ترغب بنشر مسار تعليمي؟ اضغط هنا

Progress Report on an Ultra-compact LumiCal

42   0   0.0 ( 0 )
 نشر من قبل Oleksandr Borysov Dr
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Oleksandr Borysov




اسأل ChatGPT حول البحث

A new design of a detector module of submillimeter thickness for an electromagnetic calorimeter is presented. It is aimed to be used in the luminometers LumiCal and BeamCal in future linear e$^{+}$e$^{-}$ collider experiments. The module prototypes were produced utilizing novel connectivity schemes technologies. They are installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of 1 GeV $-$ 6 GeV. The performance of eight detector modules and the possibility of electron and photon identification is studied.

قيم البحث

اقرأ أيضاً

MOSARIX is a collaborative project between three research group in Sorbonne University to build a x-ray spectrometer (2-5 keV) portable to large scale facilities with high efficiency and good resolution. X-ray spectroscopy and coincidences experiment are planned. A prototype with a single HADP crystal with von Hamos geometry has been tested (resolution and efficiency). A fast time and position detector has been realized (patent and publication).We plan to build the spectrometer with 8 HADP (or 4) crystals under Helium atmosphere using a TimePix3 or a CCD camera. MOSARIX is a project of an x-ray spectrometer in the tender x-ray domain (2-5 keV) with high efficiency, allowing performing x-ray emission and coincidences (or covariance mapping) experiments using synchrotron radiation, XFEL, the future installation SPIRAL2/GANIL or CRYRING/FAIR. It involves 2 groups at LCPMR (Francis PENENT and Marc SIMON) and one group at INSP (Dominique VERNHET). The coincidences/covariance measurements will be between x-ray photons and ions or electrons. It would be the first time for such coincidences with energy-resolved photons. The spectrometer will be portable and will be brought to the different large-scale facilities. MOSARIX is a multi-crystal HAPG von Hamos spectrometer optimized for the 2-5 keV photon energy range. Its resolving power E/DE will be 4000. It will be equipped with a fast time and position sensitive detection system, allowing performing coincidences, or with a CCD camera. I. Scientific case and some possible experiments The accelerated development of x-ray sources, as 3 rd generation synchrotrons (and recent upgrades) or free-electron lasers, has opened new opportunities to investigate new phenomena by means of photoelectron and Auger spectroscopy, electron-ion coincidence techniques and x-ray emission. However, several processes of high scientific interests are still hard to measure; some of them require the measurement of photons with high efficiency, high resolution and even sometimes in coincidence mode. This is the purpose of MOSARIX development. As an example, we propose to revisit Resonance-Enhanced X-ray Multiple Ionization (REXMI) 1 with a significant amelioration of the detection of photons, i.e. measuring the photons not only with high efficiency and high resolution but also in coincidence with ions or electrons. This will allow accessing the involved intermediate states and obtaining a clearer image of the dynamic of the multiple ionization process. MOSARIX can also be used for the investigation of very low cross-section phenomena such as attosecond electron dynamics 2 and High-Energy Resolution Off-Resonant Spectroscopy (HEROS) 3,4. X-ray spectroscopy has also proved to be a very powerful tool to investigate quantum dynamics in heavy ions collisions with matter of whatever nature, dilute or condensed 5-7. A
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector plan es were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1-5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Moli`ere radius at 5 GeV was determined to be (8.1 +/- 0.1 (stat) +/- 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 +/- 0.1) mm. The dependence of the effective Moli`ere radius on the electron energy in the range 1-5 GeV was also studied. Good agreement was obtained between data and MC simulation.
184 - Maryna Borysova 2021
The FCAL collaboration is preparing large-scale prototypes of special calorimeters to be used in the very forward region at future electron-positron colliders for a precise measurement of integrated luminosity and for instant luminosity measurement a nd assisting beam-tuning. LumiCal is designed as a silicon-tungsten sandwich calorimeter with very thin sensor planes to keep the Moli`ere radius small, facilitating such the measurement of electron showers in the presence of background. Dedicated front-end electronics has been developed to match the timing and dynamic range requirements. A partially instrumented prototype was investigated in a 1 to 5 GeV electron beam at the DESY II synchrotron. In the recent beam tests, a multi-plane compact prototype was equipped with thin detector planes fully assembled with readout electronics and installed in 1 mm gaps between tungsten plates of one radiation length thickness. High statistics data were used to perform sensor alignment, and to measure the longitudinal and transversal shower development in the sandwich. This talk covers the latest status of the calorimeter prototype development and selected performance results, obtained in test beam measurements, the prospects for the upcoming DESY test beam, as well as the expected simulation performance.
We report the successful commissioning and testing of a dedicated field-ioniser chamber for measuring principal quantum number distributions in antihydrogen as part of the ASACUSA hyperfine spectroscopy apparatus. The new chamber is combined with a b eam normalisation detector that consists of plastic scintillators and a retractable passivated implanted planar silicon (PIPS) detector.
109 - Oleksandr Borysov 2017
LumiCal is a sampling electromagnetic calorimeter designed for the precise measurement of integrated luminosity in electron positron linear collider experiments. The present report contains a description and results of the first beam test of a multil ayer LumiCal prototype with four silicon detector planes. A 5 GeV electron beam from the CERN PS T9 facility was used to study the performance of the LumiCal prototype. Presented results are mainly focused on the transverse structure of the observed electromagnetic shower and the Moli`ere radius measurement. A comparison with MC simulation is also discussed.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا