ترغب بنشر مسار تعليمي؟ اضغط هنا

A Graphical Measure of Aggregate Flexibility for Energy-Constrained Distributed Resources

76   0   0.0 ( 0 )
 نشر من قبل Michael Evans
 تاريخ النشر 2018
  مجال البحث الهندسة المعلوماتية
والبحث باللغة English




اسأل ChatGPT حول البحث

We consider the problem of dispatching a fleet of heterogeneous energy storage units to provide grid support. Under the restriction that recharging is not possible during the time frame of interest, we develop an aggregate measure of fleet flexibility with an intuitive graphical interpretation. This analytical expression summarises the full set of demand traces that the fleet can satisfy, and can be used for immediate and straightforward determination of the feasibility of any service request. This representation therefore facilitates a wide range of capability assessments, such as flexibility comparisons between fleets or the determination of a fleets ability to deliver ancillary services. Examples are shown of applications to fleet flexibility comparisons, signal feasibility assessment and the optimisation of ancillary service provision.

قيم البحث

اقرأ أيضاً

We consider the problem of dispatching a fleet of distributed energy reserve devices to collectively meet a sequence of power requests over time. Under the restriction that reserves cannot be replenished, we aim to maximise the survival time of an en ergy-constrained islanded electrical system; and we discuss realistic scenarios in which this might be the ultimate goal of the grid operator. We present a policy that achieves this optimality, and generalise this into a set-theoretic result that implies there is no better policy available, regardless of the realised energy requirement scenario.
In this paper, we present a data-driven secondary controller for regulating to some desired values several variables of interest in a power system, namely, electrical frequency, voltage magnitudes at critical buses, and active power flows through cri tical lines. The power generation system is based on distributed energy resources (DERs) interfaced with either grid-forming (GFM) or grid-following (GFL) inverters. The secondary controller is based on online feedback optimization leveraging the learned sensitivities of the changes in the system frequency, voltage magnitudes at critical buses, and active power flows through critical lines to the changes in inverter active and reactive power setpoints. To learn the sensitivities accurately from data, the feedback optimization has a built-in mechanism for keeping the secondary control inputs persistently exciting without degrading its performance. The feedback optimization also utilizes the learned power-voltage characteristics of photovoltaic (PV) arrays to compute DC-link voltage setpoints so as to allow the PV arrays to track the power setpoints. To learn the power-voltage characteristics, we separately execute a data-driven approach that fits a concave polynomial to the collected power-voltage measurements by solving a sum-of-squares (SoS) optimization. We showcase the secondary controller using the modified IEEE-14 bus test system, in which conventional energy sources are replaced with inverter-interfaced DERs.
79 - Yishen Wang , Zhehan Yi , Di Shi 2018
As microgrids have advanced from early prototypes to relatively mature technologies, converting data center integrated commercial buildings to microgrids provides economic, reliability and resiliency enhancements for the building owners. Thus, microg rid design and economically sizing distributed energy resources (DER) are becoming more demanding to gain widespread microgrids commercial viability. In this paper, an optimal DER sizing formulation for a hybrid AC/DC microgrid configuration has been proposed to leverage all benefits that AC or DC microgrid could solely contribute. Energy storage (ES), photovoltaics (PV) and power electronics devices are coordinately sized for economic grid-connected and reliable islanded operations. Time-of-use (TOU) energy usages charges and peak demand charges are explicitly modeled to achieve maximum level of cost savings. Numerical results obtained from a real commercial building load demonstrate the benefits of the proposed approach and the importance of jointly sizing DER for the grid-connected and islanded modes.
Distributed energy resources (DERs) can serve as non-wire alternatives (NWAs) to capacity expansion by managing peak load to avoid or delay traditional expansion projects. However, the value stream derived from using DERs as NWAs is usually not expli citly included in DER planning problems. In this paper, we study a planning problem that co-optimizes investment and operation of DERs and the timing of capacity expansion. By including the timing of capacity expansion as a decision variable, we naturally incorporate NWA value stream of DERs into the planning problem. Furthermore, we show that even though the resulting optimization problem could have millions of variables and is non-convex, an optimal solution can be found by solving a series of smaller linear problems. Finally, we present a NWAs planning problem using real data from the Seattle Campus of the University of Washington.
142 - Yue Chen , Wei Wei , Mingxuan Li 2021
Flexible load at the demand-side has been regarded as an effective measure to cope with volatile distributed renewable generations. To unlock the demand-side flexibility, this paper proposes a peer-to-peer energy sharing mechanism that facilitates en ergy exchange among users while preserving privacy. We prove the existence and partial uniqueness of the energy sharing market equilibrium and provide a centralized optimization to obtain the equilibrium. The centralized optimization is further linearized by a convex combination approach, turning into a multi-parametric linear program (MP-LP) with renewable output deviations being the parameters. The flexibility requirement of individual users is calculated based on this MP-LP. To be specific, an adaptive vertex generation algorithm is established to construct a piecewise linear estimator of the optimal total cost subject to a given error tolerance. Critical regions and optimal strategies are retrieved from the obtained approximate cost function to evaluate the flexibility requirement. The proposed algorithm does not rely on the exact characterization of optimal basis invariant sets and thus is not influenced by model degeneracy, a common difficulty faced by existing approaches. Case studies validate the theoretical results and show that the proposed method is scalable.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا