ترغب بنشر مسار تعليمي؟ اضغط هنا

An ultra-compact low temperature scanning probe microscope for magnetic fields above 30 T

367   0   0.0 ( 0 )
 نشر من قبل Lisa Rossi
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present the design of a highly compact High Field Scanning Probe Microscope (HF-SPM) for operation at cryogenic temperatures in an extremely high magnetic field, provided by a water-cooled Bitter magnet able to reach 38 T. The HF-SPM is 14 mm in diameter: an Attocube nano-positioner controls the coarse approach of a piezo resistive AFM cantilever to a scanned sample. The Bitter magnet constitutes an extreme environment for SPM due to the high level of vibrational noise; the Bitter magnet noise at frequencies up to 300 kHz is characterized and noise mitigation methods are described. The performance of the HF-SPM is demonstrated by topographic imaging and noise measurements at up to 30 T. Additionally, the use of the SPM as a three-dimensional dilatometer for magnetostriction measurements is demonstrated via measurements on a magnetically frustrated spinel sample.

قيم البحث

اقرأ أيضاً

142 - T. Machida , Y. Kohsaka , 2018
We describe the development and performance of an ultra-high vacuum scanning tunneling microscope working under combined extreme conditions of ultra-low temperatures and high magnetic fields. We combined a top-loading dilution refrigerator and a stan dard bucket dewar with a bottom-loading superconducting magnet to achieve 4.5 days operating time, which is long enough to perform various spectroscopic-imaging measurements. To bring the effective electron temperature closer to the mixing-chamber temperature, we paid particular attention to filtering out the radio-frequency noise, as well as enhancing the thermal link between the microscope unit and the mixing chamber. We estimated the lowest effective electron temperature to be below 90 mK by measuring the superconducting-gap spectrum of aluminum. We confirmed the long-term stability of the spectroscopic-imaging measurement by visualizing superconducting vortices in the cuprate superconductor Bi$_{2}$Sr$_{2}$CaCu$_{2}$O$_{8+delta}$.
114 - W. Tao , S. Singh , L. Rossi 2017
We present the design and performance of a cryogenic scanning tunneling microscope (STM) which operates inside a water-cooled Bitter magnet, which can attain a magnetic field of up to 38 T. Due to the high vibration environment generated by the magne t cooling water, a uniquely designed STM and vibration damping system are required. The STM scan head is designed to be as compact and rigid as possible, to minimize the effect of vibrational noise as well as fit the size constraints of the Bitter magnet. The STM uses a differential screw mechanism for coarse tip - sample approach, and operates in helium exchange gas at cryogenic temperatures. The reliability and performance of the STM are demonstrated through topographic imaging and scanning tunneling spectroscopy (STS) on highly oriented pyrolytic graphite (HOPG) at T = 4.2 K and in magnetic fields up to 34 T.
We describe the design, construction, and performance of an ultra-high vacuum (UHV) scanning tunneling microscope (STM) capable of imaging at dilution-refrigerator temperatures and equipped with a vector magnet. The primary objective of our design is to achieve a high level of modularity by partitioning the STM system into a set of easily separable, interchangeable components. This naturally segregates the UHV needs of STM instrumentation from the typically non-UHV construction of a dilution refrigerator, facilitating the usage of non-UHV materials while maintaining a fully bakeable UHV chamber that houses the STM. The modular design also permits speedy removal of the microscope head from the rest of the system, allowing for repairs, modifications, and even replacement of the entire microscope head to be made at any time without warming the cryostat or compromising the vacuum. Without using cryogenic filters, we measured an electron temperature of 184 mK on a superconducting Al(100) single crystal.
A low-temperature ultra-high vacuum scanning probe microscopy (SPM) system with molecular beam epitaxy capability and optical access was conceived, built, and tested in our lab. The design of the whole system is discussed here, with special emphasis on some critical parts. We made an SPM scanner head with a modified Pan-type design, enclosed by a double-layer cold room under a bath type cryostat. The scanner head is very rigid, compatible with optical access paths, and can accommodate both scanning tunneling microscope (STM) tips and atomic force sensors. Two piezo-actuated focus-lens stages are mounted on the two sides of the cold room to couple light in and out. To demonstrate the system performance, we performed STM and scanning tunneling spectroscopy studies. The herringbone reconstruction and atomic structure of Au(111) surface were clearly resolved. The dI/dV spectra of an Au(111) surface were obtained at 5 K. In addition, a periodic 2D tellurium (Te) structure was grown on Au(111) surface using MBE.
We present a probe-type scanning tunneling microscope (STM) with atomic resolution that is designed to be directly inserted and work in a harsh vibrational cryogen-free superconducting magnet system. When a commercial variable temperature insert (VTI ) is installed in the magnet and the STM is in turn housed in the VTI, a lowest temperature of 1.6 K can be achieved, where the STM still operates well. We have tested it in an 8 T superconducting magnet cooled with the pulse-tube cryocooler (PTC) and obtained atomically revolved graphite and NiSe2 images as well as the scanning tunneling spectrum (STS, i.e. dI/dV spectrum) data of the latter near its critical temperature, which show the formation process of the superconducting gap as a function of temperature. The drifting rates of the STM at 1.6 K in X-Y plane and Z direction are 1.15 and 1.71 pm/min respectively. Noise analysis for the tunneling current shows that the amplitudes of the dominant peaks (6.84 and 10.25Hz) are low. This is important as a cryogen-free magnet system has long been considered too harsh for any atomic resolution measurement.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا