ترغب بنشر مسار تعليمي؟ اضغط هنا

High-Intensity Synchrotron Radiation Effects

83   0   0.0 ( 0 )
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Y. Suetsugu




اسأل ChatGPT حول البحث

Various effects of intense synchrotron radiation on the performance of particle accelerators, especially for storage rings, are discussed. Following a brief introduction to synchrotron radiation, the basic concepts of heat load, gas load, electron emission, and the countermeasures against these effects are discussed.

قيم البحث

اقرأ أيضاً

Detrimental beam dynamics effects limit performance of high intensity rapid cycling synchrotrons (RCS) such as the 8 GeV proton Fermilab Booster. Here we report the results of comprehensive experimental studies of various beam intensity dependent eff ects in the Booster. In the first part, we report the dependencies of the Booster beam intensity losses on the total number of protons per pulse and on key operational parameters such as the machine tunes and chromaticities. Then we cross-check two methods of the beam emittance measurements (the multi-wires proportional chambers and the ionization profile monitors). Finally we used the intensity dependent emittance growth effects to analyze the ultimate performance of the machine in present configuration, with the maximum space-charge tuneshift parameter Qsc of 0.6, and after its injection energy is upgraded from 0.4 GeV to 0.8 GeV.
Beam quality preservation during transport of high-brightness electron beams is of general concern in the design of modern accelerators. Methods to manage incoherent synchrotron radiation (ISR) have been in place for decades; as beam brightness has i mproved coherent synchrotron radiation (CSR) and the microbunching instability (uBI) have emerged as performance limitations. We apply the compensation analysis of diMitri, Cornacchia, and Spampinati - as previously used by Borland - to the design of transport systems for use with low-emittance beams, and find that appropriately configured second order achromats will suppress transverse emittance growth due to CSR and appear to limit uBI gain.
60 - S.N. Ahmed 1999
A single channel, high precision ionization chamber has been built for monitoring the relative intensity of X-rays in the energy range above 5 keV. It can be used in experiments, such as EXAFS, where simultaneous high precision monitoring of the rela tive intensity during the actual experiment is required. In this paper the construction of the chamber and its performance during test measurements with an X-ray tube are presented.
The next generation of accelerators for Megawatt proton and heavy-ion beams moves us into a completely new domain of extreme specific energies of up to 0.1 MJ/g (Megajoule/gram) and specific power up to 1 TW/g (Terawatt/gram) in beam interactions wit h matter. This paper is focused on deleterious effects of controlled and uncontrolled impacts of high-intensity beams on components of beam-lines, target stations, beam absorbers, shielding and environment. Two new experiments at Fermilab are taken as an example. The Long-Baseline Neutrino Experiment (LBNE) will explore the interactions and transformations of the worlds highest-intensity neutrino beam by sending it from Fermilab more than 1,000 kilometers through the Earths mantle to a large liquid argon detector. The Mu2e experiment is devoted to studies of the conversion of a negative muon to electron in the field of a nucleus without emission of neutrinos.
153 - Junhao Tan , Yifei Li , Baojun Zhu 2019
Laser wakefield accelerators have emerged as a promising candidate for compact synchrotron radiation and even x-ray free electron lasers. Today, to make the electrons emit electromagnetic radiation, the trajectories of laser wakefield accelerated ele ctrons are deflected by transverse wakefield, counter-propagating laser field or external permanent magnet insertion device. Here, we propose a novel type of undulator which has a few hundred microns of period and tens of Tesla of magnetic field. The undulator consists of a bifilar capacitor-coil target which sustains strong discharge current that generates helical magnetic field around the coil axis when irradiated by a high energy laser. Coupling this undulator with state-of-the-art laser wakefield accelerators can, simultaneously, produce ultra-bright quasi-monochromatic x-rays with tunable energy ranging 5-250 keV and optimize the free electron laser parameter and gain length compared with permanent magnet based undulator. This concept may pave a path toward ultra-compact synchrotron radiation and even x-ray free electron lasers.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا