ترغب بنشر مسار تعليمي؟ اضغط هنا

Gaseous time projection chambers for rare event detection: Results from the T-REX project. II. Dark matter

65   0   0.0 ( 0 )
 نشر من قبل Igor G. Irastorza
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

As part of the T-REX project, a number of R&D and prototyping activities have been carried out during the last years to explore the applicability of Micromegas-read gaseous TPCs in rare event searches like double beta decay (DBD), axion research and low-mass WIMP searches. While in the companion paper we focus on DBD, in this paper we focus on the results regarding the search for dark matter candidates, both axions and WIMPs. Small ultra-low background Micromegas detectors are used to image the x-ray signal expected in axion helioscopes like CAST at CERN. Background levels as low as $0.8times 10^{-6}$ c keV$^{-1}$cm$^{-2}$s$^{-1}$ have already been achieved in CAST while values down to $sim10^{-7}$ c keV$^{-1}$cm$^{-2}$s$^{-1}$ have been obtained in a test bench placed underground in the Laboratorio Subterraneo de Canfranc. Prospects to consolidate and further reduce these values down to $sim10^{-8}$ c keV$^{-1}$cm$^{-2}$s$^{-1}$will be described. Such detectors, placed at the focal point of x-ray telescopes in the future IAXO experiment, would allow for 10$^5$ better signal-to-noise ratio than CAST, and search for solar axions with $g_{agamma}$ down to few 10$^{12}$ GeV$^{-1}$, well into unexplored axion parameter space. In addition, a scaled-up version of these TPCs, properly shielded and placed underground, can be competitive in the search for low-mass WIMPs. The TREX-DM prototype, with $sim$0.300 kg of Ar at 10 bar, or alternatively $sim$0.160 kg of Ne at 10 bar, and energy threshold well below 1 keV, has been built to test this concept. We will describe the main technical solutions developed, as well as the results from the commissioning phase on surface. The anticipated sensitivity of this technique might reach $sim10^{-44}$ cm$^2$ for low mass ($<10$ GeV) WIMPs, well beyond current experimental limits in this mass range.

قيم البحث

اقرأ أيضاً

As part of the T-REX project, a number of R&D and prototyping activities have been carried out during the last years to explore the applicability of gaseous Micromegas-read TPCs in rare event searches like double beta decay (DBD), axion research and low-mass WIMP searches. In both this and its companion paper, we compile the main results of the project and give an outlook of application prospects for this detection technique. While in the companion paper we focus on axions and WIMPs, in this paper we focus on the results regarding the measurement of the DBD of $^{136}$Xe in a high pressure Xe (HPXe) TPC. Particularly relevant are the results obtained in Xe + TMA mixtures with microbulk Micromegas, showing very promising results in terms of gain, stability of operation, and energy resolution at pressures up to 10 bar. TMA at levels of $sim$1% reduces electron diffusion by a factor of 10 with respect to pure Xe, improving the quality of the topological pattern, with a positive impact on the discrimination capability. Operation with a medium size prototype (30 cm diameter and 38 cm drift) of 1 kg of Xe at 10 bar in the fiducial volumen has allowed to test the detection concept in realistic experimental conditions. Microbulk Micromegas are able to image the DBD ionization signature with high quality while, at the same time, measuring its energy deposition with a resolution of at least $sim$3% FWHM @ Q$_{betabeta}$, and probably down to $sim$1% FWHM. In addition, first results on the topological signature information show promising background discrimination capabilities out of reach of other experimental implementations. Moreover, microbulk Micromegas have very low levels of intrinsic radioactivity, and offer cost-effective scaling-up options. All these results demonstrate that Micromegas-read HPXe TPC is a very competitive technique for the next generation DBD experiments.
In this paper we explore the potential improvements in neutrino event reconstruction that a 3D pixelated readout could offer over a 2D projective wire readout for liquid argon time projection chambers. We simulate and study events in two generic, ide alized detector configurations for these two designs, classifying events in each sample with deep convolutional neural networks to compare the best 2D results to the best 3D results. In almost all cases we find that the 3D readout provides better reconstruction efficiency and purity than the 2D projective wire readout, with the advantages of 3D being particularly evident in more complex topologies, such as electron neutrino charged current events. We conclude that the use of a 3D pixelated detector could significantly enhance the reach and impact of future liquid argon TPC experiments physics program, such as DUNE.
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volu me demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg, $^{232}$Th$_{e}$~$=0.28pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25pm 0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of $0.160pm0.001$(stat)$pm0.030$(sys) counts.
We present a novel electrical technique to measure the tension of wires in multi-wire drift chambers. We create alternating electric fields by biasing adjacent wires on both sides of a test wire with a superposition of positive and negative DC voltag es on an AC signal ($V_{rm AC} pm V_{rm DC}$). The resulting oscillations of the wire will display a resonance at its natural frequency, and the corresponding change of the capacitance will lead to a measurable current. This scheme is scalable to multiple wires and therefore enables us to precisely measure the tension of a large number of wires in a short time. This technique can also be applied at cryogenic temperatures making it an attractive solution for future large time-projection chambers such as the DUNE detector. We present the concept, an example implementation and its performance in a real-world scenario and discuss the limitations of the sensitivity of the system in terms of voltage and wire length.
A number of liquid argon time projection chambers (LAr TPCs) are being build or are proposed for neutrino experiments on long- and short baseline beams. For these detectors a distortion in the drift field due to geometrical or physics reasons can aff ect the reconstruction of the events. Depending on the TPC geometry and electric drift field intensity this distortion could be of the same magnitude as the drift field itself. Recently, we presented a method to calibrate the drift field and correct for these possible distortions. While straight cosmic ray muon tracks could be used for calibration, multiple coulomb scattering and momentum uncertainties allow only a limited resolution. A UV laser instead can create straight ionization tracks in liquid argon, and allows one to map the drift field along different paths in the TPC inner volume. Here we present a UV laser feed-through design with a steerable UV mirror immersed in liquid argon that can point the laser beam at many locations through the TPC. The straight ionization paths are sensitive to drift field distortions, a fit of these distortion to the linear optical path allows to extract the drift field, by using these laser tracks along the whole TPC volume one can obtain a 3D drift field map. The UV laser feed-through assembly is a prototype of the system that will be used for the MicroBooNE experiment at the Fermi National Accelerator Laboratory (FNAL).