ترغب بنشر مسار تعليمي؟ اضغط هنا

Angular Sizes and Effective Temperatures of O-type Stars from Optical Interferometry with the CHARA Array

67   0   0.0 ( 0 )
 نشر من قبل Kathryn Gordon
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present interferometric observations of six O-type stars that were made with the Precision Astronomical Visible Observations (PAVO) beam combiner at the Center for High Angular Resolution Astronomy (CHARA) Array. The observations include multiple brackets for three targets, $lambda$~Ori~A, $zeta$~Oph, and 10~Lac, but there are only preliminary, single observations of the other three stars, $xi$~Per, $alpha$~Cam, and $zeta$~Ori~A. The stellar angular diameters range from 0.55 milliarcsec for $zeta$~Ori~A down to 0.11 mas for 10~Lac, the smallest star yet resolved with the CHARA Array. The rotational oblateness of the rapidly rotating star $zeta$ Oph is directly measured for the first time. We assembled ultraviolet to infrared flux measurements for these stars, and then derived angular diameters and reddening estimates using model atmospheres and an effective temperature set by published results from analysis of the line spectrum. The model-based angular diameters are in good agreement with observed angular diameters. We also present estimates for the effective temperatures of these stars derived by setting the interferometric angular size and fitting the spectrophotometry.

قيم البحث

اقرأ أيضاً

Using Georgia State Universitys CHARA Array interferometer, we measured angular diameters for 25 giant stars, six of which host exoplanets. The combination of these measurements and Hipparcos parallaxes produce physical linear radii for the sample. E xcept for two outliers, our values match angular diameters and physical radii estimated using photometric methods to within the associated errors with the advantage that our uncertainties are significantly lower. We also calculated the effective temperatures for the stars using the newly-measured diameters. Our values do not match those derived from spectroscopic observations as well, perhaps due to the inherent properties of the methods used or because of a missing source of extinction in the stellar models that would affect the spectroscopic temperatures.
66 - I. Karovicova 2018
Large stellar surveys of the Milky Way require validation with reference to a set of benchmark stars whose fundamental properties are well-determined. For metal-poor benchmark stars, disagreement between spectroscopic and interferometric effective te mperatures has called the reliability of the temperature scale into question. We present new interferometric measurements of three metal-poor benchmark stars, HD 140283, HD 122563, and HD 103095, from which we determine their effective temperatures. The angular sizes of all the stars were determined from observations with the PAVO beam combiner at visible wavelengths at the CHARA array, with additional observations of HD 103095 made with the VEGA instrument, also at the CHARA array. Together with photometrically derived bolometric fluxes, the angular diameters give a direct measurement of the effective temperature. For HD 140283 we find {theta}_LD = 0.324+/-0.005 mas, Teff = 5787+/-48 K; for HD 122563, {theta}_LD = 0.926+/-0.011 mas, Teff = 4636+/-37 K; and for HD 103095 {theta}_LD = 0.595+/-0.007 mas, Teff = 5140+/-49 K. Our temperatures for HD 140283 and HD 103095 are hotter than the previous interferometric measurements by 253 K and 322 K, respectively. We find good agreement between our temperatures and recent spectroscopic and photometric estimates. We conclude some previous interferometric measurements have been affected by systematic uncertainties larger than their quoted errors.
We present results of a long-baseline interferometry campaign using the PAVO beam combiner at the CHARA Array to measure the angular sizes of five main-sequence stars, one subgiant and four red giant stars for which solar-like oscillations have been detected by either Kepler or CoRoT. By combining interferometric angular diameters, Hipparcos parallaxes, asteroseismic densities, bolometric fluxes and high-resolution spectroscopy we derive a full set of near model-independent fundamental properties for the sample. We first use these properties to test asteroseismic scaling relations for the frequency of maximum power (nu_max) and the large frequency separation (Delta_nu). We find excellent agreement within the observational uncertainties, and empirically show that simple estimates of asteroseismic radii for main-sequence stars are accurate to <~4%. We furthermore find good agreement of our measured effective temperatures with spectroscopic and photometric estimates with mean deviations for stars between T_eff = 4600-6200 K of -22+/-32 K (with a scatter of 97K) and -58+/-31 K (with a scatter of 93 K), respectively. Finally we present a first comparison with evolutionary models, and find differences between observed and theoretical properties for the metal-rich main-sequence star HD173701. We conclude that the constraints presented in this study will have strong potential for testing stellar model physics, in particular when combined with detailed modelling of individual oscillation frequencies.
We measured the angular diameter of the lithium-rich K giant star HD 148293 using Georgia State Universitys Center for High Angular Resolution Astronomy (CHARA) Array interferometer. We used our measurement to calculate the stars effective temperatur e, which allowed us to place it on an H-R diagram to compare it with other Li-rich giants. Its placement supports the evidence presented by Charbonnel & Balachandran that it is undergoing a brief stage in its evolution where Li is being created.
Stellar models applied to large stellar surveys of the Milky Way need to be properly tested against a sample of stars with highly reliable fundamental stellar parameters. We have established a program aiming to deliver such a sample. We present new f undamental stellar parameters of nine dwarfs that will be used as benchmarks for large stellar surveys. One of these stars is the solar-twin 18Sco, which is one of the Gaia-ESO benchmarks. The goal is to reach a precision of 1% in Teff. This precision is important for accurate determinations of the full set of fundamental parameters and abundances of stars observed by the surveys. We observed HD131156 (xiBoo), HD146233 (18Sco), HD152391, HD173701, HD185395 (thetaCyg), HD186408 (16CygA), HD186427 (16CygB), HD190360 and HD207978 (15Peg) using the high angular resolution optical interferometric instrument PAVO/CHARA. We derived limb-darkening corrections from 3D model atmospheres and determined Teff directly from the Stefan-Boltzmann relation, with an iterative procedure to interpolate over tables of bolometric corrections. Surface gravities were estimated from comparisons to Dartmouth stellar evolution model tracks. We collected spectroscopic observations from the ELODIE spectrograph and estimated metallicities ([Fe/H]) from a 1D non-local thermodynamic equilibrium (NLTE) abundance analyses of unblended lines of neutral and singly ionized iron. For eight of the nine stars, we measure the Teff less than 1%, and for one star better than 2%. We determined the median uncertainties in logg and Fe/H as 0.015dex and 0.05dex, respectively. This study presents updated fundamental stellar parameters of nine dwarfs that can be used as a new set of benchmarks. All parameters were based on consistently combining interferometric observations, 3D limb-darkening modelling and spectroscopic analysis. The next paper will extend our sample to metal-rich giants.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا