Characterization and Performance of PADMEs Cherenkov-Based Small-Angle Calorimeter

96   0   0.0 ( 0 )
 نشر من قبل Andre Frankenthal
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in Italy, will search for invisible decays of the hypothetical dark photon via the process $e^+e^-rightarrow gamma A$, where the $A$ escapes detection. The dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We report here on measurement and simulation studies of the performance of the Small-Angle Calorimeter, a component of PADMEs detector dedicated to rejecting 2- and 3-gamma backgrounds. The crucial requirement is a timing resolution of less than 200 ps, which is satisfied by the choice of PbF$_2$ crystals and the newly released Hamamatsu R13478UV photomultiplier tubes (PMTs). We find a timing resolution of 81 ps (with double-peak separation resolution of 1.8 ns) and a single-crystal energy resolution of 5.7%/$sqrt{E}$ with light yield of 2.07 photo-electrons per MeV, using 100 to 400 MeV electrons at the Beam Test Facility of LNF. We also propose the investigation of a two-PMT solution coupled to a single PbF$_2$ crystal for higher-energy applications, which has potentially attractive features.



قيم البحث

اقرأ أيضاً

110 - J. Caravaca , B. J. Land , M. Yeh 2020
This paper presents measurements of the scintillation light yield and time profile for a number of concentration of water-based liquid scintillator, formulated from linear alkylbenzene (LAB) and 2,5-diphenyloxazole (PPO). We find that the scintillati on light yield is linear with the concentration of liquid scintillator in water between 1 and 10% with a slope of 127.9+-17.0 ph/MeV/concentration and an intercept value of 108.3+-51.0 ph/MeV, the latter being illustrative of non-linearities with concentration at values less than 1%. This is larger than expected from a simple extrapolation of the pure liquid scintillator light yield. The measured time profiles are consistently faster than that of pure liquid scintillator, with rise times less than 250ps and prompt decay constants in the range of 2.1-2.85ns. Additionally, the separation between Cherenkov and scintillation light is quantified using cosmic muons in the CHESS experiment for each formulation, demonstrating an improvement in separation at the centimeter scale. Finally, we briefly discuss the prospects for large-scale detectors.
The PADME experiment at the LNF Beam Test Facility searches for dark photons produced in the annihilation of positrons with the electrons of a fix target. The strategy is to look for the reaction $e^{+}+e^{-}rightarrow gamma+A$, where $A$ is the dark photon, which cannot be observed directly or via its decay products. The electromagnetic calorimeter plays a key role in the experiment by measuring the energy and position of the final-state $gamma$. The missing four-momentum carried away by the $A$ can be evaluated from this information and the particle mass inferred. This paper presents the design, construction, and calibration of the PADMEs electromagnetic calorimeter. The results achieved in terms of equalisation, detection efficiency and energy resolution during the first phase of the experiment demonstrate the effectiveness of the various tools used to improve the calorimeter performance with respect to earlier prototypes.
The measurement of $BR(K^+topi^+ ubar{ u})$ with 10% precision by the NA62 experiment requires extreme background suppression. The Small Angle Calorimeter aims to provide an efficient veto for photons flying at angles down to zero with respect to the kaon flight direction. The initial prototype was upgraded and tested at the Beam Test Facility of the DA$Phi$NE Linac at Frascati. The energy resolution and the efficiency were measured and are presented.
The Cosmic Ray Energetics And Mass experiment for the International Space Station (ISS-CREAM) was installed on the ISS to measure high-energy cosmic-ray elemental spectra for the charge range $rm Z=1$ to 26. The ISS-CREAM instrument includes a tungst en scintillating-fiber calorimeter preceded by a carbon target for energy measurements. The carbon target induces hadronic interactions, and showers of secondary particles develop in the calorimeter. The energy deposition in the calorimeter is proportional to the particle energy. As a predecessor to ISS-CREAM, the balloon-borne CREAM instrument was successfully flown seven times over Antarctica for a cumulative exposure of 191 days. The CREAM calorimeter demonstrated its capability to measure energies of cosmic-ray particles, and the ISS-CREAM calorimeter is expected to have a similar performance. Before the launch, an engineering-unit calorimeter was shipped to CERN for calibration and performance tests. This beam test included position, energy, and angle scans of electron and pion beams together with a high-voltage scan for calibration and characterization. Additionally, an attenuation effect in the scintillating fibers was studied. In this paper, beam test results, including corrections for the attenuation effect, are presented.
We describe an algorithm which has been developed to extract fine granularity information from an electromagnetic calorimeter with strip-based readout. Such a calorimeter, based on scintillator strips, is being developed to apply particle flow recons truction to future experiments in high energy physics. Tests of this algorithm in full detector simulations, using strips of size 45 x 5 mm^2 show that the performance is close to that of a calorimeter with true 5 x 5 mm^2 readout granularity. The performance can be further improved by the use of 10 x 10 mm^2 tile- shaped layers interspersed between strip layers.