ترغب بنشر مسار تعليمي؟ اضغط هنا

Broadband Dual Frequency Comb Spectroscopy in a Rapid Compression Machine

117   0   0.0 ( 0 )
 نشر من قبل Nazanin Hoghooghi
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We demonstrate fiber mode-locked dual frequency comb spectroscopy for broadband, high resolution measurements in a rapid compression machine (RCM). We apply an apodization technique to improve the short-term signal-to-noise-ratio (SNR), which enables broadband spectroscopy at combustion-relevant timescales. We measure the absorption on 24345 individual wavelength elements (comb teeth) between 5967 and 6133 cm-1 at 704 microsecond time resolution during a 12-ms compression of a CH4-N2 mixture. We discuss the effect of the apodization technique on the absorption spectra, and apply an identical effect to the spectral model during fitting to recover the mixture temperature. The fitted temperature is compared against an adiabatic model, and found to be in good agreement with expected trends. This work demonstrates the potential of DCS to be used as an in situ diagnostic tool for broadband, high resolution, measurements in engine-like environments.



قيم البحث

اقرأ أيضاً

We present a chip-scale scanning dual-comb spectroscopy (SDCS) approach for broadband ultrahigh-resolution spectral acquisition. SDCS uses Si3N4 microring resonators that generate two single soliton micro-combs spanning 37 THz (300 nm) on the same ch ip from a single 1550-nm laser, forming a high-mutual-coherence dual-comb. We realize continuous tuning of the dual-comb system over the entire optical span of 37.5 THz with high precision using integrated microheater-based wavelength trackers. This continuous wavelength tuning is enabled by simultaneous tuning of the laser frequency and the two single soliton micro-combs over a full free spectral range of the microrings. We measure the SDCS resolution to be 319+-4.6 kHz. Using this SDCS system, we perform the molecular absorption spectroscopy of H13C14N over its 2.3 THz (18 nm)-wide overtone band, and show that the massively parallel heterodyning offered by the dual-comb expands the effective spectroscopic tuning speed of the laser by one order of magnitude. Our chip-scale SDCS opens the door to broadband spectrometry and massively parallel sensing with ultrahigh spectral resolution.
Dissipative Kerr-microresonator soliton combs (hereafter called soliton combs) are promising to realize chip scale integration of full soliton comb systems providing high precision, broad spectral coverage and a coherent link to the micro/mm/THz doma in with diverse applications coming on line all the time. However, the large soliton comb spacing hampers some applications. For example, for spectroscopic applications, there are simply not enough comb lines available to sufficiently cover almost any relevant absorption features. Here, we overcome this limitation by scanning the comb mode spacing by employing PDH locking and a microheater on the microresonator, showing continuous scanning of the soliton comb modes across nearly the full FSR of the microresonator without losing soliton operation, while spectral features with a bandwidth of as small of 5 MHz are resolved. Thus, comb mode scanning allows to cover the whole comb mode spectrum of tens of THz bandwidth with only one chip-scale comb.
In the current study, a quantum-cascade-laser-based dual-comb spectrometer (DCS) was used to paint a detailed picture of a 1.0 ms high-temperature reaction between propyne and oxygen. The DCS interfaced with a shock tube to provide pre-ignition condi tions of 1225 K, 2.8 atm, and 2% p-C3H4/18% O2/Ar. The spectrometer consisted of two free-running, non-stabilized frequency combs each emitting at 179 wavelengths between 1174 and 1233 cm-1. A free spectral range, f_r, of 9.86 GHz and a difference in comb spacing, {Delta}f_r, of 5 MHz, enabled a theoretical time resolution of 0.2 us but the data was time-integrated to 4 us to improve SNR. The accuracy of the spectrometer was monitored using a suite of independent laser diagnostics and good agreement observed.
Direct frequency comb spectroscopy of trapped ions is demonstated for the first time. It is shown that the 4s^2S_(1/2)-4p^2P_(3/2) transition in calcium ions can be excited directly with a frequency comb laser that is upconverted to 393 nm. Detection of the transition is performed using a shelving scheme to suppress background signal from non-resonant comb modes. The measured transition frequency of f=761 905 012.7(0.5) MHz presents an improvement in accuracy of more than two orders of magnitude.
Spectroscopy in the molecular fingerprint spectral region (6.5-20 $mu$m) yields critical information on material structure for physical, chemical and biological sciences. Despite decades of interest and effort, this portion of the electromagnetic spe ctrum remains challenging to cover with conventional laser technologies. In this report, we present a simple and robust method for generating super-octave, optical frequency combs in the fingerprint region through intra-pulse difference frequency generation in an orientation-patterned gallium phosphide crystal. We demonstrate the utility of this unique coherent light source for high-precision, dual-comb spectroscopy in methanol and ethanol vapor. These results highlight the potential of laser frequency combs for a wide range of molecular sensing applications, from basic molecular spectroscopy to nanoscopic imaging.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا