ترغب بنشر مسار تعليمي؟ اضغط هنا

ArDM: first results from underground commissioning

141   0   0.0 ( 0 )
 نشر من قبل Filippo Resnati
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Argon Dark Matter experiment is a ton-scale double phase argon Time Projection Chamber designed for direct Dark Matter searches. It combines the detection of scintillation light together with the ionisation charge in order to discriminate the background (electron recoils) from the WIMP signals (nuclear recoils). After a successful operation on surface at CERN, the detector was recently installed in the underground Laboratorio Subterraneo de Canfranc, and the commissioning phase is ongoing. We describe the status of the installation and present first results from data collected underground with the detector filled with gas argon at room temperature.

قيم البحث

اقرأ أيضاً

The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr. After successful operation on surface at CERN, the detector has been deployed underground and is presently commissioned at the Canfranc Underground Laboratory (LSC). In this paper, we describe the status of the installation and present first results on data collected in gas phase.
66 - J. Belfi , N. Beverini , F. Bosi 2016
Large ring-laser gyroscopes are capable of measuring angular rotations with a precision well below fractions of $prad/s$, not far from $10^{-14}$ $rad/s$, the accuracy required for General Relativity tests, this is what the GINGER (Gyroscope-IN-GEner al-Relativity) experiment is aiming for. These features do not guarantee the possibility of measuring the General Relativity Lense--Thirring effect, that manifests itself as a tiny ($approx 10^{-9} times Omega_E$) perturbation of the Earth rotation rate. An underground location being in principle less affected by external local disturbances represents a good candidate for housing such a challenging experiment. GINGERino is a test apparatus to investigate the residual local disturbances in the most inner part of the underground international laboratory of the GranSasso (LNGS). It consists of a square ring laser with a $3.6$ m side. The instrument has been tailored to be the larger allowed by the particular location inside the laboratory. Its main objective is to measure the very low frequency rotational motions, in order to prove that LNGS is a suitable location for very low noise measurements and, possibly, General Relativity tests. Aside this main goal, GINGERino will provide unique data for geodesy and geophysics. Its installation has been completed during 2015. Since then, several long set of data have been collected, and the apparatus has been continuously running unattended for more than one week. The typical power spectrum sensitivity was a few $ 10^{-10} rad/s/sqrt(Hz)$, with integration time not longer than tens of seconds. Improvements of the apparatus are ongoing in order to improve the integration time.
ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30,keVr to detect recoi ling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM on the surface at CERN. With a preliminary and incomplete set of PMTs, the light yield at zero electric field is found to be between 0.3-0.5 phe/keVee depending on the position within the detector volume, confirming our expectations based on smaller detector setups.
The upgrade of the current BESIII Endcap TOF (ETOF) is carried out with the Multi-gap Resistive Plate Chamber (MRPC) technology. The installation of the new ETOF has been finished in October 2015. The first results of the MRPCs commissioning at BESIII are reported in this paper.
A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ~35 cm drift $times$ 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a s ectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume (~23 l) so as to contain long (~20 cm) electron tracks. First results obtained at 1 bar for Xenon and trimethylamine (Xe-(2 %)TMA) mixture are presented. The TPC can accurately reconstruct extended background tracks. An encouraging full-width half-maximum of 11.6 % was obtained for ~29 keV gammas without resorting to any data post-processing.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا