equilibrium was simulated in COMSOL to provide a better understanding of its optimal operation at other working points. We have determined that a windowless gas target with sufficiently high density for DarkLights experimental needs is feasible in an ERL environment.

قيم البحث

اقرأ أيضاً

A cryogenic supersonic gas jet target was developed for the MAGIX experiment at the high-intensity electron accelerator MESA. It will be operated as an internal, windowless target in the energy-recovering recirculation arc of the accelerator with dif ferent target gases, e.g., hydrogen, deuterium, helium, oxygen, argon, or xenon. Detailed studies have been carried out at the existing A1 multi-spectrometer facility at the electron accelerator MAMI. This paper focuses on the developed handling procedures and diagnostic tools, and on the performance of the gas jet target under beam conditions. Considering the special features of this type of target, it proves to be well suited for a new generation of high-precision electron scattering experiments at high-intensity electron accelerators.
162 - J. Pierce , J. Brock , C. Carlin 2021
We report on a windowless, high-density, gas flow target at Jefferson Lab that was used to measure $r_p$, the root-mean-square charge radius of the proton. To our knowledge, this is the first such system used in a fixed-target experiment at a (non-st orage ring) electron accelerator. The target achieved its design goal of an areal density of 2$times$10$^{18}$ atoms/cm$^2$, with the gas uniformly distributed over the 4 cm length of the cell and less than 1% residual gas outside the cell. This design eliminated scattering from the end caps of the target cell, a problem endemic to previous measurements of the proton charge radius in electron scattering experiments, and permitted a precise, model-independent extraction of $r_p$ by reaching unprecedentedly low values of $Q^2$, the square of the electrons transfer of four-momentum to the proton.
The design and operation of apparatus for measurements of in-beam hyperfine interactions and nuclear excited-state $g$ factors is described. This apparatus enables a magnetic field of about 0.1 tesla to be applied to the target and the target tempera ture to be set between $sim 4$ K and room temperature. Design concepts are developed mainly in terms of transient-field $g$-factor measurements following Coulomb excitation by the implantation perturbed angular correlation (IMPAC) technique. The formalism for perturbed angular correlations is outlined and a figure of merit for optimizing these measurements is derived to inform design. Particle detection is based on the use of silicon photodiodes of rectangular shape. The particle-$gamma$ angular correlation formalism for this case is described. The experimental program to date includes temperature-dependent studies of hyperfine fields, transient-field $g$-factor measurements, and time-dependent perturbed angular distribution (TDPAD) studies.
The central detector in the MuSun experiment is a pad-plane time projection ionization chamber that operates without gas amplification in deuterium at 31 K; it is used to measure the rate of the muon capture process $mu^- + d rightarrow n + n + u_mu $. A new charge-sensitive preamplifier, operated at 140 K, has been developed for this detector. It achieved a resolution of 4.5 keV(D$_2$) or 120 $e^-$ RMS with zero detector capacitance at 1.1 $mu$s integration time in laboratory tests. In the experimental environment, the electronic resolution is 10 keV(D$_2$) or 250 $e^-$ RMS at a 0.5 $mu$s integration time. The excellent energy resolution of this amplifier has enabled discrimination between signals from muon-catalyzed fusion and muon capture on chemical impurities, which will precisely determine systematic corrections due to these processes. It is also expected to improve the muon tracking and determination of the stopping location.
We present a conceptual design for a polarized $^3$He target for Jefferson Labs CLAS12 spectrometer in its standard configuration. This two-cell target will take advantage of advancements in optical pumping techniques at high magnetic field to create 60% longitudinally polarized $^3$He gas in a pumping cell inside the CLAS12 5 T solenoid. By transferring this gas to a 20 cm long, 5 K target cell, a target thickness of $3 times 10^{21}$ $^3$He/cm$^2$ will be produced, reaching the detectors specified maximum luminosity with a beam current of 2.5 $mu A$.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا