ترغب بنشر مسار تعليمي؟ اضغط هنا

Reliable Determination of Contact Angle from the Height and Volume of Sessile Drops

171   0   0.0 ( 0 )
 نشر من قبل Peter Behroozi
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Feredoon Behroozi




اسأل ChatGPT حول البحث

Contact angle is an important parameter in characterizing the wetting properties of fluids. The most common methods for measuring the contact angle is to measure it directly from the profile curve of a sessile drop, a method with certain inherent drawbacks. Here we describe an alternative method that uses the height and volume of a sessile drop as constraints to construct its profile by numerical integration of its two governing differential equations. The integration yields, self consistently, the average value of the contact angle along the entire contact line as well as the footprint radius of the drop and its crown radius of curvature. As a test case, the new method is used to obtain the contact angle of pure water on two different substrates, Teflon and Lucite. For each substrate, four drops ranging in volume from 10 {mu}l to 40 {mu}l are used. The computed contact angles are consistent across the four different drop sizes for each substrate and are in agreement with typical literature values.



قيم البحث

اقرأ أيضاً

167 - Jordan Sakakeeny , Yue Ling 2020
Oscillation of sessile drops is important to many applications. In the present study, the natural oscillation of a sessile drop on flat surfaces with free contact lines (FCL) is investigated through numerical and theoretical analysis. The FCL conditi on represents a limit of contact line mobility, i.e. the contact angle remains constant when the contact line moves. In the numerical simulation, the interfaces are captured by the volume-of-fluid method and the contact angle at the boundary is specified using the height-function method. The oscillation frequencies for sessile drops with FCL are mainly controlled by the contact angle and the Bond number and a parametric study is carried out to characterize their effects on the frequencies for the first and high-order modes. Particular attention is paid to the frequency of the first mode, since it is usually the dominant mode. An inviscid theoretical model for the first mode is developed. The model yields an explicit expression for the first-mode frequency as a function of the contact angle and the Bond number, with all parameters involved fully determined by the equilibrium drop theory and the simulation. The predicted frequencies for a wide range of contact angles agree very well with the simulation results for small Bond numbers. The frequencies for both the first and high-order modes decrease with the contact angle and increase with the Bond number. For the high-order modes, the frequencies for different modes generally scale with the Rayleigh frequencies. The scaling relation performs better for small Bond numbers and large contact angles. A simple model is proposed to predict the frequencies of high-order modes for large contact angles and a good agreement with the simulation results is observed.
Sessile drops of soft hydrogels were vibrated vertically by subjecting them to a mechanically induced Gaussian white noise. Power spectra of the surface fluctuation of the gel allowed identification of its resonant frequency that decreases with their mass, but increases with its shear modulus. The principal resonant frequencies of the spheroidal modes of the gel of shear moduli ranging from 55 Pa to 290 Pa were closest to the lowest Rayleigh mode of vibration of a drop of pure water. These observations coupled with the fact that the resonance frequency varies inversely as the square root of the mass in all cases suggest that they primarily correspond to the capillary (or a pseudo-capillary) mode of drop vibration. The contact angles of the gel drops also increase with the modulus of the gel. When the resonance frequencies are corrected for the wetting angles, and plotted against the fundamental frequency scale (gamma/mu)^0.5, all the data collapse nicely on a single plot provided that the latter is shifted by a shear modulus dependent factor (1+mu.L/gamma). A length scale L, independent of both the modulus and the mass of the drop emerges from such a fit.
248 - Hamza Chraibi 2009
We study numerically the deformation of sessile dielectric drops immersed in a second fluid when submitted to the optical radiation pressure of a continuous Gaussian laser wave. Both drop stretching and drop squeezing are investigated at steady state where capillary effects balance the optical radiation pressure. A boundary integral method is implemented to solve the axisymmetric Stokes flow in the two fluids. In the stretching case, we find that the drop shape goes from prolate to near-conical for increasing optical radiation pressure whatever the drop to beam radius ratio and the refractive index contrast between the two fluids. The semi-angle of the cone at equilibrium decreases with the drop to beam radius ratio and is weakly influenced by the index contrast. Above a threshold value of the radiation pressure, these optical cones become unstable and a disruption is observed. Conversely, when optically squeezed, the drop shifts from an oblate to a concave shape leading to the formation of a stable optical torus. These findings extend the electrohydrodynamics approach of drop deformation to the much less investigated optical domain and reveal the openings offered by laser waves to actively manipulate droplets at the micrometer scale.
When two sessile drops of the same liquid touch, they merge into one drop, driven by capillarity. However, the coalescence can be delayed, or even completely stalled for a substantial period of time, when the two drops have different surface tensions , despite being perfectly miscible. A temporary state of non-coalescence arises, during which the drops move on their substrate, only connected by a thin neck between them. Existing literature covers pure liquids and mixtures with low surface activities. In this paper, we focus on the case of large surface activities, using aqueous surfactant solutions with varying concentrations. It is shown that the coalescence behavior can be classified into three regimes that occur for different surface tensions and contact angles of the droplets at initial contact. However, not all phenomenology can be predicted from surface tension contrast or contact angles alone, but strongly depends on the surfactant concentrations as well. This reveals that the merging process is not solely governed by hydrodynamics and geometry, but also depends on the molecular physics of surface adsorption.
The internal dynamics during the coalescence of a sessile droplet and a subsequently deposited impacting droplet, with either identical or distinct surface tension, is studied experimentally in the regime where surface tension is dominant. Two color high-speed cameras are used to capture the rapid internal flows and associated mixing from both side and bottom views simultaneously by adding an inert dye to the impacting droplet. Given sufficient lateral separation between droplets of identical surface tension, a robust surface jet is identified on top of the coalesced droplet. Image processing shows this jet is the result of a surface flow caused by the impact inertia and an immobile contact line. By introducing surface tension differences between the coalescing droplets, the surface jet can be either enhanced or suppressed via a Marangoni flow. The influence of the initial droplet configuration and relative surface tension on the long-term dynamics and mixing efficiency, plus the implications for emerging applications such as reactive inkjet printing, are also considered.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا