A laser diode based system for calibration of fast time-of-flight detectors

71   0   0.0 ( 0 )
 نشر من قبل Maurizio Bonesini M.
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A system based on commercially available items, such as a laser diode, emitting in the visible range $sim 400$ nm,and multimode fiber patches, fused fiber splitters and optical switches may be assembled,for time calibration of multi-channels time-of-flight (TOF) detectors with photomultipliers (PMTs) readout. As available laser diode sources have unfortunately limited peak power, the main experimental problem is the tight light power budget of such a system. In addition, while the technology for fused fiber splitters is common in the Telecom wavelength range ($lambda sim 850, 1300-1500$ nm), it is not easily available in the visible one. Therefore, extensive laboratory tests had to be done on purpose, to qualify the used optical components, and a full scale timing calibration prototype was built. Obtained results show that with such a system, a calibration resolution ($sigma$) in the range 20-30 ps may be within reach. Therefore, fast multi-channels TOF detectors, with timing resolutions in the range 50-100 ps, may be easily calibrated in time. Results on tested optical components may be of interest also for time calibration of different light detection systems based on PMTs, as the ones used for detection of the vacuum ultraviolet scintillation light emitted by ionizing particles in large LAr TPCs.

قيم البحث

اقرأ أيضاً

A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the las er system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neutron Detector (BAND) scintillator array. The system successfully provided time walk corrections, absolute time calibration, and TOF drift correction for the scintillators in BAND. This showcases the general applicability of the system for use on high-precision TOF detectors.
We have developed a new laser-based time calibration system for the MEG II timing counter dedicated to timing measurement of positrons. The detector requires precise timing alignment between $sim,$500 scintillation counters. In this study, we present the calibration system which can directly measure the time offset of each counter relative to the laser-synchronized pulse. We thoroughly tested all the optical components and the uncertainty of this method is estimated to be 24 ps. In 2017, we installed the full system into the MEG II environment and performed a commissioning run. This method shows excellent stability and consistency with another method. The proposed system provides a precise timing alignment for SiPM-based timing detectors. It also has potential in areas such as TOF-PET.
We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon photomultipliers (SiPM s). It is difficult to apply previous laser-based calibration methods for conventional meter-scale Time-Of-Flight detectors to the MEG II pTC from the implementation and the accuracy points of view. This paper presents a new laser-based time calibration system which can overcome such difficulties. A laser pulse is split into each scintillator counter via several optical components so that we can directly measure the time offset of each counter relative to the laser-emitted time. We carefully tested all the components and procedures prior to the actual operation. The laser system was installed into the pTC and thoroughly tested under the real experimental condition. The system showed good stability and being sensitive to any change of timing larger than ~10 ps. Moreover, it showed an uncertainty of 48 ps in the determination of the time offsets, which meets our requirements. The new method provides an example of the implementation of a precise timing alignment for the new type of detectors enabled by the advance of SiPM technology.
A number of liquid argon time projection chambers (LAr TPCs) are being build or are proposed for neutrino experiments on long- and short baseline beams. For these detectors a distortion in the drift field due to geometrical or physics reasons can aff ect the reconstruction of the events. Depending on the TPC geometry and electric drift field intensity this distortion could be of the same magnitude as the drift field itself. Recently, we presented a method to calibrate the drift field and correct for these possible distortions. While straight cosmic ray muon tracks could be used for calibration, multiple coulomb scattering and momentum uncertainties allow only a limited resolution. A UV laser instead can create straight ionization tracks in liquid argon, and allows one to map the drift field along different paths in the TPC inner volume. Here we present a UV laser feed-through design with a steerable UV mirror immersed in liquid argon that can point the laser beam at many locations through the TPC. The straight ionization paths are sensitive to drift field distortions, a fit of these distortion to the linear optical path allows to extract the drift field, by using these laser tracks along the whole TPC volume one can obtain a 3D drift field map. The UV laser feed-through assembly is a prototype of the system that will be used for the MicroBooNE experiment at the Fermi National Accelerator Laboratory (FNAL).
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD ) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below the junction. The UFSD used in this test belongs to the first production of thin (50 {mu}m) sensors, with an pad area of 1.4 mm2. The gain was measured to vary between 5 and 70 depending on the bias voltage. The experimental setup included three UFSD and a fast trigger consisting of a quartz bar readout by a SiPM. The timing resolution, determined comparing the time of arrival of the particle in one or more UFSD and the trigger counter, for single UFSD was measured to be 35 ps for a bias voltage of 200 V, and 26 ps for a bias voltage of 240 V, and for the combination of 3 UFSD to be 20 ps for a bias voltage of 200 V, and 15 ps for a bias voltage of 240 V.