ﻻ يوجد ملخص باللغة العربية
Introduction: Topical intranasal drugs are widely prescribed for Chronic Rhinosinusitis (CRS), although delivery can vary with device type and droplet size. The study objective was to compare nebulized and sprayed droplet deposition in the paranasal sinuses and ostiomeatal complex (OMC) across multiple droplet sizes in CRS patients using computational fluid dynamics (CFD). Methods: Three-dimensional models of sinonasal cavities were constructed from computed tomography (CT) scans of three subjects with CRS refractory to medical therapy using imaging software. Assuming steady-state inspiratory airflow at resting rate, CFD was used to simulate 1-120 {mu}m sprayed droplet deposition in the left and right sinuses and OMC with spray nozzle positioning as in current nasal spray use instructions. Zero-velocity nebulization simulations were performed for 1-30 {mu}m droplet sizes, maximal sinus and OMC deposition fractions (MSDF) were obtained, and sizes that achieved at least 50% of MSDF were identified. Nebulized MSDF was compared to sprayed droplet deposition. We also validated CFD framework through in vitro experiments. Results: Among nebulized droplet sizes, 11-14 {mu}m droplets achieved at least 50% of MSDF in all six sinonasal cavities. Five of six sinonasal cavities had greater sinus and OMC deposition with nebulized droplets than with sprayed droplets at optimal sizes. Conclusions: Nebulized droplets may target the sinuses and OMC more effectively than sprayed particles at sizes achieving best deposition. Further studies are needed to confirm our preliminary findings. Several commercial nasal nebulizers have average particle sizes outside the optimal nebulized droplet size range found here, suggesting potential for product enhancement.
Objective: Minimal literature exists investigating changes in inflammation with respect to the main nasal cavity (MNC) and paranasal sinuses (PS) before and after maximal medical therapy (MMT) for chronic rhinosinusitis (CRS). We hypothesized that MM
A patient-specific fluid-structure interaction (FSI) model of a phase-contrast magnetic resonance angiography (PC-MRA) imaged arteriovenous fistula is presented. The numerical model is developed and simulated using a commercial multiphysics simulatio
Objective: A numerical 3D model of the human trunk was developed to study the biomechanical effects of lumbar belts used to treat low back pain. Methods: This model was taken from trunk radiographies of a person and simplified so as to make a paramet
We study the energy deposition by light and heavy nuclei in tissue-like media as used for cancer therapy. The depth-dose distributions for protons, $^{3}$He, $^{12}$C, $^{20}$Ne, and $^{58}$Ni nuclei are calculated within a Monte Carlo model based on
Purpose: To develop an automated machine-learning-based method for the discovery of rapid and quantitative chemical exchange saturation transfer (CEST) MR fingerprinting acquisition and reconstruction protocols. Methods: An MR physics governed AI s