ترغب بنشر مسار تعليمي؟ اضغط هنا

Mitochondrial Ca2+ uptake in skeletal muscle health and disease

80   0   0.0 ( 0 )
 نشر من قبل Kamal Dhakal
 تاريخ النشر 2016
  مجال البحث علم الأحياء فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Muscle uses Ca2+ as a messenger to control contraction and relies on ATP to maintain the intracellular Ca2+ homeostasis. Mitochondria are the major sub-cellular organelle of ATP production. With a negative inner membrane potential, mitochondria take up Ca2+ from their surroundings, a process called mitochondrial Ca2+ uptake. Under physiological conditions, Ca2+ uptake into mitochondria promotes ATP production. Excessive uptake causes mitochondrial Ca2+ overload, which activates downstream adverse responses leading to cell dysfunction. Moreover, mitochondrial Ca2+ uptake could shape spatio-temporal patterns of intracellular Ca2+ signaling. Malfunction of mitochondrial Ca2+ uptake is implicated in muscle degeneration. Unlike non-excitable cells, mitochondria in muscle cells experience dramatic changes of intracellular Ca2+ levels. Besides the sudden elevation of Ca2+ level induced by action potentials, Ca2+ transients in muscle cells can be as short as a few milliseconds during a single twitch or as long as minutes during tetanic contraction, which raises the question whether mitochondrial Ca2+ uptake is fast and big enough to shape intracellular Ca2+ signaling during excitation-contraction coupling and creates technical challenges for quantification of the dynamic changes of Ca2+ inside mitochondria. This review focuses on characterization of mitochondrial Ca2+ uptake in skeletal muscle and its role in muscle physiology and diseases.



قيم البحث

اقرأ أيضاً

Shuttle-assisted charge transfer is pivotal for the efficient energy transduction from the food-stuff electrons to protons in the respiratory chain of animal cells and bacteria. The respiratory chain consists of four metalloprotein Complexes (I-IV) e mbedded in the inner membrane of a mitochondrion. Three of these complexes pump protons across the membrane, fuelled by the energy of food-stuff electrons. Despite extensive biochemical and biophysical studies, the physical mechanism of this proton pumping is still not well understood. Here we present a nanoelectromechanical model of the electron-driven proton pump related to the second loop of the respiratory chain, where a lipid-soluble ubiquinone molecule shuttles between the Complex I and Complex III, carrying two electrons and two protons. We show that the energy of electrons can be converted to the transmembrane proton potential gradient via the electrostatic interaction between electrons and protons on the shuttle. We find that the system can operate either as a proton pump, or, in the reverse regime, as an electron pump. For membranes with various viscosities, we demonstrate that the uphill proton current peaks near the body temperature $T approx 37 ^{circ}$C.
Mounting evidence for the role of oxidative stress in the degeneration of articular cartilage after an injurious impact requires our modeling & simulation efforts to temporarily shift from just describing the effect of mechanical stress and inflammat ion on osteoarthritis (OA). The hypothesis that the injurious impact causes irreversible damage to chondrocyte mitochondria, which in turn increase their production of free radicals, affecting their energy production and their ability to rebuild the extracellular matrix, has to be modeled and the processes quantified in order to further the understanding of OA, its causes, and viable treatment options. The current article presents a calibrated model that captures the damage oxidative stress incurs on the cell viability, ATP production, and cartilage stability in a cartilage explant after a drop-tower impact. The model validates the biological hypothesis and will be used in further efforts to identify possibilities for treatment and be a part of a bigger modeling & simulation framework for the development of OA.
Intracellular pathogens such as Listeria monocytogenes and Rickettsia rickettsii move within a host cell by polymerizing a comet-tail of actin fibers that ultimately pushes the cell forward. This dense network of cross-linked actin polymers typically exhibits a striking curvature that causes bacteria to move in gently looping paths. Theoretically, tail curvature has been linked to details of motility by considering force and torque balances from a finite number of polymerizing filaments. Here we track beads coated with a prokaryotic activator of actin polymerization in three dimensions to directly quantify the curvature and torsion of bead motility paths. We find that bead paths are more likely to have low rather than high curvature at any given time. Furthermore, path curvature changes very slowly in time, with an autocorrelation decay time of 200 seconds. Paths with a small radius of curvature, therefore, remain so for an extended period resulting in loops when confined to two dimensions. When allowed to explore a 3D space, path loops are less evident. Finally, we quantify the torsion in the bead paths and show that beads do not exhibit a significant left- or right-handed bias to their motion in 3D. These results suggest that paths of actin-propelled objects may be attributed to slow changes in curvature rather than a fixed torque.
100 - Peng Zou 2014
We present a palette of brightly fluorescent genetically encoded voltage indicators (GEVIs) with excitation and emission peaks spanning the visible spectrum, sensitivities from 6 - 10% Delta F/F per 100 mV, and half-maximal response times from 1 - 7 ms. A fluorescent protein is fused to an Archaerhodopsin-derived voltage sensor. Voltage-induced shifts in the absorption spectrum of the rhodopsin lead to voltage-dependent nonradiative quenching of the appended fluorescent protein. Through a library screen, we identified linkers and fluorescent protein combinations which reported neuronal action potentials in cultured rat hippocampal neurons with a single-trial signal-to-noise ratio from 6.6 to 11.6 in a 1 kHz imaging bandwidth at modest illumination intensity. The freedom to choose a voltage indicator from an array of colors facilitates multicolor voltage imaging, as well as combination with other optical reporters and optogenetic actuators.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا