Analogue to Digital and Digital to Analogue Converters (ADCs and DACs): A Review Update

66   0   0.0 ( 0 )
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English
 تأليف J. Pickering




اسأل ChatGPT حول البحث

This is a review paper updated from that presented for CAS 2004. Essentially, since then, commercial components have continued to extend their performance boundaries but the basic building blocks and the techniques for choosing the best device and implementing it in a design have not changed. Analogue to digital and digital to analogue converters are crucial components in the continued drive to replace analogue circuitry with more controllable and less costly digital processing. This paper discusses the technologies available to perform in the likely measurement and control applications that arise within accelerators. It covers much of the terminology and specmanship together with an application-oriented analysis of the realisable performance of the various types. Finally, some hints and warnings on system integration problems are given.

قيم البحث

اقرأ أيضاً

The influence on $gamma$-ray spectra of differential nonlinearities (DNL) in subranging, pipelined analog-to-digital converts (ADCs) used for digital $gamma$-ray spectroscopy was investigated. The influence of the DNL error on the $gamma$-ray spectra , depending on the input count-rate and the dynamic range has been investigated systematically. It turned out, that the DNL becomes more significant in $gamma$-ray spectra with larger dynamic range of the spectroscopy system. An event-by-event offline correction algorithm was developed and tested extensively. This correction algorithm works especially well for high dynamic ranges.
A novel radio guided surgery (RGS) technique for cerebral tumors using $beta^{-}$ radiation is being developed. Checking the availability of a radio-tracer that can deliver a $beta^{-}$ emitter to the tumor is a fundamental step in the deployment of such technique. This paper reports a study of the uptake of 90Y labeled (DOTATOC) in the meningioma and the high grade glioma (HGG) and a feasibility study of the RGS technique in these cases.
110 - G. Puhlhofer 2012
The future Cherenkov Telescope Array (CTA) will consist of several tens of telescopes of different mirror sizes. CTA will provide next generation sensitivity to very high energy photons from few tens of GeV to >100 TeV. Several focal plane instrument ation options are currently being evaluated inside the CTA consortium. In this paper, the current status of the FlashCam prototyping project is described. FlashCam is based on a fully digital camera readout concept and features a clean separation between photon detector plane and signal digitization/triggering electronics.
Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator detector, and a BaF2 detector was used to collect waveforms with a 100 Ms/s, 14 bit sampling ADC. Three identical ADCs were combined to increase the sampling frequency to 300 Ms/s. Four different digital pulse-shape analysis algorithms were developed and compared to each other and to data obtained with an analogue neutron-gamma discrimination unit. Two of the digital algorithms were based on the charge comparison method, while the analogue unit and the other two digital algorithms were based on the zero-crossover method. Two different figure-of-merit parameters, which quantify the neutron-gamma discrimination properties, were evaluated for all four digital algorithms and for the analogue data set. All of the digital algorithms gave similar or better figure-of-merit values than what was obtained with the analogue setup. A detailed study of the discrimination properties as a function of sampling frequency and bit resolution of the ADC was performed. It was shown that a sampling ADC with a bit resolution of 12 bits and a sampling frequency of 100 Ms/s is adequate for achieving an optimal neutron-gamma discrimination for pulses having a dynamic range for deposited neutron energies of 0.3-12 MeV. An investigation of the influence of the sampling frequency on the time resolution was made. A FWHM of 1.7 ns was obtained at 100 Ms/s.
331 - V. Grabski 2009
Here an image restoration on the basis of pixel simultaneous detection probabilities (PSDP) is proposed. These probabilities can be precisely determined by means of correlations measurement [NIMA 586 (2008) 314-326]. The proposed image restoration is based on the solution of matrix equation. Non-zero elements of Toeplitz block matrix with ones on the main diagonal, is determined using PSDP. The number of non zero descending diagonals depends on the detector construction and is not always smaller than 8. To solve the matrix equation, the Gaussian elimination algorithm is used. The proposed restoration algorithm is studied by means of the simulated images (with and without additive noise using PSDP for General Electric Senographe 2000D mammography device detector) and a small area (160x160 pixels) of real images acquired by the above mentioned device. The estimation errors of PSDP and the additive noise magnitude permits to restore images with the precision better than 3% for the above mentioned detector. The additive noise in the real image is present after restoration and almost has the same magnitude. In the restored small area (16x16 mm) of real images, the pixel responses are not correlated. The spatial resolution improvement is also analyzed by the image of an absorber edge.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا