ترغب بنشر مسار تعليمي؟ اضغط هنا

First results of the new endcap TOF commissioning at BESIII

81   0   0.0 ( 0 )
 نشر من قبل Zhi Wu
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The upgrade of the current BESIII Endcap TOF (ETOF) is carried out with the Multi-gap Resistive Plate Chamber (MRPC) technology. The installation of the new ETOF has been finished in October 2015. The first results of the MRPCs commissioning at BESIII are reported in this paper.

قيم البحث

اقرأ أيضاً

83 - M. Ullrich , W. Kuhn , Y. Liang 2014
The results of a full simulation of an endcap Time-of-Flight detector upgrade based on multigap resistive plate chambers for the BESIII experiment are presented. The simulation and reconstruction software is based on Geant4 and has been implemented i nto the BESIII Offline Software System. The results of the simulations are compared with beam test results and it is shown that a total time resolution $sigma$ of about 80 ps can be achieved allowing for a pion and kaon separation up to momenta of 1.4 GeV/c at a 95% confidence level.
The Cylindrical GEM-Inner Tracker (CGEM-IT) is the upgrade of the internal tracking system of the BESIII experiment. It consists of three layers of cylindrically-shaped triple GEMs, with important innovations with respect to the existing GEM detector s, in order to achieve the best performance with the lowest material budget. It will be the first cylindrical GEM running with analog readout inside a 1T magnetic field. The simultaneous measurement of both the deposited charge and the signal time will permit to use a combination of two algorithms to evaluate the spatial position of the charged tracks inside the CGEM-IT: the charge centroid and the micro time projection chamber modes. They are complementary and can cope with the asymmetry of the electron avalanche when running in magnetic field and with non-orthogonal incident tracks. To evaluate the behavior under different working settings, both planar chambers and the first cylindrical prototype have been tested during various test beams at CERN with 150 GeV/c muons and pions. This paper reports the results obtained with the two reconstruction methods and a comparison between the planar and cylindrical chambers.
The Argon Dark Matter experiment is a ton-scale double phase argon Time Projection Chamber designed for direct Dark Matter searches. It combines the detection of scintillation light together with the ionisation charge in order to discriminate the bac kground (electron recoils) from the WIMP signals (nuclear recoils). After a successful operation on surface at CERN, the detector was recently installed in the underground Laboratorio Subterraneo de Canfranc, and the commissioning phase is ongoing. We describe the status of the installation and present first results from data collected underground with the detector filled with gas argon at room temperature.
Three new sub-detectors have been installed on May 2013 in the KLOE apparatus of Laboratori Nazionali di Frascati of INFN. Photon detection is improved by means of a small crystal calorimeter, named CCALT, in the very forward direction and of a tungs ten-scintillating tile sampling device, named QCALT, instrumenting the low-beta quadrupoles of the accelerator. During the first DA$phi$NE operations, some preliminary runs, both with and without collisions, have been acquired allowing the commissioning of new subdetectors. In this paper, we report a brief description of QCALT and CCALT and a summary of the commissioning phase.
In order to fully reconstruct the gamma gamma processes (e+e- -> e+e- gamma gamma) in the energy region of the phi meson production, new detectors along the DAFNE beam line have been installed in order to detect the scattered e+e-.