ترغب بنشر مسار تعليمي؟ اضغط هنا

Investigating the potentialities of Monte Carlo simulation for assessing soil water content via proximal gamma-ray spectroscopy

83   0   0.0 ( 0 )
 نشر من قبل Virginia Strati Dr
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Proximal gamma-ray spectroscopy recently emerged as a promising technique for non-stop monitoring of soil water content with possible applications in the field of precision farming. The potentialities of the method are investigated by means of Monte Carlo simulations applied to the reconstruction of gamma-ray spectra collected by a NaI scintillation detector permanently installed at an agricultural experimental site. A two steps simulation strategy based on a geometrical translational invariance is developed. The strengths of this approach are the reduction of computational time with respect to a direct source-detector simulation, the reconstruction of $^{40}K$, $^{232}Th$ and $^{238}U$ fundamental spectra, the customization in relation to different experimental scenarios and the investigation of effects due to individual variables for sensitivity studies. The reliability of the simulation is effectively validated against an experimental measurement with known soil water content and radionuclides abundances. The relation between soil water content and gamma signal is theoretically derived and applied to a Monte Carlo synthetic calibration performed with the specific soil composition of the experimental site. Ready to use general formulae and simulated coefficients for the estimation of soil water content are also provided adopting standard soil compositions. Linear regressions between input and output soil water contents, inferred from simulated $^{40}K$ and $^{208}Tl$ gamma signals, provide excellent results demonstrating the capability of the proposed method in estimating soil water content with an average uncertainty <1%.

قيم البحث

اقرأ أيضاً

Proximal gamma-ray spectroscopy supported by adequate calibration and correction for growing biomass is an effective field scale technique for a continuous monitoring of top soil water content dynamics to be potentially employed as a decision support tool for automatic irrigation scheduling. This study demonstrates that this approach has the potential to be one of the best space-time trade-off methods, representing a joining link between punctual and satellite fields of view. The inverse proportionality between soil moisture and gamma signal is theoretically derived taking into account a non-constant correction due to the presence of growing vegetation beneath the detector position. The gamma signal attenuation due to biomass is modelled with a Monte Carlo-based approach in terms of an equivalent water layer which thickness varies in time as the crop evolves during its life-cycle. The reliability and effectiveness of this approach is proved through a 7 months continuous acquisition of terrestrial gamma radiation in a 0.4 ha tomato (Solanum lycopersicum) test field. We demonstrate that a permanent gamma station installed at an agricultural field can reliably probe the water content of the top soil only if systematic effects due to the biomass shielding are properly accounted for. Biomass corrected experimental values of soil water content inferred from radiometric measurements are compared with gravimetric data acquired under different soil moisture levels, resulting in an average percentage relative discrepancy of about 3% in bare soil condition and of 4% during the vegetated period. The temporal evolution of corrected soil water content values exhibits a dynamic range coherent with the soil hydraulic properties in terms of wilting point, field capacity and saturation.
Proximal soil sensors are taking hold in the understanding of soil hydrogeological processes involved in precision agriculture. In this context, permanently installed gamma ray spectroscopy stations represent one of the best space-time trade off meth ods at field scale. This study proved the feasibility and reliability of soil water content monitoring through a seven-month continuous acquisition of terrestrial gamma radiation in a tomato test field. By employing a 1 L sodium iodide detector placed at a height of 2.25 m, we investigated the gamma signal coming from an area having a ~25 m radius and from a depth of approximately 30 cm. Experimental values, inferred after a calibration measurement and corrected for the presence of biomass, were corroborated with gravimetric data acquired under different soil moisture conditions, giving an average absolute discrepancy of about 2%. A quantitative comparison was carried out with data simulated by AquaCrop, CRITeRIA, and IRRINET soil-crop system models. The different goodness of fit obtained in bare soil condition and during the vegetated period highlighted that CRITeRIA showed the best agreement with the experimental data over the entire data-taking period while, in presence of the tomato crop, IRRINET provided the best results.
The accuracy of Monte Carlo simulations in reproducing the scientific performance of space telescopes (e.g. angular resolution) is mandatory for a correct design of the mission. A brand-new Monte Carlo simulator of the Astrorivelatore Gamma ad Immagi ni LEggero (AGILE)/Gamma-Ray Imaging Detector (GRID) space telescope, AGILESim, is built using the customizable Bologna Geant4 Multi-Mission Simulator (BoGEMMS) architecture and the latest Geant4 library to reproduce the instrument performance of the AGILE/GRID instrument. The Monte Carlo simulation output is digitized in the BoGEMMS postprocessing pipeline, according to the instrument electronic read-out logic, then converted into the onboard data handling format, and finally analyzed by the standard mission on-ground reconstruction pipeline, including the Kalman filter, as a real observation in space. In this paper we focus on the scientific validation of AGILESim, performed by reproducing (i) the conversion efficiency of the tracker planes, (ii) the tracker charge readout distribution measured by the on-ground assembly, integration, and verification activity, and (iii) the point-spread function of in-flight observations of the Vela pulsar in the 100 MeV - 1 GeV energy range. We measure an in-flight angular resolution (FWHM) for Vela-like point sources of $2.0^{+0.2}_{-0.3}$ and $0.8^{+0.1}_{-0.1}$ degrees in the 100 - 300 and 300 - 1000 MeV energy bands, respectively. The successful cross-comparison of the simulation results with the AGILE on-ground and in-space performance validates the BoGEMMS framework for its application to future gamma-ray trackers (e.g. e-ASTROGAM and AMEGO).
90 - Ji Qiang 2020
Monte Carlo simulations are widely used in many areas including particle accelerators. In this lecture, after a short introduction and reviewing of some statistical backgrounds, we will discuss methods such as direct inversion, rejection method, and Markov chain Monte Carlo to sample a probability distribution function, and methods for variance reduction to evaluate numerical integrals using the Monte Carlo simulation. We will also briefly introduce the quasi-Monte Carlo sampling at the end of this lecture.
We present a detailed study of the energetics of water clusters (H$_2$O)$_n$ with $n le 6$, comparing diffusion Monte Carlo (DMC) and approximate density functional theory (DFT) with well converged coupled-cluster benchmarks. We use the many-body dec omposition of the total energy to classify the errors of DMC and DFT into 1-body, 2-body and beyond-2-body components. Using both equilibrium cluster configurations and thermal ensembles of configurations, we find DMC to be uniformly much more accurate than DFT, partly because some of the approximate functionals give poor 1-body distortion energies. Even when these are corrected, DFT remains considerably less accurate than DMC. When both 1- and 2-body errors of DFT are corrected, some functionals compete in accuracy with DMC; however, other functionals remain worse, showing that they suffer from significant beyond-2-body errors. Combining the evidence presented here with the recently demonstrated high accuracy of DMC for ice structures, we suggest how DMC can now be used to provide benchmarks for larger clusters and for bulk liquid water.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا