ترغب بنشر مسار تعليمي؟ اضغط هنا

Charge-induced force-noise on free-falling test masses: results from LISA Pathfinder

313   0   0.0 ( 0 )
 نشر من قبل Peter Wass
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We report on electrostatic measurements made on board the European Space Agency mission LISA Pathfinder. Detailed measurements of the charge-induced electrostatic forces exerted on free-falling test masses (TMs) inside the capacitive gravitational reference sensor are the first made in a relevant environment for a space-based gravitational wave detector. Employing a combination of charge control and electric-field compensation, we show that the level of charge-induced acceleration noise on a single TM can be maintained at a level close to 1.0 fm/s^2/sqrt(Hz) across the 0.1-100 mHz frequency band that is crucial to an observatory such as LISA. Using dedicated measurements that detect these effects in the differential acceleration between the two test masses, we resolve the stochastic nature of the TM charge build up due to interplanetary cosmic rays and the TM charge-to-force coupling through stray electric fields in the sensor. All our measurements are in good agreement with predictions based on a relatively simple electrostatic model of the LISA Pathfinder instrument.



قيم البحث

اقرأ أيضاً

134 - M. Armano , H. Audley , J. Baird 2018
The LISA Pathfinder charge management device was responsible for neutralising the cosmic ray induced electric charge that inevitably accumulated on the free-falling test masses at the heart of the experiment. We present measurements made on ground an d in-flight that quantify the performance of this contactless discharge system which was based on photo-emission under UV illumination. In addition, a two-part simulation is described that was developed alongside the hardware. Modelling of the absorbed UV light within the Pathfinder sensor was carried out with the GEANT4 software toolkit and a separate MATLAB charge transfer model calculated the net photocurrent between the test masses and surrounding housing in the presence of AC and DC electric fields. We confront the results of these models with observations and draw conclusions for the design of discharge systems for future experiments like LISA that will also employ free-falling test masses.
During the On-Station Thermal Test campaign of the LISA Pathfinder the data and diagnostics subsystem was tested in nearly space conditions for the first time after integration in the satellite. The results showed the compliance of the temperature me asurement system, obtaining temperature noise around $10^{-4},{rm K}, {rm Hz}^{-1/2}$ in the frequency band of $1-30;{rm mHz}$. In addition, controlled injection of heat signals to the suspension struts anchoring the LISA Technology Package (LTP) Core Assembly to the satellite structure allowed to experimentally estimate for the first time the phase noise contribution through thermo-elastic distortion of the LTP interferometer, the satellites main instrument. Such contribution was found to be at $10^{-12},{rm m}, {rm Hz}^{-1/2}$, a factor of 30 below the measured noise at the lower end of the measurement bandwidth ($1,{rm mHz}$).
The LTP (LISA Testflight Package), to be flown aboard the ESA / NASA LISA Pathfinder mission, aims to demonstrate drag-free control for LISA test masses with acceleration noise below 30 fm/s^2/Hz^1/2 from 1-30 mHz. This paper describes the LTP measur ement of random, position independent forces acting on the test masses. In addition to putting an overall upper limit for all source of random force noise, LTP will measure the conversion of several key disturbances into acceleration noise and thus allow a more detailed characterization of the drag-free performance to be expected for LISA.
Since the 2017 Nobel Prize in Physics was awarded for the observation of gravitational waves, it is fair to say that the epoch of gravitational wave astronomy (GWs) has begun. However, a number of interesting sources of GWs can only be observed from space. To demonstrate the feasibility of the Laser Interferometer Space Antenna (LISA), a future gravitational wave observatory in space, the LISA Pathfinder satellite was launched on December, 3rd 2015. Measurements of the spurious forces accelerating an otherwise free-falling test mass, and detailed investigations of the individual subsystems needed to achieve the free-fall, have been conducted throughout the mission. This overview article starts with the purpose and aim of the mission, explains satellite hardware and mission operations and ends with a summary of selected important results and an outlook towards LISA. From the LISA Pathfinder experience, we can conclude that the proposed LISA mission is feasible.
The science operations of the LISA Pathfinder mission has demonstrated the feasibility of sub-femto-g free-fall of macroscopic test masses necessary to build a LISA-like gravitational wave observatory in space. While the main focus of interest, i.e. the optical axis or the $x$-axis, has been extensively studied, it is also of interest to evaluate the stability of the spacecraft with respect to all the other degrees of freedom. The current paper is dedicated to such a study, with a focus set on an exhaustive and quantitative evaluation of the imperfections and dynamical effects that impact the stability with respect to its local geodesic. A model of the complete closed-loop system provides a comprehensive understanding of each part of the in-loop coordinates spectra. As will be presented, this model gives very good agreements with LISA Pathfinder flight data. It allows one to identify the physical noise source at the origin and the physical phenomena underlying the couplings. From this, the performances of the stability of the spacecraft, with respect to its geodesic, are extracted as a function of frequency. Close to $1 mHz$, the stability of the spacecraft on the $X_{SC}$, $Y_{SC}$ and $Z_{SC}$ degrees of freedom is shown to be of the order of $5.0 10^{-15} m s^{-2}/sqrt{Hz}$ for X and $4.0 10^{-14} m s^{-2}/sqrt{Hz}$ for Y and Z. For the angular degrees of freedom, the values are of the order $3 10^{-12} rad s^{-2}/sqrt{Hz}$ for $Theta_{SC}$ and $3 10^{-13} rad s^{-2}/sqrt{Hz}$ for $H_{SC}$ and $Phi_{SC}$.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا