ترغب بنشر مسار تعليمي؟ اضغط هنا

Performance of the PADME calorimeter prototype at the DA$Phi$NE BTF

78   0   0.0 ( 0 )
 نشر من قبل Mauro Raggi
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The PADME experiment at the DA$Phi$NE Beam-Test Facility (BTF) aims at searching for invisible decays of the dark photon by measuring the final state missing mass in the process $e^+e^- to gamma+ A$, with $A$ undetected. The measurement requires the determination of the 4-momentum of the recoil photon, performed using a homogeneous, highly segmented BGO crystals calorimeter. We report the results of the test of a 5$times$5 crystals prototype performed with an electron beam at the BTF in July 2016.



قيم البحث

اقرأ أيضاً

The PADME experiment at the DA$Phi$NE Beam-Test Facility (BTF) is designed to search for the gauge boson of a new $rm U(1)$ interaction in the process e$^+$e$^-rightarrowgamma$+$rm A$, using the intense positron beam hitting a light target. The $rm A $, usually referred as dark photon, is assumed to decay into invisible particles of a secluded sector and it can be observed by searching for an anomalous peak in the spectrum of the missing mass measured in events with a single photon in the final state. The measurement requires the determination of the 4-momentum of the recoil photon, performed by a homogeneous, highly segmented BGO crystals calorimeter. A significant improvement of the missing mass resolution is possible using an active target capable to determine the average position of the positron bunch with a resolution of less than 1 mm. This report presents the performance of a real size $rm (2x2 cm^2)$ PADME active target made of a thin (50 $mu$m) diamond sensor, with graphitic strips produced via laser irradiation on both sides. The measurements are based on data collected in a beam test at the BTF in November 2015.
The measurement of $BR(K^+topi^+ ubar{ u})$ with 10% precision by the NA62 experiment requires extreme background suppression. The Small Angle Calorimeter aims to provide an efficient veto for photons flying at angles down to zero with respect to the kaon flight direction. The initial prototype was upgraded and tested at the Beam Test Facility of the DA$Phi$NE Linac at Frascati. The energy resolution and the efficiency were measured and are presented.
The PADME experiment at the LNF Beam Test Facility searches for dark photons produced in the annihilation of positrons with the electrons of a fix target. The strategy is to look for the reaction $e^{+}+e^{-}rightarrow gamma+A$, where $A$ is the dark photon, which cannot be observed directly or via its decay products. The electromagnetic calorimeter plays a key role in the experiment by measuring the energy and position of the final-state $gamma$. The missing four-momentum carried away by the $A$ can be evaluated from this information and the particle mass inferred. This paper presents the design, construction, and calibration of the PADMEs electromagnetic calorimeter. The results achieved in terms of equalisation, detection efficiency and energy resolution during the first phase of the experiment demonstrate the effectiveness of the various tools used to improve the calorimeter performance with respect to earlier prototypes.
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test b eam at DESY with momenta between 1 and 6 GeV/c. The prototypes performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.
At the core of the AGILE scientific instrument, designed to operate on a satellite, there is the Gamma Ray Imaging Detector (GRID) consisting of a Silicon Tracker (ST), a Cesium Iodide Mini-Calorimeter and an Anti-Coincidence system of plastic scinti llator bars. The ST needs an on-ground calibration with a $gamma$-ray beam to validate the simulation used to calculate the energy response function and the effective area versus the energy and the direction of the $gamma$ rays. A tagged $gamma$-ray beam line was designed at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali of Frascati (LNF), based on an electron beam generating $gamma$ rays through bremsstrahlung in a position-sensitive target. The $gamma$-ray energy is deduced by difference with the post-bremsstrahlung electron energy cite{prest}-cite{hasan}. The electron energy is measured by a spectrometer consisting of a dipole magnet and an array of position sensitive silicon strip detectors, the Photon Tagging System (PTS). The use of the combined BTF-PTS system as tagged photon beam requires understanding the efficiency of $gamma$-ray tagging, the probability of fake tagging, the energy resolution and the relation of the PTS hit position versus the $gamma$-ray energy. This paper describes this study comparing data taken during the AGILE calibration occurred in 2005 with simulation.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا