ترغب بنشر مسار تعليمي؟ اضغط هنا

Development of a 32-channel ASIC for an X-ray APD Detector onboard the ISS

76   0   0.0 ( 0 )
 نشر من قبل Makoto Arimoto
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space Station. To realize wide-band detection from 20 keV to 1 MeV, we use Ce:GAGG scintillators, each coupled to an APD, with low-noise front-end electronics capable of achieving a minimum energy detection threshold of 20 keV. The developed ASIC has the ability to read out 32-channel APD signals using 0.35 $mu$m CMOS technology, and an analog amplifier at the input stage is designed to suppress the capacitive noise primarily arising from the large detector capacitance of the APDs. The ASIC achieves a performance of 2099 e$^{-}$ + 1.5 e$^{-}$/pF at root mean square (RMS) with a wide 300 fC dynamic range. Coupling a reverse-type APD with a Ce:GAGG scintillator, we obtain an energy resolution of 6.7% (FWHM) at 662 keV and a minimum detectable energy of 20 keV at room temperature (20 $^{circ}$C). Furthermore, we examine the radiation tolerance for space applications by using a 90 MeV proton beam, confirming that the ASIC is free of single-event effects and can operate properly without serious degradation in analog and digital processing.



قيم البحث

اقرأ أيضاً

We report the radiation hardness of a p-channel CCD developed for the X-ray CCD camera onboard the XRISM satellite. This CCD has basically the same characteristics as the one used in the previous Hitomi satellite, but newly employs a notch structure of potential for signal charges by increasing the implant concentration in the channel. The new device was exposed up to approximately $7.9 times 10^{10} mathrm{~protons~cm^{-2}}$ at 100 MeV. The charge transfer inefficiency was estimated as a function of proton fluence with an ${}^{55} mathrm{Fe}$ source. A device without the notch structure was also examined for comparison. The result shows that the notch device has a significantly higher radiation hardness than those without the notch structure including the device adopted for Hitomi. This proves that the new CCD is radiation tolerant for space applications with a sufficient margin.
109 - Y. Asaoka , S. Ozawa , S. Torii 2018
The CALorimetric Electron Telescope (CALET), launched for installation on the International Space Station (ISS) in August, 2015, has been accumulating scientific data since October, 2015. CALET is intended to perform long-duration observations of hig h-energy cosmic rays onboard the ISS. CALET directly measures the cosmic-ray electron spectrum in the energy range of 1 GeV to 20 TeV with a 2% energy resolution above 30 GeV. In addition, the instrument can measure the spectrum of gamma rays well into the TeV range, and the spectra of protons and nuclei up to a PeV. In order to operate the CALET onboard ISS, JAXA Ground Support Equipment (JAXA-GSE) and the Waseda CALET Operations Center (WCOC) have been established. Scientific operations using CALET are planned at WCOC, taking into account orbital variations of geomagnetic rigidity cutoff. Scheduled command sequences are used to control the CALET observation modes on orbit. Calibration data acquisition by, for example, recording pedestal and penetrating particle events, a low-energy electron trigger mode operating at high geomagnetic latitude, a low-energy gamma-ray trigger mode operating at low geomagnetic latitude, and an ultra heavy trigger mode, are scheduled around the ISS orbit while maintaining maximum exposure to high-energy electrons and other high-energy shower events by always having the high-energy trigger mode active. The WCOC also prepares and distributes CALET flight data to collaborators in Italy and the United States. As of August 31, 2017, the total observation time is 689 days with a live time fraction of the total time of approximately 84%. Nearly 450 million events are collected with a high-energy (E>10 GeV) trigger. By combining all operation modes with the excellent-quality on-orbit data collected thus far, it is expected that a five-year observation period will provide a wealth of new and interesting results.
FORCE is a Japan-US space-based astronomy mission for an X-ray imaging spectroscopy in an energy range of 1--80 keV. The Wideband Hybrid X-ray Imager (WHXI), which is the main focal plane detector, will use a hybrid semiconductor imager stack compose d of silicon and cadmium telluride (CdTe). The silicon imager will be a certain type of the silicon-on-insulator (SOI) pixel sensor, named the X-ray pixel (XRPIX) series. Since the sensor has a small pixel size (30--36 $mu$m) and a thick sensitive region (300--500 $mu$m), understanding the detector response is not trivial and is important in order to optimize the camera design and to evaluate the scientific capabilities. We have developed a framework to simulate observations of celestial sources with semiconductor sensors. Our simulation framework was tested and validated by comparing our simulation results to laboratory measurements using the XRPIX 6H sensor. The simulator well reproduced the measurement results with reasonable physical parameters of the sensor including an electric field structure, a Coulomb repulsion effect on the carrier diffusion, and arrangement of the degraded regions. This framework is also applicable to future XRPIX updates including the one which will be part of the WHXI, as well as various types of semiconductor sensors.
We are developing a kilo-pixels Ti/Au TES array as a backup option for Athena X-IFU. Here we report on single-pixel performance of a 32$times$32 array operated in a Frequency Division Multiplexing (FDM) readout system, with bias frequencies in the ra nge 1-5 MHz. We have tested the pixels response at several photon energies, by means of a $^{55}$Fe radioactive source (emitting Mn-K$alpha$ at 5.9 keV) and a Modulated X-ray Source (MXS, providing Cr-K$alpha$ at 5.4 keV and Cu-K$alpha$ at 8.0 keV). First, we report the procedure used to perform the detector energy scale calibration, usually achieving a calibration accuracy better than $sim$ 0.5 eV in the 5.4 - 8.9 keV energy range. Then, we present the measured energy resolution at the different energies (best single pixel performance: $Delta$E$_{FWHM}$ = 2.40 $pm$ 0.09 eV @ 5.4 keV; 2.53 $pm$ 0.10 eV @ 5.9 keV; 2.78 $pm$ 0.16 eV @ 8.0 keV), investigating also the performance dependency from the pixel bias frequency and the count rate. Thanks to long background measurements ($sim$ 1 day), we finally detected also the Al-K$alpha$ line at 1.5 keV, generated by fluorescence inside the experimental setup. We analyzed this line to obtain a first assessment of the single-pixel performance also at low energy ($Delta$E$_{FWHM}$ = 1.91 eV $pm$ 0.21 eV @ 1.5 keV), and to evaluate the linearity of the detector response in a large energy band (1.5 - 8.9 keV).
Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $mathrm{Delta}E<$3 eV full-width-half-maximum (FWHM) in the soft X-ray e nergy range. We are currently developing X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led by ESA and foreseen to be launched in 2031. In this contribution, we report on the development and the characterization of a uniform 32$times$32 pixel array with (length$times $width) 140$times$30 $mu$m$^2$ TiAu TESs, which have textcolor{black}{a 2.3 $mu$m} thick Au absorber for X-ray photons. The pixels have a typical normal resistance $R_mathrm{n}$ = 121 m$Omega$ and a critical temperature $T_mathrm{c}sim$ 90 mK. We performed extensive measurements on 60 pixels out of the array in order to show the uniformity of the array. We obtained an energy resolutions between 2.4 and 2.6 eV (FWHM) at 5.9 keV, measured in a single-pixel mode at AC bias frequencies ranging from 1 to 5 MHz, with a frequency domain multiplexing (FDM) readout system, which is developed at SRON/VTT. We also present the detector energy resolution at X-ray with different photon energies generated by a modulated external X-ray source from 1.45 keV up to 8.9 keV. Multiplexing readout across several pixels has also been performed to evaluate the impact of the thermal crosstalk to the instruments energy resolution budget requirement. This value results in a derived requirement, for the first neighbour, that is less than 1$times$10$^{-3}$ when considering the ratio between the amplitude of the crosstalk signal to an X-ray pulse (for example at 5.9 keV)
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا